#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Evaporation of Selected Cytotoxic Drugs and Permeation of Protective Gloves – Research into the Occupational Risks of Health Care Personnel Handling Hazardous Cytotoxic Drugs (CYTO Project)


Authors: L. Doležalová 1;  P. Odráška 1,2;  L. Gorná 1;  M. Prudilová 1;  R. Vejpustková 1;  L. Bláha 1,2
Authors place of work: Ústavní lékárna, Masarykův onkologický ústav, Brno 2RECETOX, Přírodovědecká fakulta MU, Brno 1
Published in the journal: Klin Onkol 2009; 22(5): 218-222
Category: Original Articles

Summary

Backgrounds:
The CYTO project studies an important aspect of healthcare provision -long term occupational exposure, both threshold and below-threshold, to chemical agents with carcinogenic and mutagenic properties, with the major focus on antineoplastic drugs. This contribution presents experimental results from the first stages of the project’s experimental work, i.e. an evaluation of the physico-chemical characteristics of cytostatic agents (evaporation) and an investigation into protective glove permeation. Materials and Methods: In co-operation with IUTA (Institut für Energie- und Umwelttechnik e.V., Duisburg, Germany), the vapour pressure of paclitaxel, doxorubicin and dacarbazine was measured following OECD guideline No. 104: Vapour pressure curve – vapour pressure balance. Furthermore, the evaporation of cytostatic drugs was examined in actual laboratory conditions by monitoring the airborne concentration using the passive sampling technique. Besides the evaporation of selected drugs, the permeation of cisplatin, cyclophosphamide, doxorubicin, 5-fluorouracil and paclitaxel through different types of gloves (vinyl, latex, nitrile) was assessed. Results: Although our experiments showed relatively slow evaporation of the evaluated cytostatic drugs (the highest pressure in paclitaxel was 0.024 Pa), equilibrium concentrations may go up to milligrams per cubic metre. Nevertheless, analytical measurements of airborne contamination did not confirm these concentration levels. The glove permeation experiments with cytostatics showed good resistance of nitrile gloves (which were impermeable to all five drugs). Other materials should be avoided while handling cytostatic agents (e.g. maximum permeation of cyclophosphamide through latex was 19 µg/sqcm/hr). Conclusion: Although the volatility of cytostatic agents is low, it cannot be neglected considering the chronic character of exposure. However, in order to estimate actual occupational exposure, future research should focus on the development of sensitive analytical methods. Nevertheless, dermal uptake is supposed to be the major route of exposure and use of protective gloves is necessary to minimize potential risks. Our simulated time-dependent permeation experiments with cytostatic agents and different glove materials showed that good protection is provided only by nitrile gloves. The results obtained in this study will be used for the modelling of exposure doses and health risk assessment in the subsequent stages of the CYTO research project.

Key words:
cytostatics – vaporization – protective gloves – occupational safety


Zdroje

1. IARC. Some antineoplastic and immunosuppresive agents. Vol. 26. IARC. Lyon, Francie, 1981.

2. IARC. Evaluation of carcinogenic risk to humans: Pharmaceutical drugs. Vol. 50. IARC. Lyon, Francie, 1990.

3. IARC. Some antiviral and antineoplastic drugs, and other pharmaceutical agents. Vol. 76. Lyon, Francie, 1999.

4. §18 nařízení vlády č. 361/2007 Sb., kterým se stanoví podmínky ochrany zdraví při práci.

5. Sessink PJM, Bos RP. Drugs hazardous to healthcare workers. Evaluation of methods for monitoring occupational exposure to cytostatic drugs. Drug Safety 1999; 20(4): 347–359.

6. §7 zákona č. 309/2006 Sb., kterým se upravují další požadavky bezpečnosti a ochrany zdraví při práci v pracovněprávních vztazích a o zajištění bezpečnosti a ochrany zdraví při činnosti nebo poskytování služeb mimo pracovněprávní vztahy (zákon o zajištění dalších podmínek bezpečnosti a ochrany zdraví při práci).

7. Turci R, Sottani C, Ronchi A et al. Biological monitoring of hospital personnel occupationally exposed to antineoplastic agents. Toxicol Lett 2002; 134(1–3): 57–64.

8. Nygren O, Gustavsson B, Ström L et al. Exposure to anti cancer drugs during preparation and administration. Investigations of an open and a closed system. J Environ Monit 2002; 4(5): 739–742.

9. Micoli G, Turci R, Arpellini M et al. Determination of 5-fluorouracil in environmental samples by solid-phase extraction and high performance liquid chromatography with ultraviolet detection. J Chromatogr B Biomed Sci Appl 2001; 750(1): 25–32.

10. Hedmer M, Georgiadi A, Bremberg ER et al. Surface contamination of cyclophosphamide packaging and surface contamination with antineoplastic drugs in a hospital pharmacy in Sweden. Ann Occup Hyg 2005; 49(7): 629–637.

11. Nygren O, Gustavsson B, Ström L et al. Cisplatin contamination observed on the outside of drug vials. Ann Occup Hyg 2002; 46(6): 555–557.

