Summary

Initially Cone Beam CT was almost exclusively used to perform dental radiology. However, the first generation CBCT systems were later increasingly used to study sinuses, facial and nose fractures, temporomandibular joints etc. 3D-cephalometric head and neck studies became possible once CBCT systems were available that allowed scanning of the complete head. For this purpose a double rotation technique with stitching of the resulting two data sets was needed. CBCT systems on which the rotation could be stopped were needed to perform dynamic swallow or pharyngography studies. The advent of more powerful high-end CBCT systems led the way to temporal bone and skull base imaging. Finally, high-end “supine” CBCT systems using a “gantry” made small joint musculoskeletal paging possible. These non-dental CBCT studies gradually replaced conventional X-rays and CT/MDCT studies because Theky allowed imaging with higher resolution, lower radiation dose and less metal artifacts. In this paper the most important non-dental CBCT indications will be discussed.

KEYWORDS:
jaws, CT


Zdroje

1. Casselman J.W.,Quirynen M., Lemahieu S.F., Baert A.L., Bonte J.: Computed tomography in the determination of anatomical landmarks in the perspective of endosseous oral implant installation. J Head Neck Pathol, 1988, 7: 255-264.

2. Jacobs R.: Dental cone beam CT and its justified use in oral health care. JBR-BTR, 2011, 94: 254-265.

3. Pauwels R., Beinsberger J., Collaert B., Theodorakou C., Rogers J., Walker A., Cockmartin L., Bosmans H., Jacobs R., Bogaerts R., Horner K.: The SEDEN- TEX CT project consortium: effective dose range for dental cone beam computed tomography scanners. Eur J Radiol, 2012, 81: 267-271.

4. Loubele M., Bogaerts R., Van Dijck E., Pauwels R., Vanheusden S., Suetens P., Marchal G., Sanderink G., Jacobs R.: Comparison between effective radiation dose of CBCT and MSCT scanners for dentomaxillofa- cial applications. Eur J Radiol, 2009, 71: 461-468.

5. Ludlow J.B., Ivanovic M.: Compara- tive dosimetry of dental CBCT devices and 64-slices CT for oral and maxillo- facial radiology. Surg Oral Med Oral Pathol Oral Radiol Endod, 2008, 106: 106-114.

6. Miracle A.C., Mukherji S.K.: Conebeam CT of the head and neck, part 1: phys- ical principles. AJNR Am J Neurora- diol, 2009, 30: 1088-1095.

7. Miracle A.C., Mukherji S.K.: Conebeam CT of the head and neck, part 2: clini- cal applications. AJNR Am J Neurora- diol, 2009, 30: 1285-1292.

8. De Vos W., Casselman J., Swennen G.R.J.: Cone-Beam computerized to- mography (CBCT) imaging of the oral and maxillofacial region : A system- atic review of the literature. Int J Oral Maxillofacial Surg, 2009, 38: 609-625.

9. Olszewski R., Cosnard G., Macq B., Mahy P., Reychler H.: 3D CT-based cephalometric analysis: 3D cephalo- metric theoretical concept and soft- ware. Neuroradiol, 2006, 48: 853-862.

10. Swennen G.R., Schutyser F.: Three- dimensional cephalometry: spiral Multi-slice vs cone- beam computed tomography. Am J Orthod Dentofa- cial Orthop, 2006, 130: 410-416.

11. De Clerck H., Nguyen T., Koerich de Paula L., Cevidanes L.: Three-dimen- sional assessment of mandibular and glenoid fossa changes after bone-an- chored Class III intermaxillary trac- tion. Am J Orthod Dentofacial Orthop, 2012, 142: 25-31.

12. Albuquerque M.A., Gaia B.F., Caval- canti M.G.P.: Comparison between multislice and cone-beam computer- ized tomography in the volumetric as- sessment of cleft palate. Med Oral Pathol Oral Radiol Endod, 2011, 112: 249-257.

13. Wörtche R., Hassfeld S., Lux C.J., Müssig E., Hensley F.W., Krempien R., Hofele C.: Clinical application of cone beam digital volume tomogra- phy in children with cleft lip and pal- ate. Dentomaxillofac Radiol, 2006, 35: 88-94.

14. Zoumalan R.A., Lebowitz R.A., Wang E., Yung K., Babb J.S., Jacobs J.B.: Flat panel conebeam computed to- mography of the sinuses. Otolaryn- gology-Head and Neck Surgery, 2009, 140: 841-844.

15. Maillet M., Bowles W.R., McClanahan S.I., John M.T., Ahmad M.: Cone- beam computed tomography evalua- tion of maxillary sinusitis. J Endod, 2011, 37: 753-757.

16. Pazera P., Bornstein M.M., Pazera A., Sendi P., Katsaros C.: Incidental max- illary sinus findings in orthodontic pa- tients: a radiographic analysis using cone-beam computed tomography (CBCT). Orthod Craniofac Res, 2011, 14: 17-24.

17. Zain-Alabdeen E.H., Alsadhan R.I.: A comparative study of accuracy of de- tection of surface osseous changes in the temporomandibular joint using multidetector CT and cone beam CT. Dentomaxillofacial Radiol, 2012, 41: 185-191.

