#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Sedation in the intensive care unit – part II. Depth of sedation monitoring using EEG signal analysis


Authors: J. Kletečka 1,2;  P. Suk 3;  V. Šrámek 3;  J. Beneš 1,2,4
Authors place of work: Klinika anesteziologie, resuscitace a intenzivní medicíny, Lékařská fakulta v Plzni, Univerzita Karlova 1;  Klinika anesteziologie, resuscitace a intenzivní medicíny, Fakultní nemocnice Plzeň 2;  Anesteziologicko‑resuscitační klinika, Fakultní nemocnice u sv. Anny v Brně, Lékařská fakulta Masarykovy univerzity v Brně 3;  Biomedicínské centrum, Lékařská fakulta v Plzni, Univerzita Karlova 4
Published in the journal: Anest. intenziv. Med., 31, 2020, č. 3, s. 103-105
Category: Review Articles

Summary

Pharmacological sedation is one of the most common therapies in the intensive care unit (ICU). Current approach is minimalization of sedation and frequent monitoring of its level, using validated sedation scales. The depth of the anaesthesia and sedation monitoring based on the automated EEG analysis is used in anaesthesiology for more than two decades. The second part of the review is focused on the development of this technology and its possible application in the ICU.

Keywords:

analgesia – EEG – sedation – BIS


Zdroje

1. Černý V, Gabrhelík T, Herold I, Mach D, Matějovič M, Stibor B. Doporučený postup analgezie a sedace dospělých pacientů v intenzivní péči. Anest intenziv Med. 2014; 25: 392–396.

2. Devlin JW, Skrobik Y, Gélinas C, Needham DM, Slooter AJC, Pandharipande PP, et al. Clinical Practice Guidelines for the Prevention and Management of Pain, Agitation/Sedation, Delirium, Immobility, and Sleep Disruption in Adult Patients in the ICU. Crit Care Med. 2018 Sep; 46(9): e825–e873.

3. Chamoun NG. An introduction to bispectral analysis for the electroencephalogram. J Clin Monit. 1994; 10(6): 392–404.

4. NICE Diagnostics Guidance: Depth of anaesthesia monitors - Bispectral index (BIS), E‑Entropy and Narcotrend Compact M 2012. [on‑line]. [cit. 2019-06-18]. Dostupné z: http:// www.nice.org.uk/dg6

5. Pandit JJ, Andrade J, Bogod DG, Hitchman JM, Jonker WR, Lucas N, et al. 5th National Audit Project (NAP5) on accidental awareness during general anaesthesia: summary of main findings and risk factors. Anaesthesia. 2014; 69(10): 1089–1101.

6. Punjasawadwong Y, Phongchiewboon A, Bunchungmongkol N. Bispectral index for improving anaesthetic delivery and postoperative recovery. Cochrane Database Syst Rev. 2014; 2014(6): CD003843.

7. Hajat Z, Ahmad N, Andrzejowski J. The role and limitations of EEG‑based depth of anaesthesia monitoring in theatres and intensive care. Anaesthesia. 2017; 72(Suppl 1): 38–47.

8. Schuller PJ, Newell S, Strickland PA, Barry JJ. Response of bispectral index to neuromuscular block in awake volunteers. Br J Anaesth. 2015; 115(Suppl 1): i95–i103.

9. Dahaba AA. Thinking outside the box; off‑label use of the Bispectral Index within context and limitations for conditions other than depth of anesthesia. Light and shadow of the BIS. Minerva Anestesiol. 2019; 85(2): 189–193.

10. Hernández‑Gancedo C, Pestaña D, Pérez‑Chrzanowska H, Martinez‑Casanova E, Cri‑ ado A, et al. Comparing Entropy and the Bispectral index with the Ramsay score in sedated ICU patients. J Clin Monit Comput. 2007; 21(5): 295–302.

11. Haenggi M, Ypparila‑Wolters H, Bieri C, Steiner C, Takala J, Korhonen I, et al. Entropy and bispectral index for assessment of sedation, analgesia and the effects of unpleasant stimuli in critically ill patients: an observational study. Crit Care. 2008; 12(5): R119.

12. Pilge S, Kreuzer M, Karatchiviev V, Kochs EF, Malcharek M, Schneider G. Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals. Eur J Anaesthesiol. 2015; 32(5): 354–365.

13. Müller JN, Kreuzer M, García PS, Schneider G, Hautmann H. Monitoring depth of sedation: evaluating the agreement between the Bispectral Index, qCON and the Entropy Module’s State Entropy during flexible bronchoscopy. Minerva Anestesiol. 2017; 83(6): 563–573.

14. Shetty RM, Bellini A, Wijayatilake DS, Hamilton MA, Jain R, Karanth S, et al. BIS monitoring versus clinical assessment for sedation in mechanically ventilated adults in the intensive care unit and its impact on clinical outcomes and resource utilization. Cochrane Database Syst Rev. 2018; 2(2): CD011240.

15. Avidan M. Awareness with recall following general anesthesia. UpToDate, Post TW (Ed), UpToDate, Waltham, MA 2019. [on‑line]. [cit. 2019-06-18]. Dostupné z: https://www.upto-date.com/contents/awareness‑with‑recall‑following‑general‑anesthesia.