Endoscopic Collection of V. Saphena Magna – Early Complication Rates


Authors: V. Kurfirst;  I. Dusil;  M. Rezler;  A. Mokráček
Authors place of work: Kardiochirurgické oddělení Nemocnice České Budějovice, a. s. prim. MUDr. Aleš Mokráček, CSc.
Published in the journal: Rozhl. Chir., 2009, roč. 88, č. 11, s. 625-628.
Category: Monothematic special - Original

Summary

Endoscopic harvesting of v. saphena magna for CABG procedures represents a modern method, which in comparison to conventional methods reduces postoperative wound complications. We have analyzed 40 patients, who uderwent CABG procedure with endoscopic harvested venous graft.

Key words:
endoscopic harvesting of v. saphena magna – wound complications – CABG - Datascope


Zdroje

1. Seabolt, P. B., Reardon, M. J. Endoscopic vein harvesting in cardiac surgery. Curr. Opin. Cardiol., 2003, Nov; 18(6): 444–446.

2. Bitondo, J. M., Daggett, W. M., Torchiana, D. F., Akins, C. W., Hilgenberg, A. D., Vlahakes, G. J., et al. Endoscopic versus open saphenous vein harvest: a comparison of postoperative wound complications. Ann. Thorac. Surg., 2002; 73: 523–528.

3. Patel, A. N., Hebeler, R. F., Hamman, B. L., Hunnicutt, C., Williams, M., Liu, L., Wood, R. E. Prospective analysis of endoscopic vein harvesting. Am. J. Surg., 2001; 182: 716–719.

4. Kiaii, B., Moon, B.C., Massel, D., Langlois, Y., Austin, T. W., Willoughby, A., et al. A prospective randomized trial of endoscopic versus conventional harvesting of the saphenous vein in coronary artery bypass surgery. J. Thorac. Cardiovasc. Surg., 2002; 123: 204–212.

5. Schurr, U. P., Lachat, M. L., Reuthebuch, O., Kadner, A., Mader, M., Seiffert, M., Hoerstrup, S. P., Zund, G., Genoni, M., Turina, M. I. Endoscopic saphenous vein harvesting for CAMG: a randomized, prospective trial. Thorac. Cardiovasc. Surg., 2002; 50: 160–163.

6. Felisky, C. D., Paull, D. L., Hill, M. E., Hall, R. A., Ditkoff, M., Campbell, W. G., Guyton, S. W. Endoscopic greater saphenous vein harvesting reduces the morbidity of coronary artery bypass surgery. Am. J. Surg., 2002; 5: 576–579.

7. Andreasen, J. J., Nekrasas, V., Dethlefsen, C. Endoscopic vs open saphenous vein harvest for coronary artery bypass grafting: a prospective randomized trial. Eur. J. Cardiothorac. Surg., 2008; 34: 384–389.

8. Vaidyanathan, K. R., Sankar, M. N., Cherian, K. M. Endoscopic vs Conventional Vein Harvesting: a Prospective Analysis. Asian Cardiovasc. Thorac. Ann., 2008; 16: 134–138.

9. Griffith, G. L., Allen, K. B., Waller, B. F., Heimansohn, D. A., Robinson, R. J., Schier, J. J., et al. Endoscopic and traditional saphenous vein harvest: a histologic comparison. Ann. Thorac. Surg., 2000; 69: 520–523.

10. Kiaii, B., Moon, B. C., Massel, D., Langlois, Y., Austin, T. W., Willoughby, A., et al. A prospective randomized trial of endoscopic versus conventional harvesting of the saphenous vein in coronary artery bypass surgery. J. Thorac. Cardiovasc. Surg., 2002; 123: 204–212.

11. Black, E. A., Guzik, T. J., West, N. E., Campbell, K., Pillai, R., Ratnatunga, C., et al. Minimally invasive saphenous vein harvesting: effects on endothelial and smooth muscle function. Ann. Thorac. Surg., 2001; 71: 1503–1507.

12. Cable, D. G., Dearani, J. A., Pfeifer, E. A., Daly, R. C., Schaff, H. V. Minimally invasive saphenous vein harvesting: endothelial integrity and early clinical results. Ann. Thorac. Surg., 1998; 66: 139–143.

13. Rinia-Feenstra, M., Stooker, W., de Graaf, R., Kloek, J. J., Pfaffendorf, M., de Mol, B. A., et al. Functional properties of the saphenous vein harvested by minimally invasive techniques. Ann. Thorac. Surg., 2000; 69: 1116–1120.

14. Allen, K. B., Heimansohn, D. A., Robinson, R. J., Schier, J. J., Griffith, G. L., Fitzgerald, E. B. Influence of Endoscopic versus Traditional Saphenectomy on Event-Free Survival: Five-Year Follow-up of a Prospective Randomized Trial. Heart Surg Forum 6: E143–145.

15. Yun, K. L., Wu, Y., Aharonian, V., Mansukhani, P., Pfeffer, T. A., Sintek, C. F., et al. Randomized trial of endoscopic versus open vein harvest for coronary artery bypass grafting: six-month patency rates. J. Thorac. Cardiovasc. Surg., 2005; 129: 496–503.

16. Davis, Z., Garber, D., Clark, S., Roth, H., Bufalino, V., Budoff, M. J., et al. Long-term patency of coronary grafts with endoscopically harvested saphenous veins determined by contrast-enhanced electron beam computed tomography. J. Thorac. Cardiovasc. Surg., 2004; 127: 823–828.

17. Lin, T. Y., Chiu, K. M., Wang, M. J., Chu, S. H. Carbon dioxide embolism during endoscopic saphenous vein harvesting in coronary artery bypass surgery. J. Thorac. Cardiovasc. Surg., 2003; 126: 2011–2015.

18. Chiu, K. M., Chen, C. L., Chu, S. H., Lin, T. Y. Endoscopic harvest of saphenous vein: a lesson learned from 1,348 cases. Surgical endoscopy, 2008; 22(1): 183–187.

19. Rousou, L. J., Taylor, K. B., Lu, X. G., Healey, N., Crittenden, M. D., Khuri, S. F., Thatte, H. S. Saphenous Vein Conduits Harvested by Endoscopic Technique Exhibit Structural and Functional Damage. Ann. Thorac. Surg., 2009; 87: 62–70.

Štítky
Surgery Orthopaedics Trauma surgery

Článok vyšiel v časopise

Perspectives in Surgery

Číslo 11

2009 Číslo 11
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#