Transcatheter aortic valve implantation – diagnostic, procedure and outcomes
Authors:
Marián Kurečko; Gabriel Valočik; Marianna Vachalcová; Mariana Dvorožňáková
Authors place of work:
Klinika kardiológie VUSCH, a. s., Košice, Slovenská republika, prednosta MUDr. Stanislav Juhás, CSc.
Published in the journal:
Vnitř Lék 2015; 61(7-8): 641-648
Category:
Reviews
Summary
Transcatheter aortic valve implantation (TAVI) is an interventional method for the treatment of severe aortic stenosis. TAVI is indicated in patients who have been identified by the heart team as surgically inoperable or operable at very high risk. The advantage is minimal invasive approach with the absence of sternotomy and extracorporeal blood circulation. Interventional procedure does not allow direct visualization of the anatomical relations at the site of the final valve position (aortic anulus). For this reason it is essential to ensure appropriate view by high quality imaging methods. A standard method for the evaluation of the anatomical relations before TAVI is multidetector computed tomography (MDCT) with 3D reconstruction. In the future, the MDCT would be replaced by three-dimensional transesophageal echocardiography (3D TEE), which does not require ionizing radiation, there is no postcontrast nephropathy and hypersensitive reaction to iodine compared to MDCT. Furthermore, it provides direct measurements during the procedure and ensures easier and cheaper dispensarisation of the patients. A multicenter randomized PARTNER trial clearly demonstrated significant benefits of inoperable patients with severe aortic stenosis treated by TAVI. Recently published CoreValve US Pivotal randomized trial demonstrated higher efficiency and safety of TAVI in direct comparison with surgical treatment. The aim of this review is to provide current knowledge of TAVI, preparation of the patients before the intervention, the process of intervention, dispensarisation, as well as affecting the quality of patients life.
Key words:
aortic anulus – aortic valve – heart team – multidetector computed tomography (MDCT) – three-dimensional transesophageal echocardiography (3D TEE) – transcatheter aortic valve implantation (TAVI)
Zdroje
1. Bach DS, Siao D, Girard SE et al. Evaluation of patients with severe symptomatic aortic stenosis who do not undergo aortic valve replacement: the role of subjectively overestimated operative risk. Circ Cardiovasc Qual Outcomes 2009; 2(6): 533–539.
2. O’Brien SM, Shahian DM, Filardo G et al. The Society of Thoracic Surgeons 2008 cardiac surgery risk models. 2. Isolated valve surgery. Ann Thorac Sur 2009; 88(Suppl 1): S23-S42.
3. Florath I, Albert A, Boening A et al. Aortic valve replacement in octogenarians: identification of high-risk patients. Eur J Cardiothorac Sur 2010; 37(6): 1304–1310.
4. Rodés-Cabau J, Webb JG, Cheung A et al. Transcatheter aortic valve implantation for the treatment of severe symptomatic aortic stenosis in patients at very high or prohibitive surgical risk: acute and late outcomes of the multicenter Canadian experience. J Am Coll Cardiol 2010; 55(11): 1080–1090.
5. Webb JG, Altwegg L, Boone RH et al. Transcatheter aortic valve implantation: impact on clinical and valve-related outcomes. Circulation 2009; 119(23): 3009–3016.
6. Svensson LG, Dewey T, Kapadia S et al. United States feasibility study of transcatheter insertion of a stented aortic valve by the left ventricular apex. Ann Thorac Sur 2008; 86(1): 46–54.
7. Bruschi G, DeMarco F, Botta L et al. Direct aortic access for transcatheter self-expanding aortic bioprosthetic valves implantation. Ann Thorac Sur 2012; 94(2): 497–503.
8. Barker CM, Reardon MJ. The CoreValve US Pivotal Trial. Semin Thoracic Surg 2014; 26(3): 179–186.
9. Thomas M, Schymik G, Walther T et al. Thirty-day results of the SAPIEN aortic Bioprosthesis European Outcome (SOURCE) Registry: a European registry of transcatheter aortic valve implantation using the Edwards SAPIEN valve. Circulation 2010; 122(1): 62–69.
10. Adams DH, Popma JJ, Reardon MJ et al. Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis. N Engl J Med 2014; 370(19): 1790–1798.
11. Grube E, Buellessfeld L, Mueller R et al. Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system. Circ Cardiovasc Interv 2008; 1(3): 167–175.
12. Leon MB, Piazza N, Nikolsky E et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J 2011; 32(2): 205–217.
13. Vahanian A, Baumgartner H, Bax J et al. ESC Guidelines on the Management of Valvular Heart Disease. Eur Heart J 2012; 33(19): 2451–2496.