18. Barghan S., Tetradis S., Mallya S.M.: Application of cone beam computed tomography for assessment of the temporomandibular joints. Australian Dental J, 2012, 57: 109-118.

19. Librizzi Z.T., Tadinada A.S., Valiyaparambil J.V., Lurie A.G., Mallya S.M.: Cone-beam computed tomography to detect erosions of the temporomandibular joint: effect of field of view and voxel size on diag- nostic efficacy and effective dose. Am J Orthod Dentofacial Orthop, 2011, 140: e25-e30.

20. Shintaku W.H., Venturin J.S., Noujeim M.: Applications of cone- beam computed tomography in frac- tures of the maxillofacial complex. Dental Traumatology, 2009, 25: 358- 366.

21. Oluwasanmi A.F., Pinto A.L.: Manage- ment of nasal trauma – widespread misuse of radiographs. Brit J Clin Governance, 2000, 5: 83-85.

22. De Ceulaer J., Swennen G., Abeloos J, De Clercq C.: Presentation of a cone- beam CT scanning protocol for pre- prosthetic cranial bone grafting of the atrophic maxilla. Int J Oral Maxillofac Surg, 2012, 41 : 863-866.

23. Dahmani-Causse M., Marx M., Deguine O., Fraysse B., Lepage B, Escudé B.: Morphologic examination of the temporal bone by cone beam computed tomography: comparison with multislice helical computed to- mography. Eur Ann Otorhinolaryng Head and Neck diseases, 2011, 128: 230-235.

24. Ruivo J., Mermuys K., Bacher K., Kuhweide R., Offeciers E., Casselman J.W.: Cone beam computed tomogra- phy, a low-dose imaging in the post- operative assessment of cochlear im- plantation. Otol Neurotol, 2009, 30: 299-303.

25. Trieger A., Schulze A., Schneider M., Mürbe D.: In vivo measurements of the insertion depth of cochlear im- plant arrays using flat-panel volume computed tomography. Otol Neu- rotol, 2010, 32: 152-157.

26. Penninger R.T., Tavassolie T.S., Carey J.P.: Cone-beam volumetric tomography for applications in the temporal bone. Otol Neurotol, 2011, 32: 453-460.

27. De Cock J., Mermuys K., Goubau J., Van Petegem S., Houthoofd B., Casselman J.W.: Cone-Beam comput- ed tomography: a new low dose, high resolution technique of the wrist, pre- sentation of three cases with tech- nique. Skeletal Radiol, 2012, 41: 93-96.

28. Zbijewski W., De Jean P., Prakash P., Ding Y., Stayman J.W., Packard N., Senn R., Yang D., Yorkston J., Machado A., Carrino J.A., Siewerdsen J.H.: A dedicated cone-beam CT sys- tem for musculoskeletal extremities imaging: design, optimization, and initial performance characterization. Am Assoc Phys Med, 2011, 38: 4700- 4713.

29. Smith E.J., Al-Sanawi H.A., Gammon B., St. John P.J., Pichora D.R., Ellis R.E.: Volume slicing of cone-beam computed tomography images for navi- gation of percutaneous scaphoid fixa- tion. Int J CARS, 2012, 7: 433-444.

30. Wihlm R.R., Le Minor J.M., Schmittbuhl M., Jeantroux J., Mac Mahon P., Veillon F., Dosch J.C., Dietemann J.L., Bierry G.: Cone-beam computed tomography arthrography: an inno- vative modality for the evaluation of wrist ligament and cartilage injuries. Skeletal Radiol, 2012, 41: 963-969.

31. Dreiseidler T., Ritter L., Rothamel D., Neugebauer J., Scheer M., Mischkowski R.A.: Salivary calculus diagnosis with 3-dimensional cone-beam computed tomography. Oral Maxillofacial Radiol, 2010, 110: 94-100.

32. Li B., Long X., Cheng Y., Wang S.: Cone beam CT sialography of stafne bone cavity. Dentomaxillofac Radiol, 2011, 40: 519-523.

33. Yoshihara M., Terajima M., Yanagita N., Hyakutake H., Kanomi R., Kitahara T., Takahashi I.: Three-dimensional analysis oft he pharyngeal airway morphology in growing Japanese girls with and without cleft lip and palate. Am J Orthod Dentofacial Orthop, 2012, 141: S92-101.

34. El A.S., El H., Palomo J.M., Baur D.A.: A 3-dimensional airway analysis of an obstructive sleep apnea surgical correction with cone beam computed tomography. J Oral Maxillofac Surg, 2011, 69: 2424-2436.

35. Park S.B., Kim Y.I. Son W.S., Hwang D.S., Cho B.H.: Cone-beam computed tomography evaluation of short- and long-term airway change and stability after orthognatic surgery in patients with Class III skeletal deformities: bi- maxillary surgery and manbibular setback surgery. Int J Oral Maxillofac Surg, 2012, 41: 87-93.

Štítky
Audiology Paediatric ENT ENT (Otorhinolaryngology)
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#