12. Fransman W, Huizer D, Tuerk J et al. Inhalation and dermal exposure to eight antineoplastic drugs in an industrial laundry facility. Int Arch Occup Environ Health 2007; 80(5): 396–403.

13. Blaha L, Dolezalova L, Odraska P. Safe handling of cytotoxic drugs: the need for monitoring and critical risk assessment. Hospital Pharmacy Europe 2008; 40: 73–75.

14. Opiolka S, Mölter W, Goldschmidt E et al. Verdampfung von Zytostatika aus Sicherheitswerkbänken, Gefahrstoffe-Reinhal. Luft 1998; 58: 291–295.

15. Poet TS, McDougal JN. Skin absorption and human risk assessment. Chem Biol Interact 2002; 140(1): 19–34.

16. Hirst M, Mills DG, Tse S et al. Occupational exposure to cyclophosphamide. The Lancet 1984; 323(8370): 186–188.

17. Connor T, Shults M, Fraser M. Determination of the vaporization of solutions mutagenic antineoplastic agents at 23 and 37oC using a desiccator technique. Mutation Research 2000; 470: 85–92.

18. Nygren O, Gustavsson B, Eriksson R. A test method for assessment of spill and leakage from drug preparation systems. Annals of Occupational Hygiene 2005; 49(8): 711–718.

19. Organizace pro ekonomický spolupráci a rozvoj. Guidelines for the testing of chemicals. 104: Vapour pressure curve – vapour presure balance. Paris: OECD 1995.

20. Klánová J, Kohoutek J, Hamplová L et al. Passive air sampler as a tool for long term air pollution monitoring: Part 1. Performance assessment for seasonal and spatial variations. Environ Pollut 2006; 144 (2): 393–405.

21. Opiolka S, Mölter W, Kiffmeyer TK et al. Dampfdürcke von Zytostatika. Gefahrstoffe-Reinhal. Luft 1999; 59: 443–444.

22. Kiffmeyer T, Kube Ch, Opiolka S et al. Vapour pressures, evaporation behaviour and airborne concentrations of hazardous drugs: Implications for occupational safety. The Pharmaceutical Journal 2002; 268: 331–337.

23. Klánová J, Čupr P, Kohoutek J et al. Assessing the influence of meteorological parameters on the performance of polyurethane foam based passive air samplers. Environ Sci Technol 2008; 42(2): 550–555.

24. Nygren O, Lundgren C. Determination of platinum in workroom air and in blood and urine from nursing staff attending patients receiving cisplatin chemotherapy. Int A Occup Environ Health 1997; 70(3): 209–214.

25. Bos RP, Weissenberger BFJ, Anzion RBM. Alpha-fluoro beta alanine in urine of workers occupationally exposed to 5-fluorouracil in a 5-fluorouracil-producing factory. Biomarkers 1998; 3(1): 81–87.

26. Minoia C, Turci R, Sottani C et al. Application of high performance liquid chromatography tandem mass spectrometry in the environmental and biological monitoring of health care personnel occupationally exposed to cyclophosphamide and ifosfamide. Rapid Commun Mass Spect 1998; 12(20): 1485–1493.

27. Sessink PJM, Vandekerkhof MCA, Anzion RBM et al. Environmental contamination and assessment of exposure to antineoplastic agents by determination of cyclophosphamide in urine of exposed pharmacy technicians – Is skin absorption an important exposure route? Arch Environ Health 1994; 49(3): 165–169.

28. Fransman W, Vermeulen R, Kromhout H. Dermal exposure to cyclophosphamide in hospitals during preparation, nursing and cleaning activities. Int Arch Occup Environ Health 2005; 78(5): 403–412.

29. Fransman W, Huizer D, Tuerk J et al. Inhalation and dermal exposure to eight antineoplastic drugs in an industrial laundry facility. Int Arch Occup Environ Health 2007; 80(5): 396–403.

30. Gross ER, Groce DF. An evaluation of nitrile gloves as an alternative to natural rubber latex for handling chemotherapeutic agents. J Oncol Pharm Pract 1998; 4(3): 165.

31. Bussieres JF, Theoret Y, Prot-Labarthe S et al. Program to monitor surface contamination by methotrexate in a hematology-oncology satellite pharmacy. Am J Health Syst Pharm 2007; 64(5): 531–535.

32. Kiffmayer T et al. Monitoring-effect study of wipe sampling in pharmacies. International Colloquium: Antineoplastic drug monitoring 30. 4. 2008, Hennef, Germany. [http://www.pharma-monitor.de/objectfiles/3080/Kiffmeyer_Germany_Int_Colloquium_Hennef_30.04.2008.pdf]

33. Odráška P, Doležalová L, Gorná L et al. Protinádorová léčiva v pracovním prostředí člověka – průběžné výsledky projektu CYTO. 12. kongres nemocničních lékárníků 14.–16. 11. 2008, Hradec Králové.

Štítky
Paediatric clinical oncology Surgery Clinical oncology

Článok vyšiel v časopise

Clinical Oncology

Číslo 5

2009 Číslo 5
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#