14. Kapadia SR. Three-year outcomes of transcatheter aortic valve replacement (TAVR) in „inoperable“ patients with severe aortic stenosis. The PARTNER trial investigators. Transcatheter cardiovascular terapeutics conference. Miami, FL. October 24, 2012. Dostupné z WWW: <http://solaci.org/es/pdfs/tct2012/5_samir_kapadia.pdf>.
15. Leon MB, Craig R, Smith CR et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Eng J Med 2010, 363(17): 1597–1607.
16. Makkar RR, Fontana GP, Jilaihawi H. Transcatheter aortic-valve replacement for inoperable severe aortic stenosis. N Eng J Med 2012; 366(18): 1696–1704. Erratum in N Engl J Med 2012; 367(9): 881.
17. Kahlert P, Knipp SC, Schlamann M et al. Silent and apparent cerebral ischemia after percutaneous transfemoral aortic valve implantation: a diffusion-weighted magnetic resonance imaging study. Circulation 2010; 121(7): 870–878.
18. Ghanem A, Muller A, Nähle CP et al. Risk and fate of cerebral embolism after transfemoral aortic valve implantation: a prospective pilot study with diffusionweighted magnetic resonance imaging. J Am Coll Cardiol 2010; 55(14): 1427–1432.
19. Clavel MA, Webb JG, Pibarot P et al. Comparison of the hemodynamic performance of percutaneous and surgical bioprostheses for the treatment of severe aortic stenosis. J Am Coll Cardiol 2009; 53(20): 1883–1891.
20. Smith CR, Leon MB, Mack MJ et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Eng J Med; 2011; 364(23): 2187–2198.
21. Tamburino C, Capodanno D, Ramondo A et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation 2011; 123(3): 299–308.
22. Kodali SK, Williams MR, Smith CR et al. Two-year outcomes after transcatheter or surgical aortic-valve replacement. N Eng J Med 2012; 366(18): 1686–1695.
23. Williams M, Kodali SK, Hahn RT et al. Sex-related differences in outcomes following transcatheter or surgical aortic valve replacement in patients with severe aortic stenosis: Insights From The PARTNER Trial (Placement of Aortic Transcatheter Valve). J Am Coll Cardiol 2014; 63(15): 1522–1528.
24. Vinod HT. Three-year outcomes after transcatheter or surgical aortic valve replacement in high-risk patients with severe aortic stenosis. American college of cardiology scientific session. [online]. 11.3.2013 [cit. 25.11.2014]. Dostupné z: <http://clinicaltrialresults.org/Slides/ACC%202013/Thourani_PARTNER%20Cohort%20A_ACC%202013.ppt>.
25. Kapadia SR, Leon MB, Makkar RR et al. 5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial. Lancet 2015; 385(9986): 2485–2491. Dostupné z: <http://www.thelancet.com/journals/lancet/article/PIIS0140–6736(15)60290–2/fulltext>.
26. Kala P, Němec P, Malík P et al. The role of learning curve on the results of aortic valve implantation for severe aortic stenosis. Vnitř Lék 2014; 60(4): 316–321.
27. Gurvitch R, Tay EL, Wijesinghe N et al. Transcatheter Aortic Valve implantation: Lessons From the Learning Curve of the First 270 High-Risk Patients. Catheter Cardiovasc Interv 2011, 78(7): 977–984.
28. Himbert D, Pontnau F, Messika-Zeitoun D et al. Feasibility and outcomes of transcatheter aortic valve implantation in high-risk patients with stenotic bicuspid aortic valves. Am J Cardiol 2012; 110(6): 877–883.
29. Hayashida K, Bouvier E, Lefevre T et al. Transcatheter aortic valve implantation for patients with severe bicuspid aortic valve stenosis. Circ Cardiovasc Interv 2013; 6(3): 284–291.
30. Achenbach S, Delgado V, Hausleiter J et al. SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/replacement (TAVR). J Cardiovasc Comput Tomogr 2012; 6(6): 366–380.
31. Leipsic J, Gurvitch R, LaBounty TM et al. Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 2011; 4(4): 416–429.
32. Al Ali AM, Altwegg L, Horlick EM et al. Prevention and management of transcatheter balloon-expandable aortic valve malposition. Catheter Cardiovasc Interv 2008; 72(4): 573–578.
33. Tuzcu EM. Transcatheter aortic valve replacement malposition and embolization: innovation brings solutions also new challenges. Catheter Cardiovasc Interv 2008; 72(4): 579–580.
34. Sinning JM, Hammerstingl C, Vasa-Nicotera M et al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol 2012; 59(13): 1134–1141.
35. Gilard M, Eltchaninoff H, Iung B et al. Registry of transcatheter aortic-valve implantation in high-risk patients. N Eng J Med 2012; 366(18): 1705–1715.
36. Piazza N, de Jaegere P, Schultz C et al. Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circ Cardiovasc Interv 2008; 1(1): 74–81.
