Determination of Carbohydrate Deficient Transferrin (CDT) by various analytical techniques
Authors:
P. Kušnierová 1,2; V. Bartoš 1,2; Z. Vavřina 2; M. Polok Rajska 3; P. Loučka 3; F. Všianský 1; D. Zeman 1,2; Z. Švagera 1,2; K. Šafarčík 1,2
Authors place of work:
Ústav laboratorní diagnostiky, Oddělení klinické biochemie, Fakultní nemocnice Ostrava
1; Katedra biomedicínských oborů, Lékařská fakulta, Ostravská univerzita
2; SPADIA Lab, a. s.
3
Published in the journal:
Klin. Biochem. Metab., 26, 2018, No. 1, p. 35-40
Summary
Objective:
Determination of CDT by various analytical methods to find the most suitable alternative for the originally used HPLC system.
Type:
Methodical study.
Material and methods:
140 samples of patients from various specialized ambulances of the Moravian-Silesian Region with suspicion of alcohol abuse were included in the study. The CDT assay was performed according to validated procedures on the analytical systems: Variant (HPLC, Bio-Rad), MINICAP (Capillary Electrophoresis, Sebia) and BN ProSpec (Immunonephelometry, Siemens Healthineers). For statistical analysis, program Excel and MedCalc Version 16.1.2 were used.
Results:
Determination of CDT levels on analytical systems BN ProSpec, Variant and MINICAP, were verified. We evaluated the precision of the measurement under repeatability conditions, the lowest coefficient of variation (CV) was obtained on BN ProSpec, (CV 2.17 - 5.10%), and simultaneously the smallest deviation from declared values of commercial control materials at both levels (0.38% and 0.86%). Using the Passing Bablok regression, the best conformity was detected between Variant vs. MINICAP (y = 0.466 + 1.128 x). BN ProSpec reported the largest proportional error among systems. Using the Bland-Altman differential graphs the growing values of Bias were found in all three mutual comparisons, where the BN ProSpec provides lower concentrations of CDT% at higher concentrations than other systems. Kappa statistics confirmed that the best diagnostic conformity between systems provides Variant vs. MINICAP (0.851), the worst between systems Variant vs. BN ProSpec (0.696).
Conclusion:
BN ProSpec showed the best results of precision and accuracy of measurement. Kappa statistics demonstrated a very good conformity between Variant and MINICAP, respectively BN ProSpec analyzers. Nevertheless, BN ProSpec is due to simple, quick and trouble-free determination the most suitable replacement for the existing previously used analytical system Variant.
Keywords:
carbohydrate-deficient transferrin, high-performance liquid chromatography, capillary electrophoresis, immunonephelometry.
Zdroje
1. Arndt, T., Carbohydrate-deficient transferrin as a marker of chronic alcohol abuse: a critical review of preanalysis, ana-lysis, and interpretation. Clin. Chem., 2001, 47, p.13-27.
2. Martiaková, K., Galajda, P., Mokáň, M. Diagnostika chronického abúzu alkoholu - význam CDT transferínu. Súčasná klinická prax, 2007, 4, p: 14-17.
3. de Jong, G., van Dijk, J.P., van Eijk H.G. The biology of transferrin. Clin. Chim. Acta., 1990, 190, p. 1-46.
4. Jeppsson, J.O., Arndt, T., Schellenberg, F., Wielders, J.P.M., Anton, R.F., Whitfield, J.B., Helander, A. International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Standardization of Carbohydrate-deficient Transferin (IFCC-WG-CDT). Toward standardization of carbohydrate-deficient transferin (CDT) measurements: I. Analyte definition and proposal of a candidate reference method. Clin. Chem. Lab. Med., 2007, 45, p. 558–562.
5. Anton, R.F., Lieber, C., Tabakoff, B. Carbohydrate-deficient transferrin and gamma-glutamyltransferase for the detection and monitoring of alcohol use: Results from a multisite study. Alcohol Clin. Exp. Res., 2002, 26, p. 1215–1222.
6. Burke, V., Puddey, I.B., Rakic, V., Swanson, N.R., Dimmitt, S.B., Beilin, L.J., Ching, S., Beilby, J.P. Carbohydrate-deficient transferrin as a marker of change in alcohol intake in men drinking 20 to 60 g of alcohol per day. Alcohol Clin. Exp. Res., 1998, 22, p. 1973–1980.
7. Mikkelsen, I.M., Kanitz, R.D., Nilssen, O., Huseby, N.E. Carbohydrate-deficient transferrin: Marker of actual alcohol consumption or chronic alcohol misuse? Alcohol Alcohol, 1998, 33, p. 646–650.
8. Schmidt, L.G., Schmidt, K., Dufeu, P., Ohse, A., Rommelspacher, H., Muller, C. Superiority of carbohydrate-deficient transferrin to gamma-glutamyltransferase in detecting relapse in alcoholism. Am. J. Psychiatry., 1997, 154, p. 75–80.
9. Jeppsson, J.O., Kristensson, H., Fimiani, C. Carbohydrate-deficient transferrin quantified by HPLC to determine heavy consumption of alcohol. Clin. Chem., 1993, 39, p. 2115–2120.
