Supracor, Laser Correction of Presbyopia: One-year Follow-up Outcomes
Authors:
H. Machačová; E. Vlková; L. Michalcová; V. Trnková; N. Rybárová
Authors place of work:
Oční klinika FN Brno a LF MU, Brno, přednostka prof. MUDr. Eva Vlková, CSc.
Published in the journal:
Čes. a slov. Oftal., 70, 2014, No. 4, p. 146-150
Category:
Původní práce
Summary
Purpose:
Evaluation of one-year postoperative results after Supracor laser procedure.
Methods:
The study group consisted of 8 hyperopic patients (16 eyes) seeking alternatives to wearing glasses for both distance and near vision. These patients underwent Supracor refractive surgery in the Department of Ophthalmology of The University Hospital Brno in the time period from July 2012 to February 2013. The patient mean age at operation was 57,2 years (±4,6), mean binocular uncorrected near visual acuity was Jaeger No. 13, distance visual acuity 0,5 (±0,19). Average follow-up period was 15,5 months (±2,4). We evaluated binocular uncorrected and best corrected distance visual acuity (UDVA, BCDVA), near visual acuity (UNVA, BCNVA), and intermediate visual acuity (UIVA, BCIVA) 12 months after surgery, further the stability of visual acuity, objective refraction, mesopic contrast sensitivity, occurrence of complications, and patient satisfaction.
Results:
In all 8 patients, binocular UDVA of at least 1,0 was achieved. The mean spherical equivalent was +0,25 D (±0,64). UNVA was Jaeger No. 3 or better in 7 patients (68,7 %), 5 of them could read Jaeger No. 1. UIVA Jaeger No. 1 was achieved in 5 patients (62,5 %), Jaeger No. 2 in 2 patients (25 %), and Jaeger No. 4 in 1 patient (12,5 %). In all eyes, preoperative mesopic contrast sensitivity was within the normal range for the given age. Postoperatively it remained within the normal range in 11 eyes (68,7 %). In 5 eyes (31,3 %) we found adecrease below the lower limit in higher spatial frequencies (12 and 18 cycles/degree) during the entire follow-up period. According to the patient questionnaire, 7 patients (87,5 %) were fully satisfied with the outcome of the surgery and they felt independent of wearing glasses, 1 patient was dissatisfied. 7 patients (87,5 %) did not report the presence of photic phenomena (halo, glare), 1 patient suffered from these problems. We did not encounter any intraoperative or postoperative complications.
Conlusion:
According to our first experience, good distance, near, and intermediate visual acuity and arather high patient satisfaction can be achieved with the use of the Supracor procedure. Supracor seems to be asuitable method of presbyopia correction in motivated, adaptable patients who meet strict indication criteria. With regard to the small number of patients in our study group, agreater number of patient evaluations will be required in the future, and long-term results will be of interest as well.
Key words:
Supracor, presbyopia, LASIK, refractive surgery
Zdroje
1. Alió, J. L., Chaubard, J. J., Caliz, A. et al.: Correction of presbyopia by technovision central multifocal LASIK (presbyLASIK). J Refract Surg, 2006; 22: 453–460.
2. Barišić, A., Barić, N., Dekaris, I. et al.: Comparison of Different Presbyopia Treatments: Refractive Lens Exchange with Multifocal Intraocular Lens Implantation Versus LASIK Monovision. Coll Antropol, 34, 2010; 2: 95–98.
3. Cosar, C. B., Sener, A. B.: Supracor hyperopia and presbyopia correction: 6-month results. Eur J Ophthalmol, 24, 2014; 3: 325–329.
4. Fintelmann, R. E., Naseri, A.: Prophylaxis of postoperative endophthalmitis following cataract surgery: current status and future directions. Drugs, 70, 2010; 11: 1395–1409.
5. Holzer, M. P., Knorz, M. C., Tomalla, M. et al.: Intrastromal femtosecond laser presbyopia correction: 1-year results of a multicenter study. J Refracr Surg, 28, 2012, 3: 182–188.
