Shute´s parallel forceps
Authors:
A. Barták; M. Halaška
Authors place of work:
Gynekologicko-porodnická klinika 1. LF UK a Nemocnice Na Bulovce, Praha, přednosta prof. MUDr. M. Halaška, DrSc.
Published in the journal:
Ceska Gynekol 2014; 79(4): 332-336
Summary
By invention of his forceps in 1950´s W. B. Shute introduces a new principle of parallelism, which is characterised by higher safety for the foetus. The main advantage is that the force acting on the head can be exactly controlled. Authors explain design and use of the instrument which is, by it´s indications and versatility, similar to Kjelland´s forceps. Literary review is cited and brief biografy of inventor is added. Where Shute´s instrument is available, priority shoud be given to it, as parallel forceps exceeds the Kjelland´s one by it´s safety for the foetus and moreover is easier to use and to learn too.
Keywords:
parallel forceps, W. B Shute, obstetrical operations, obstetrical forceps
Zdroje
1. Doležal, A. Porodnické operace. Praha: Grada Publishing, 2007, s. 163–164. ISBN 978-80-274-0881-2.
2. Harb, M. Diskusní příspěvek v House of Commons z 15.3.2002. Dostupné z http://openparliament.ca/politicians/4675/ [vid. 30.12.2013]
3. Issel, EP. Mechanical action of obstetrical forceps on the fetal skull. Zentralbl Gynakol, 1977, 99(8), s. 487–497.
4. Nieder, L., Lattorff, E. Optimum approach to delivery for control of premature birth; Zentralbl Gynakol, 1980, 102(2), s. 84–92.
5. Papež, L., Srp, B., et al. Roční zkušenost se Shuteho kleštěmi. Čs Gynekol, 1972, 37(2), s. 89.
6. Pearse, WH., Kolbeck, TJ. Compressive forces of the Shute forceps. Am J Obstet Gynecol, 1972, 113(1), p. 44–46.
7. Public Register of Arms, Flags and Badges: Wallace Beresford Shute. Dostupné z http://reg.gg.ca/heraldry/pub-reg/project-pic.asp?lang=e&ProjectID=1414&ProjectImageID=2219 [vid. 30.12.2013]
8. Royal College of Obstetricians and Gynaecologists. SHUTE, Wallace Beresford (b1911): Shute Forceps papers. Dostupné z http://www.aim25.ac.uk/cats/7/2384.htm, [vid. 30.12.2013]
9. Seidenschnur, G., Heinrich, J., et al. Zur Frage des Schadigungsrisikos bei Entbindungen durch Shute-Forceps. Zentralbl Gynekol, 1977, 99(21), s. 1286–1293.
10. Seidenschnur, G, Koepcke, E. Fetal risk in delivery with the Shute parallel forceps: analysis of 1503 forceps deliveries. Am J Obstet Gynecol, 1979, 135(3), p. 312–137.
11. Shute, WB. An obstetrical forceps using a new principle of parallelism. Proc R Soc Med, 1958, 51 (10), p. 837–839. Dostupné také z http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1889853/, [vid. 16.11.2013]
12. Shute, WB. An obstetrical forceps which uses a new principle of parallelism. Am J Obstet Gynecol, 1959, 77(2), p. 442–446.
13. Spencer-Gregson, N. Experience in the use of the Shute´s parallel forceps. Brit J Clin Pract, 1966, 20(12), p. 629-634.
14. Stranz, G., Krzyzanowski, A. Erfanrungen mit den Parallelanzage nach Shute. Zeitschr Arztl Fortbld, 1980, 74(8), s. 360–363.
15. Thiery, M. Wallace, B. Shute en de „Shute parallel forceps“. Tijdschrift Voor Geneeskunde, 1999, 55(9), s. 683–685.
16. Vinšová, N., Bendl, J., et al. Stav dětí porozených paralelními kleštěmi Shuteho. Čs Gynekol, 1972, 37(6), s. 381–382.
17. Wilson, LH. Shute´s parallel forceps – an australian experience. Austr New Zealand J Obstet Gynaecol, 1969, 9, p. 56–58. DOI: 10.1111/j.1479-828X.1969.tb02526.x; publikováno online 13.2.2008
Štítky
Paediatric gynaecology Gynaecology and obstetrics Reproduction medicineČlánok vyšiel v časopise
Czech Gynaecology
2014 Číslo 4
Najčítanejšie v tomto čísle
- Prebioptic methods in the cervical cancer screening
- Pregnancy and delivery in patients with an implanted shunt for hydrocephalus
- Principles and limits of clinical methods in the diagnosis of fetal hypoxia
- Tuberculosis in pregnancy:a challenging differential diagnosisfor inflammatory bowel disease