37. Altiok E, Koos R, Schroder J et al. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation. Heart 2011; 97(19): 1578–1584.
38. Ng AC, Delgado V, van der Kley F et al. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography. Circ Cardiovasc Imaging 2010; 3(1): 94–102.
39. Willson AB, Webb JG, LaBounty TM et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: implications for sizing of transcatheter heart valves. J Am Coll Cardiol 2012; 59(14): 1287–1294.
40. Piazza N, Lange R. Imaging of valvular heart disease: I can see clearly now. Anatomy of aortic valve. [online]. 2010. Dostupné z WWW: <http://org.crsti.dliv2010.s3.amazonaws.com/pdfs/034_Ovality_of_the_aortic_valve_annulus.pdf>.
41. Jilaihawi H, Kashif M, Fontana G et al. Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 2012; 59(14): 1275–1286.
42. Toggweiler S, Gurvitch R, Leipsic J et al. Percutaneous aortic valve replacement: vascular outcomes with a fully percutaneous procedure. J Am Coll Cardiol 2012; 59(2): 113–118.
43. Hamdan A, Guetta V, Konen E et al. Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 2012; 59(2): 119–127.
44. Masson JB, Kovac J, Schuler G et al. Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications. JACC Cardiovasc Interv 2009; 2(9): 811–820.
45. Willson AB, Webb JG, Gurvitch R et al. Structural integrity of balloon-expandable stents after transcatheter aortic valve replacement: assessment by multidetector computed tomography. JACC Cardiovasc Interv 2012; 5(5): 525–532.
46. Kasel AM, Cassese S, Bleiziffer S et al. Standardized imaging for aortis annular Sizing: Implications for transcatheter valve selection. JACC Cardiovasc Img 2013; 6(2): 249–262.
47. Gurvitch R, Wood DA, Leipsic J et al. Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation. JACC Cardiovasc Interv 2010; 3(11): 1157–1165.
48. Arnold M, Achenbach S, Pfeiffer I et al. A method to determine suitable fluoroscopic projections for transcatheter aortic valve implantation by computed tomography. J Cardiovasc Comput Tomogr 2012; 6(6): 422–428.
49. Van Mieghem NM, Schultz CJ, van der Boon RM et al. Incidence, timing, and predictors of valve dislodgement during TAVI with the medtronic corevalve system. Catheter Cardiovasc Interv 2012; 79(5): 726–732.
50. John D, Buellesfeld L, Yuecel S et al. Correlation of device landing zone calcification and acute procedural success in patients undergoing transcatheter aortic valve implantations with the self-expanding CoreValve prosthesis. JACC Cardiovasc Interv 2010; 3(2): 233–243.
51. Geisbusch S, Bleiziffer S, Mazzitelli D et al. Incidence and management of CoreValve dislocation during transcatheter aortic valve implantation. Circ Cardiovas Interv 2010; 3(6): 531–536.
52. Ussia GP, Scarabelli M, Mulé M et al. Dual antiplatelet therapy versus aspirin alone in patients undergoing transcatheter aortic valve implantation. Am J Cardiol 2011; 108(12): 1772–1776.
53. Hayashida K, Lefévre T, Chevalier B et al. Transfemoral aortic valve implantation new criteria to predict vascular complications. JACC Cardiovasc Interv 2011; 4(8): 851–858.
54. Walther T, Falk V, Kempfert J et al. Transapical minimally invasive aortic valve implantation: the initial 50 patients. Eur J Cardiothorac Sur 2008; 33(6): 983–988.
55. Pibarot P, Dumesnil JG. Improving assessment of aortic stenosis. J Am Coll Cardiol 2012; 60(3): 169–180.
56. Pontone G, Andreini D, Bartorelli AL et al. Feasibility and accuracy of a comprehensive multidetector computed tomography acquisition for patients referred for balloon-expandable transcatheter aortic valve implantation. Am Heart J 2012; 161(6): 1106–1113.
57. Schoenhagen P, Tuzcu EM, Kapadia SR et al. Threedimensional imaging of the aortic valve and aortic root with computed tomography: new standards in an era of transcatheter valve repair/implantation. Eur Heart J 2009; 30(17): 2079–2086.
Štítky
Diabetology Endocrinology Internal medicineČlánok vyšiel v časopise
Internal Medicine
2015 Číslo 7-8
Najčítanejšie v tomto čísle
- Ordinary disease – appendicitis
- Transcatheter aortic valve implantation – diagnostic, procedure and outcomes
- Hepatorenal syndrome – pathophysiology, diagnosis and treatment
-
Erectile dysfunction as the first sign of systemic vascular diseases and of organovascular arterial ischemic diseases.
Guidelines and Challenge of the Angiology section of Slovak Medical Chamber (AS SMC, 2015)