6. Holzer, M. P., Mannsfeld, A., Ehmer, A. et al.: Early outcomes of INTRACOR femtosecond laser treatment for presbyopia. J Refract Surg, 25, 2009; 10: 855–861.
7. Krader, Ch. G., Ryan, A.: LASIK treats hyperopic presbyopia, Ophthalmology Times, 37, 2012; 22: 20.
8. Novák, P.: Refrakční vady a jejich řešení. In Kuchynka, P., Oční lékařství, Praha, Grada Publishing, a.s., 2007, s. 115.
9. Machačová, H., Vlková, E., Pirnerová, L. et al.: Supracor – moderní metoda řešení presbyopie, XXI. Výroční sjezd České oftalmologické společnosti ČLS JEP, sborník abstrakt, Brno, 19. - 21. 9. 2013, Hradec Králové: HANZO Production, spol. s r.o., 2013, s 119. ISBN 970-80-905115-4-5.
10. Montés-Micó, R., Rodriguéz-Galietero, A., Alió, J. L. et al.: Contrast sensitivity after LASIK flap creation with a femtosecond laser and a mechanical microkeratome. J Refract Surg., 23, 2007; 2: 188–192.
11. Pirnerová, L., Vlková, E., Trnková, V. et al.: Supracor – výsledky ročního sledovacího období, XXI.Výroční sjezd České oftalmologické společnosti ČLS JEP, sborník abstrakt, Brno, 19. – 21. 9. 2013, Hradec Králové: HANZO Production, spol. s r.o., 2013, s 109. 2013. ISBN 970-80-905115-4-5.
12. Ryan, A., O´Keefe, M.: Corneal approach to hyperopic presbyopia treatment: Six-month outcomes of a new multifocal excimer laser in situ keratomileusis procedure. J Cataract Refract Surg, 39, 2013, 8: 1226–1233.
13. Torricelli, A. M., Junior, J. B., Santhiago, M. R. et al.: Surgical management of presbyopia. Clinical Ophthalmology, 2012, 6: 1459–1466.
14. Truscott, R. J., Zhu, W.: Presbyopia and cataract: A question of heat and time, Prog Retin Eye Res, 29, 2010, 6: 487–499.
15. Urminský, J., Rozsíval, P., Lorencová, V. et al.: Použití akomodačních čoček k chirurgické korekci presbyopie metodou Prelex. Čes a slov Oftal, 2006, 5: 324–333.
16. Warung, G. O., Berry, D. E.: Advances in the surgical correction of presbyopia. Int Ophthalmol Clin, 53, 2013, 1: 129–152.
17. Zhao, L. Q., Zhu, H.: Contrast sensitivity after zyoptix tissue saving LASIK and standard LASIK for myopia with 6-month followup. J Ophthalmol, 2011, dostupné z: http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3090770/.
Štítky
OftalmológiaČlánok vyšiel v časopise
Česká a slovenská oftalmologie
2014 Číslo 4
- Konzervační látka polyquaternium-1 zvyšuje cytotoxicitu a zánět spojený s NF-kappaB u epitelových buněk lidské rohovky
- Myasthenia gravis: kombinace chirurgie a farmakoterapie jako nejefektivnější modalita?
- Pomocné látky v roztoku latanoprostu bez konzervačních látek vyvolávají zánětlivou odpověď a cytotoxicitu u imortalizovaných lidských HCE-2 epitelových buněk rohovky
- Dlouhodobé výsledky lokální léčby cyklosporinem A u těžkého syndromu suchého oka s 10letou dobou sledování
- Syndrom suchého oka
Najčítanejšie v tomto čísle
- Lymfangiom orbitopalpebrální oblasti
- Cytomegalovirová retinitida u pacienta se syndromem získané imunodeficience
- Supracor, laserová metoda korekce presbyopie: výsledky ročního sledování
- Klinické nálezy u členů rodiny s výskytem izolované aniridie v důsledku PAX6 mutace