Trochanteric fractures – implants
Authors:
J. Bartoníček
Authors place of work:
Klinika traumatologie pohybového aparátu 1. LF UK a ÚVN Praha, Oddělení ortopedie a traumatologie ÚVN Praha, přednosta: Prof. MUDr. J. Bartoníček, DrSc.
Published in the journal:
Rozhl. Chir., 2013, roč. 92, č. 10, s. 589-594.
Category:
Various Specialization
Práce je určena k postgraduálnímu vzdělávání lékařů.
Summary
The current market offers a wide range of extra- and intramedullary implants. Their selection should be based on a careful consideration of their design, biomechanical properties and last but not least the quality of the instrumentation set. Mainly this may substantially influence a smooth course of the operation.
Key words:
trochanteric fractures – implants – DHS – PFN
Zdroje
1. Danis R. Théorie et practique de lęostéosynthése. Paris, Masson 1949;241.
2. Bonnaire F, Götschin U, Kuner EH. Früh- und Spätergebnisse nach 200 DHS-Osteosynthesen zur Versorgung pertrochanterer Femurfrakturen. Unfallchirurg 1992;95:246–253.
3. Schumpelick W, Jantzen PM. Die Versorgung der Frakturen im Trochantericbereich mit einer nichtsperrenden Laschenschraube. Chirurg 1953;24:506–509.
4. Schumpelick W, Jantzen PM. A new principle in the operative treatment of trochanteric fractures of the femur. J Bone Joint Surg [Am] 1955;37–A:693–698.
5. Pugh WL. A self-adjusting nail-plate for fractures about the hip joint. J Bone Joint Surg [Am] 1955;37–A:1085–1093.
6. Charnley J, Blockley NJ, Purser DW. The treatment of displaced fractures of the neck of the femur by compression. J Bone Joint Surg [Br] 1957;39–B:45–65.
7. Müller ME, Allgöwer M, Willeneger H (Hrgs). Technik der operativen Frakturbehandlung. Berlin, Springer 1963.
8. Clawson DK. Trochanteric fractures treated by the sliding screw plate fixation method. J Trauma 1964;4:737–752.
9. Dimon JH, Hughston JC. Unstable intertrochanteric fractures of the hip. J Bone Joint Surg 1967;49–A:440–450.
10. Debrunner A, Čech O. Biomechanik der Osteosynthese pertrochanter Frakturen. Z Orthop 1969;107:516–527.
11. Sarmiento A, Williams EM. Unstable intertrochanteric fracture: Treatment with a valgus osteotomy and I-beam nail-plate: A preliminary report of one hundred cases. J Bone Joint Surg [Am] 1970;52–A:1309–1318.
12. Simon-Weidner R. Die Fixierung trochanterer Brüche mit multiplen elastischen Rundnägeln nach Simon-Weidner. H Unfallheilkunde 1969;106:60–61.
13. Ender J, Simon-Weidner R. Die Fixierung trochanterer Brüche mit runden elastischen Condylennageln. Acta Chir Austriaca 1970;1:40–42.
14. Ecker ML, Joyce JJ, Kohl J. The treatment of trochanteric hip fractures using a compression screw. J Bone Joint Surg [Am] 1975;57–A:23–27.
15. Regazzoni P, Rüedi T, Winquist R, Allgöwer M. The dynamic hip screw implant system. Berlin, Springer 1985.
16. Kyle RF, Wright TM, Burnstein AH. Biomechanical analysis of the sliding characteristics of compression hip screws. J Bone Joint Surg [Am] 1980;62–A:1308–1314.
17. Říha D, Bartoníček J. Internal fixation of pertrochanteric fractures using DHS with a two-hole side-plate. Inter Orthop (SICOT)2010;34:877–882.
18. Yian EH, Banerji I, Matthews LS. Optimal side-plate fixation for unstable intertrochanteric hip fractures. J Orthop Trauma 1997;11:254–259.
19. McLoughlin SW, Wheeler D, Rider J, Bolhofner B. Biomechanical evaluation of the dynamic hip screw with two- and four-hole side-plates. J Orthop Trauma 2000;14:318–323.
20. Kuntscher G. Die Marknagelung von Knochenbrüchen. Arch Klin Chir 1940;200:443–455.
21. Zickel RE. A new fixation device for subtrochanteric fractures of the femur. A preliminary report. Clin Orthop Rel Res1967; 54:115–123.
22. Kempf I, Grosse A, Taglang G, Favreul E. Le clou gamma dans le traitment á foyer fermé des fractures trochantériennes. Resultats et indiacations á propos dęune série de 121 cas. Rev Chir Orthop 1993;79:29–40.
23. Kempf I, Taglang G. The Gamma Nail – Historical Background. Osteo Trauma Care 2005;13:2–6.
24. Werner-Tutschku W, Lajtai G, Schiedhuber G, Lang T, Pirkl C, et al. Intra- und perioperative Komplikationen bei der Stabilisierung von per- und subtrochantären Femurfrakturen mittels PFN®. Unfallchirurg 2002;105:881–885.
25. Friedl W, Clausen J. Experimentelle Untersuchungen zur Optimierung der Belastungsstabilität von Implantaten für proximale Femurfrakturen Intra- versus extramedulläre Lage des Kraftträgers und Untersuchung zur Minimierung des Ausbruchsrisikos des Schenkelhalskraftträgers. Der Chirurg 2001;72:1344–1352.
26. Augat P, Rapp S, Claes L. A modified hip screw incorporating cement for the fixation of osteoporotic trochanteric fractures. J Orthop Trauma 2002;16:311–316.
27. Kammerlander C, Gebhard F, Meier C, Lenich A, Linhart W, et al. Standardised cement augmentation of the PFNA using a perforated blade: A new technique and preliminary clinical results. A prospective multicentre trial. Injury 2011;42:1484–1490.
28. Moroni A, Faldini C, Pegrefi F, Giannini S. HA-coated screws decrease the incidence of fixation failure in osteoporotic trochanteric fractures. Clin Orthop Rel Res 2004;425:87–92.
Štítky
Surgery Orthopaedics Trauma surgeryČlánok vyšiel v časopise
Perspectives in Surgery
2013 Číslo 10
- Metamizole at a Glance and in Practice – Effective Non-Opioid Analgesic for All Ages
- Metamizole vs. Tramadol in Postoperative Analgesia
- Spasmolytic Effect of Metamizole
Najčítanejšie v tomto čísle
- Trochanteric fractures – anatomy and classification
- Are antibiotics necessary in the treatment of uncomplicated diverticulitis?
- Nailing of pertrochanteric fractures – operative technique
- Trochanteric fractures – implants