THE REAL-TIME VIZUALIZATION OF PNEUMOGRAM SIGNALS
The real-time visualization of pneumogram signals is described in this contribution. The device created provides simultaneous measurement of pneumogram and voice. The sampled signals are transmitted to PC software in real time via USB bus, which makes it possible to show the curves from the sampled signals in real-time. In addition, data archiving and printing functions are integrated into the software. Since pneumography is one of the oldest methods to provide information about the technique of respiration, it will be possible for doctors in phoniatric practice to use the created device and programmed application for patient diagnosis. Listed in the results is an example of the recordings acquired from the designed device.
Keywords:
pneumography, pneumogram, phoniatry, diagnostics, real-time signal processing, visualization
Autoři:
Jan Sedlák 1; Roman Čmejla 1
Působiště autorů:
Department of Circuit Theory, Faculty of Electrical Engineering, CTU in Prague
1
Vyšlo v časopise:
Lékař a technika - Clinician and Technology No. 2, 2012, 42, 89-91
Kategorie:
Conference YBERC 2012
Souhrn
The real-time visualization of pneumogram signals is described in this contribution. The device created provides simultaneous measurement of pneumogram and voice. The sampled signals are transmitted to PC software in real time via USB bus, which makes it possible to show the curves from the sampled signals in real-time. In addition, data archiving and printing functions are integrated into the software. Since pneumography is one of the oldest methods to provide information about the technique of respiration, it will be possible for doctors in phoniatric practice to use the created device and programmed application for patient diagnosis. Listed in the results is an example of the recordings acquired from the designed device.
Keywords:
pneumography, pneumogram, phoniatry, diagnostics, real-time signal processing, visualization
Zdroje
[1] NOVÁK, A. Foniatrie a pedaudologie II. Poruchy hlasu u dětí a dospělých - základy anatomie a fyziologie hlasu, diagnostika, léčba, reedukace a rehabilitace poruch hlasu. Praha: UNITISK, 2000.
[2] JANÍKOVÁ, D. Fyzioterapia funkčná diagnostika lokomočného systému. Martin: Osvěta, 1998, s. 238. ISBN 80- 8063-015-1.
[3] HAASZ, V. - SEDLÁČEK, M.: Elektrická měření. Přístroje a metody (2. vydání). Monografie ČVUT, Praha 2003
[4] The cheapest dual trace scope in the galaxy [online]. 2012 [cit. 2012-04-25]. Dostupné z WWW: <http://yveslebrac.blogspot. com/2008/10/cheapest-dual-trace-scope-in-galaxy.html>.
[5] Biopac Respiratory-effort-transducer SS5LB [online]. 2012 [cit. 2012-04-25]. Dostupné z WWW: <http://www.biopac.com/ respiratory-effort-transducer-bsl>.
[6] Microsoft PictureBox class [online]. 2012 [cit. 2012-04-25]. Dostupné z WWW: <http://msdn.microsoft.com/en-us/library/ system.windows.forms.picturebox.aspx>.
[7] Atmel Inc. AT91SAM7S64 datasheet [online]. 2012 [cit. 2012-04-25]. Dostupné z WWW: <http://www.alldatasheet.com/ datasheet-pdf/pdf/255484/ATMEL/AT91SAM7S64.html>.
Štítky
BiomedicínaČlánok vyšiel v časopise
Lékař a technika
2012 Číslo 2
Najčítanejšie v tomto čísle
- MECHANICAL MODEL OF THE CARDIOVASCULAR SYSTEM: DETERMINATION OF CARDIAC OUTPUT BY DYE DILUTION
- MATLAB AND ITS USE FOR PROCESSING OF THERMOGRAMS
- VENTILATOR CIRCUIT MODEL FOR OPTIMIZATION OF HIGH-FREQUENCY OSCILLATORY VENTILATION
- The Fifth Biomedical Engineering Conference of Young Biomedical Engineers and Researchers