Advances in mechanical ventilation in children
Authors:
M. Fedora
Published in the journal:
Anest. intenziv. Med., 19, 2008, č. 1, s. 16-18
Category:
Intensive Medicine
Summary
Mechanical ventilation is a common intervention provided in paediatric intensive care units. The management of mechanical ventilation in paediatrics is guided by a limited number of paediatric trials along with the application of adult data. Mechanical ventilation with pressure limitation and low tidal volume has become customary in paediatric intensive care. High frequency oscillatory ventilation is considered a suitable method to ‘open the lung’ and certainly is a lung-protective approach. Further research of noninvasive ventilation, prone positioning, the surfactant and weaning support to assist the paediatric intensivists in the application of these therapies is warranted.
Keywords:
children – mechanical ventilation
Zdroje
1. Randolph, A. G., Meert, K. L., O’Neil, M. E. et al. The feasibility of conducting clinical trials in infants and children with acute respiratory failure. Am. J. Respir.Crit. Care Med., 2003, 167, p. 1334–1340.
2. Turner, D. A., Arnold, J. H. Insights in pediatric ventilation: timing of intubation, ventilatory strategies, and weaning. Current
Opinion in Critical Care, 2007, 13, p. 57–63.
3. Piastra, M., Antonelli, M., Caresta, E. et al. Noninvasive ventilation in childhood acute neuromuscular respiratory failure:
a pilot study. Respiration, 2006, 16 (Epub ahead of print).
4. Essouri, S., Nicot, F., Clement, A. et al. Noninvasive positive pressure ventilation in infants with upper airway obstruction:
comparison of continuous and bilevel positive pressure. Intensive Care Med., 2005, 31, p. 574–580.
5. Carroll, C. L., Schramm, C. M. Noninvasive positive pressure ventilation for the treatment of status asthmaticus in children.
Ann. Allergy Asthma Immunol., 2006, 96, p. 454–459.
6. Madden, B. P., Kariyawasam, H., Siddiqi, A. J. et al. Non- invasive ventilation in cystic fibrosis patients with acute or chronic
respiratory failure. Eur. Respir. J., 2002, 19, p. 310– 313.
7. Villar, J., Kacmarek, R. M., Perez-Mendez, L. et al. A high positive endexpiratory pressure, low tidal volume ventilatory
strategy improves outcome in persistent acute respiratory distress syndrome: a randomized, controlled trial.Crit. Care
Med., 2006, 34, p. 1311–1318.
8. Arnold, J. H., Hanson, J. H., Toro-Figuero, L. O. et al. Prospective, randomized comparison of high-frequency oscillatory
ventilation and conventional mechanical ventilation in pediatric respiratory failure.Crit. Care Med., 1994, 22,
p. 1530–1539.
9. Mehta, S., Granton. J,, MacDonald, R. J. et al. High-frequency oscillatory ventilation in adults: the Toronto experience.
Chest, 2004, 126, p. 518–527.
10. Dani, C., Bertini, G., Pezzati, M. et al. Effects of pressure support ventilation plus volume guarantee vs high-frequency oscillatory
ventilation on lung inflammation in preterm infants. Pediatr. Pulmonol., 2006, 41, p. 242–249.
11. Jaballah, N. B., Khaldi, A., Mnif, K. et al. High-frequency oscillatory ventilation in pediatric patients with acute respiratory
failure. Pediatr. Crit. Care Med., 2006, 7, p. 362–367.
12. Curley, M. A., Hibberd, P. L., Fineman, L. D. et al. Effect of prone positioning on clinical outcomes in children with acute lung injury: a randomized controlled trial. JAMA, 2005, 294, p. 229–237.
13. Mancebo, J., Fernandez, R., Blanch, L. et al. A multicenter trial of prolonged prone ventilation in severe acute respiratory
distress syndrome. Am. J. Respir.Crit. Care Med., 2006, 173, p. 1233–1239.
14. Spragg, R. G., Lewis, J. F., Walmrath, H. D. et al. Effect of recombinant surfactant protein C-based surfactant on the acute
respiratory distress syndrome. N. Engl. J. Med., 2004, 351, p. 884–892.
15. Willson, D. F., Thomas, N. J., Markovitz, B. P. et al. Effect of exogenous surfactant (calfactant) in pediatric acute lung injury:
a randomized controlled trial. JAMA, 2005, 293, p. 470–476.
16. Randolph, A. G., Wypij, D., Venkataraman, S. T. et al. Effect of mechanical ventilator weaning protocols on respiratory
outcomes in infants and children: a randomized controlled trial. JAMA, 2002, 288, p. 2561–2568.
17. Schultz, T. R., Lin, R. J., Watzman, H. M. et al.Weaning children from mechanical ventilation: a prospective randomized trial
of protocol-directed versus physician-directed weaning. Respir. Care, 2001, 46, p. 772–782.
18. Restrepo, R. D., Fortenberry, J. D., Spainhour, C. et al. Protocol- driven ventilator management in children: comparison
to nonprotocol care. J. Intensive Care Med., 2004, 19, p. 274–284.
19. Baisch, S. D., Wheeler, W. B., Kurachek, S. C. et al. Extubation failure in pediatric intensive care incidence and outcomes.
Pediatr. Crit. Care Med., 2005, 6, p. 312–318.
20. Fontela, P. S., Piva, J. P., Garcia, P. C. et al. Risk factors for extubation failure in mechanically ventilated pediatric patients.
Pediatr. Crit. Care Med., 2005, 6, p. 166–170.
21. Randolph, A. G., Forbes, P. W., Gedeit, R. G. et al. Cumulative fluid intake minus output is not associated with ventilator
weaning duration or extubation outcomes in children. Pediatr. Crit. Care Med., 2005, 6, p. 642–647.
22. Foland, J. A., Super, D. M., Dahdah, N. S. et al. The use of
the air leak test and corticosteroids in intubated children: a survey of pediatric critical care fellowship directors. Respir. Care, 2002, 47, p. 662–666.
23. Mhanna, M. J., Zamel, Y. B., Tichy, C. M. et al. The ‘air leak’ test around the endotracheal tube, as a predictor of postextubation
stridor, is age dependent in children. Crit. Care Med., 2002, 30, p. 2639–2643.
24. Suominen, P., Taivainen, T., Tuominen, N. et al. Optimally fitted trachea tubes decrease the probability of postextubation
adverse events in children undergoing general anesthesia. Paediatr. Anaesth., 2006, 16, p. 641–647.
25. Lukkassen, I. M., Hassing, M. B., Markhorst, D. G. Dexamethasone reduces reintubation rate due to postextubation
stridor in a high-risk paediatric population. Acta Paediatr., 2006, 95, p. 74–76.
26. Cheng, K. C., Hou, C. C., Huang, H. C. et al. Intravenous injection of methylprednisolone reduces the incidence of postextubation stridor in intensive care unit patients. Crit. Care Med., 2006, 34, p. 1345–1350.
Štítky
Anaesthesiology, Resuscitation and Inten Intensive Care MedicineČlánok vyšiel v časopise
Anaesthesiology and Intensive Care Medicine
2008 Číslo 1
Najčítanejšie v tomto čísle
- The management of severe acute pancreatitis – state of the art
- Polyneuropathy and myopathy of critically ill patients – what’s new?
- Current treatment of sepsis in children
- Blood purification and acute renal failure: the timing, method selection and dosing of renal replacement therapy