Failed preoperative lymphoscintigraphy for sentinel lymph node biopsy in breast cancer, possible causes and implications for the surgery – the analysis of 3014 procedures
Authors:
O. Coufal 1,2
; O. Zapletal 1; P. Vrtělová 1; J. Vašina 3; Z. Řehák 2,3
Authors place of work:
Oddělení chirurgické onkologie, Masarykův onkologický ústav, primář: MUDr. V. Chrenko, CSc.
1; Klinika komplexní onkologické péče, Lékařská fakulta Masarykovy univerzity
přednosta: prof. MUDr. R. Vyzula, CSc.
2; Oddělení nukleární medicíny, Masarykův onkologický ústav, primář: MUDr. Z. Řehák, Ph. D.
3
Published in the journal:
Rozhl. Chir., 2015, roč. 94, č. 3, s. 126-130.
Category:
Original articles
Summary
Introduction:
The aim of the study was to review the cases of sentinel lymph node biopsy for breast cancer in which preoperative lymphoscintigraphy had shown no axillary hot spot; to assess the frequency of failed examinations and possible causes of the failure; to analyze subsequent surgical procedures and hence to provide a general recommendation on what to do in such a situation.
Methods:
A retrospective overview of 3014 lymphoscintigraphy examinations at the Masaryk Memorial Cancer Institute from 2001 to 2011 with a more detailed analysis of the cases with axillary hot spot visualization failure.
Results:
The axillary hot spot was not shown in 71 examinations (2.4%). The frequency of failed lymphoscintigraphy during the time period did not change substantially. The possible risk factors of failed lymphoscintigraphy include: previous surgery on the breast or the axilla, obturation of the lymphatic drainage with the cancer, and the absence of the tracer injection site massage. The most common surgical procedures to respond to a failed examination were: the application of patent blue and surgical exploration of the axilla, no axillary surgery, or axillary dissection.
Conclusion:
When repeated scanning with the gamma camera through the first several hours is performed, the frequency of failed lymphoscintigraphy procedures remains very low (2.4%). If there is no axillary hot spot shown, patent blue is to be injected and the axilla should be surgically explored. This solution will be successful in most patients. If the sentinel lymph node cannot be detected even using the combined method, the surgical procedure needs to be selected with regard to the individual clinical context.
Key words:
breast cancer – sentinel lymph node – sentinel lymph node biopsy – lymphoscintigraphy – failed detection
Zdroje
1. Veronesi U, Paganelli G, Galimberti V, et al. Sentinel-node biopsy to avoid axillary dissection in breast cancer with clinically negative lymph-nodes. Lancet 1997;349: 1864−7.
2. Gatěk J, Duben J, Dudešek B, et al. Sentinelová uzlina u karcinomu prsu. Rozhl Chir 2000;79:77−80.
3. Gatěk J, Hnátek L, Dudešek B, et al. Biopsie sentinelové uzliny u karcinomu prsu v klinické praxi. Rozhl Chir 2008;87:180−5.
4. Krag DN, Anderson SJ, Julian TB, et al. Sentinel-lymph-node resection compared with conventional axillary-lymph-node dissection in clinically node-negative patients with breast cancer: overall survival findings form the NSABP B-32 randomised phase 3 trial. Lancet Oncol 2010;11:927−33.
5. Brenot-Rossi I, Houvenaeghel G, Jacquemier J, et al. Nonvisualization of axillary sentinel node during lymphoscintigraphy: is there a pathologic significance in breast cancer? J Nucl Med 2003;44:1232−7.
6. Rousseau C, Classe JM, Campion L, et al. The impact of nonvisualization of sentinel nodes on lymphoscintigraphy in breast cancer. Ann Surg Oncol 2005;12:533−8.
7. Lo YF, Hsueh S, Ma SY, et al. Clinical relevance of nonvisualized sentinel lymph nodes in unselected breast cancer patients during lymphoscintigraphy. Chang Gung Med J 2005;28:378−86.
8. Heuts EM, van der Ent FW, van der Pol HA, et al. Additional tracer injection to improve the technical success rate of lymphoscintigraphy for sentinel node biopsy in breast cancer. Ann Surg Oncol 2009;16:1156−63.
9. Abdollahi A, Jangjoo A, Dabbagh Kakhki VR, et al. Factors affecting sentinel lymph node detection failure in breast cancer patients using intradermal injection of the tracer. Rev Esp Med Nucl 2010;29:73−7.
10. Fowler JC, Solanki CK, Ballinger JR, et al. Axillary lymph node drainage pathways from intradermal and intraparenchymal breast planes. J Surg Res 2010;161:69−75.
11. Coufal O, Fait V. Biopsie sentinelové uzliny. In: Coufal O, Fait V a kol. Chirurgická léčba karcinomu prsu. Praha, Grada Publishing, 2011:207−25.
12. Meretoja TJ, Joensuu H, Heikkilä PS, et al. Safety of sentinel node biopsy in breast cancer patients who receive a second radioisotope injection after visualization failure in lymphoscintigraphy. J Surg Oncol 2010;102:649−55.
13. Chvalný P, Donát R, Dyttert D, et al. DCIS a biopsia sentinelovej uzliny. Rozhl Chir 2011;90:352−60.
14. Mergancová J, Mergancová J, Hrnčířová I, et al. Vyšetření sentinelové uzliny u in situ karcinomu prsu. Rozhl. Chir 2011;90:393−6.
15. Chetty U, Chin PK, Soon PH, et al. Combination blue dye sentinel lymph node biopsy and axillary node sampling: the Edinburgh experience. Eur J Surg Oncol 2008;34:13−6.
16. Wouters MW1, van Geel AN, Menke-Pluijmers M, et al. Should internal mammary chain (IMC) sentinel node biopsy be performed? Outcome in 90 consecutive non-biopsied patients with a positive IMC scintigraphy. Breast 2008;17:152−8.
17. Krsička P, Coufal O, Zapletal O. Pozitivní sentinelová uzlina u karcinomu prsu – kdy a proč doplňovat axilární disekci? Rozhl Chir 2013;92:684−9.
Štítky
Surgery Orthopaedics Trauma surgeryČlánok vyšiel v časopise
Perspectives in Surgery
2015 Číslo 3
- Metamizole at a Glance and in Practice – Effective Non-Opioid Analgesic for All Ages
- Metamizole vs. Tramadol in Postoperative Analgesia
- Spasmolytic Effect of Metamizole
Najčítanejšie v tomto čísle
- Low anterior resection syndrome
- Surgical repair of recurrent pectus excavatum in adults and adolescents
- Delayed liver hematoma development following deceleration injury
- Avoidance of axillary lymph node dissection in breast cancer patients with metastatic sentinel node – a pilot study