10. Sillanaukee, P., Seppa, K., Koivula, T. CDT by anion-exchange chromatogramy followed by RIA as a marker of heavy drinking among men. Alcohol Clin. Exp. Res., 1993, 17, p. 230–233.
11. Nystrom, M., Perasalo, J., Salaspuro, M. Carbohydrate-deficient transferrin (CDT) in serum as a possible indicator of heavy drinking in young university students. Alcohol Clin. Exp. Res., 1992, 16, p. 93–97.
12. Nilssen, O., Huseby, N.E., Hoyer, G., Brenn, T., Schirmer, H., Forde, O.H. New alcohol markers—how useful are they in population studies: the Svalbard study 1988–89. Alcohol Clin. Exp. Res., 1992, 16, p. 82–86.
13. Godsell, P.A., Whitfield, J.B., Conigrave, K.M., Hanratty, S.J., Saunders, J.B. Carbohydrate deficient transferrin levels in hazardous alcohol consumption. Alcohol Alcohol, 1995, 30, p. 61–66.
14. Allen, J.P. Use of biomarkers of heavy drinking in health care practice. Mil. Med., 2003, 168, p. 364-367.
15. Anttila, P., Järvi, K., Latvala, J., Blake, J.E., Niemelä, O. A new modified gama-% CDT method improves the detection of problem drinking: studies in alcoholics with or without liver disease. Clin. Chim. Acta., 2003, 338, p. 45-51.
16. Schwan, R., Albuisson, E., Malet, L., Loiseaux, M.N., Revnaud, M. Schellenberg F, Brousse G., Llorca PM. The use of biological laboratory markers in the diagnosis of alcohol misuse: an evidence-based approach. Drug Alcohol Depend, 2004, 74, p. 273-279.
17. BIO-RAD. Návod k použití: Ready-Prep % CDT by HPLCTM. Ref. 195-6670. [online]. [cit. 2017-06-20]. Dostupný na WWW: http://www.bio-rad.com/it-it/product/ready-prep-cdt-hplc.
18. SEBIA. Návod k použití: MINICAP CDT. Ref. 2208. [online]. cit. 2017-06-20]. Dostupný na WWW: http://extranet.sebia.com/sites/site/files/pdfs/12208_cz.pdf
19. Landers, J.P. Clinical Capillary Electrophoresis. Clin. Chem., 1995, 41, p. 495–509.
20. Oda R.P. et al. Capillary electrophoresis as a clinical tool for the analysis of protein in serum and other body fluids. Electrophoresis, 1997, 18, p. 1715-1723.
21. Siemens Healthineers. Návod k použití: N Latex CDT Kit, Ref. OPCS, 2012/11.
22. Helander, A., Wielders, J.P., Te Stroet, R., Bergstrom, J.P. Comparison of HPLC and capillary electrophoresis for confirmatory testing of the alcohol misuse marker carbohydrate-deficient transferrin. Clin. Chem., 2005, 51, p.1528–1531.
23. Helander, A., Bergstrom, J., Freeze, H.H. Testing for congenital disorders of glycosylation by HPLC measurement of serum transferin glycoforms. Clin. Chem. 2004, 50, p. 954–958.
24. Carchon, H.A., Chevigne, R., Falmagne, J.B., Jaeken, J. Diagnosis of congenital disorders of glycosylation by capillary zone electrophoresis of serum transferrin. Clin. Chem. 2004, 50, p.101–111.
25. Helander, A., Eriksson, G., Stibler, H., Jeppsson, J.-O. Interference of transferrin isoform types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse. Clin. Chem. 2001, 47, p.1225-1233.
26. Bortolotti, F., Trevisan, M.T., Micciolo, R., Canal, L., Vandoros, A.,Palmbach, T.M., Tagliaro, F. Re-assessment of the cut-off levels of Carbohydrate Deficient Transferrin (CDT) for automated immunoassay and multi-capillary electrophoresis for application in a forensic context. Clin. Chim. Acta., 2013, 416, p. 1-4.
27. Schellengerf, F., Girre, C., Nalpas, B., Plat, A., Tome, A., Pages, J.C. Analytical evaluation of a new capillary electrophoresis method for carbohydrate-deficient transferrin measurement. Clin. Chim. Acta., 2007, 382, p. 48-53.
28. Fermo, I., Germagnoli, L., Soldarini, A., et.al. Capillary zone electrophoresis for determination of carbohydrate-deficient transferin in human serum. Electrophoresis 2004, 25, p. 469-475.
Štítky
Clinical biochemistry Nuclear medicine Nutritive therapistČlánok vyšiel v časopise
Clinical Biochemistry and Metabolism
2018 Číslo 1
Najčítanejšie v tomto čísle
- Determination of Carbohydrate Deficient Transferrin (CDT) by various analytical techniques
- Vitamin K and its importance in laboratory medicine
- Online solid phase extraction analytical system coupled to tandem mass spectrometry for clinical applications.
- Initial study of FGF 23 measurement by LIAISON FGF 23 method