#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

h e r m o r e g u l a t i o n a n dS o m e C i r c u l a t o r y C h a n g e s d u r i n g W h o l e - b o d y B a t h s i n M i n e r a l W a t e ri n D u d i n c e


TERMOREGULAČNÉ A NIEKTORÉ CIRKULAČNÉZMENY POČAS CELKOVÉHO KÚPEĽAV MINERÁLNEJ VODE V DUDINCIACH

Pred a počas celkového kúpeľa v minerálnej vode v Dudinciach v 5., 10., 15. a 20. minúte smemerali kožnú teplotu na hrudníku, ramene, stehne a chrbte nohy, ďalej sme merali sublingválnuteplotu, srdcovú frekvenciu, systolický a diastolický krvný tlak. Z meraní sme vypočítavali priemernúkožnú a priemernú telesnú teplotu a tiež dvojitý produkt. Merania sa konali pri teplote vody 35, 36a 37 °C.Zistili sme, že celkový minerálny kúpeľ v Dudinciach s teplotou vody 35, 36 a 37 °C štatistickyvýznamne zvyšuje kožnú teplotu, priemernú kožnú teplotu, priemernú telesnú teplotu a vediek signifikantnému poklesu systolického a diastolického krvného tlaku. Pokles sublingválnej teplotydosahuje štatistickú významnosť len pri teplote kúpeľa 35 °C. Srdcová frekvencia sa zvyšuje, aleštatistickú významnosť dosahuje len pri teplote kúpeľa 36 a 37 °C. Dvojitý produkt klesá, aleštatistickú významnosť dosahuje len pri teplote kúpeľa 35 °C.

Klíčová slova:
termoregulácia, kožná teplota, telesná teplota, sublingválna teplota,srdcová frekvencia, systolický a diastolický krvný tlak, dvojitý produkt


Authors: J. Kolesár;  T. Kaiser;  M. Matej;  A. Kocinger
Authors place of work: Slovthermae, Slovenské liečebné kúpele, š. p., liečebný ústav Diamant – Dudince, riaditeľ MUDr. Miloš Matej
Published in the journal: Rehabil. fyz. Lék., , 1999, No. 3, pp. 91-95.
Category:

Summary

The authors assessed before and during whole-body baths in mineral water in Dudince spa duringthe 5 th , 10 th , 15 th and 20 st minute the skin temperature of the chest, shoulder, thigh and dorsum ofthe foot. Furthermore they measured the sublingual temperature, heart rate, systolic and diastolicblood pressure. From the data they calculated the mean skin and body temperature and also thedouble product. The measurements were made at a water temperature of 35, 36 and 37 °C.It was revealed that a whole-body mineral water bath in Dudince with a water temperature of 35, 36and 37 °C causes a significant rise of the skin temperature, the mean skin temperature, the meanbody temperature and leads to a significant drop of the systolic and diastolic blood pressure. Thedrop of the sublingual temperature is significant only at a bath temperature of 35 °C. The heart rateincreases but the increase is significant only at bath temperatures of 36 and 37 °C. The doubleproduct declines but the decline is significant only at bath temperatures of 35 °C.

Key words:
thermoregulation, skin temperature, body temperature, sublingual temperature,heart rate, systolic and diastolic blood pressure, double product

Plné znenie tohto článku nie je v digitalizovanej podobe.
V prípade záujmu kontaktujte NTO ČLS JEP, ktoré vám môže poskytnúť sken časopisu.

Štítky
Physiotherapist, university degree Rehabilitation Sports medicine

Článok vyšiel v časopise

Rehabilitation and Physical Medicine


1999 Číslo 3
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#