#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Surgical Management of the Abdominal Aortic Aneurysm in a Patient with Left-Sided Inferior Vena Cava and A Functional Solitary Left Kidney


Authors: D. Nešpor;  J. Černý;  Z. Šilhart *;  P. Němec
Authors place of work: Centrum kardiovaskulární a transplantační chirurgie Brno, ředitel: doc. MUDr. Petr Němec, CSc. ;  Chirurgická klinika Fakultní nemocnice Brno, přednosta: prof. MUDr. Zdeněk Kala, Ph. D. *
Published in the journal: Rozhl. Chir., 2010, roč. 89, č. 10, s. 634-637.
Category: Monothematic special - Original

Summary

In a polymorbid female patient, an aneurysm of the abdominal aorta was discovered incidentally, necessitating admission to an angiosurgical department. On surgery, an additional problem was found, the left-sided inferior vena cava (a congenital anomaly of the venous system) as well as the juxtarenal aneurysm of the abdominal aorta. As the patient had a solitary functioning kidney, the resection of the aortic aneurysm was considered to be associated with unacceptable risk if performed at a standard department. Therefore, the patient was transferred to the Centre of Cardiovascular Surgery and Transplantations Brno where a resection of the aneurysm was performed. On resection, the perfusion of the solitary functioning kidney was maintained with organ preservation solution used in organ transplantations. The operation was uneventful, the postoperative course was complicated only by insignificant wound healing problems.

Key words:
aneurysm of abdominal aorta – congenital left-sided inferior vena cava – solitary functioning kidney


Zdroje

1. Firt, P., Hejnal, J., Vaněk, I. Cévní chirurgie. Avicenum, 1991, 148.

2. Zeman, M., et al. Speciální chirurgie, Galén, 2001, 380.

3. Giglia, J. S., Thompson, J. K. Repair of a thoracoabdominal aortic aneurysm in the presence of a left-sided inferior vena cava. J. Vasc. Surg., 2004, 40(1), 161–163.

4. Bass, J. E., Redwine, M. D., Kramer, L. A., Huynh, P. T., Harris, J. H. Spectrum of congenital anomalies of the inferior vena cava: cross-sectional imaging findings. RadioGraphics, 2000, 20, 639–652.

5. Yeung, K. K., Jongkind, V., Coveliers, H. M. E., Tangelder, G. J., Wisselink, W. Routine continuous perfusion of the kidneys during elective juxtarenal aortic aneurysm repair. Eur. J. Vasc. Endovasc. Surg., 2008, 35, 446–451.

6. Marrocco-Trischitta, M. M., Melissano, G., Kahlberg, A., Vezzoli, G., Calori, G., Chiesa, R. The impact of aortic clamping site on glomerular filtration after juxtarenal aneurysm repair. Ann. Vasc. Surg., 2009, 23(6), 770–777.

7. Lemaire, S. A., Jones, M. M., Conklin, L. D., Carter, S. A., Criddel, M. D. Randomized comparison of cold blood and cold crystalloid perfusion for renal protection during thoracoabdominal aortic aneurysm repair. J. Vasc. Surg., 2009, 49(1), 11–19.

8. Kudo, F. A., Nishibe, T., Miyazaki, K., Murashita, T., Yasuda, K., Ando, M., Nishibe, M. Postoperative renal function after elective abdominal aortic aneurysm repair requiring suprarenal aortic cross-clamping. Surg. Today, 2004, 34, 1010–1013.

9. Kunioshi, Y., Koja, K., Miyagi, K., Uezu, T., Yamashiro, S., Arakaki, K., Nagano, T., Mabuni, K., Senaha, S. Selective visceral perfusion during thoracoabdominal aortic aneurysm repair. Ann. Thorac. Cardiovasc. Surg., 2004, 10(6), 367–372.

10. Moon, I. S., Park, S. C., Kim, S. N., Koh, Y. B. Abdominal aortic aneurysm repair in kidney transplant recipients, Transplant. Proc., 2006, 38, 2022–2024.

11. Wahlberg, E., Dimulzio, P. J., Stoney, R. J. Aortic clamping during elective operations for infrarenal disease: the influence of clamping time on renal function. J. Vasc. Surg., 2002, 36, 13–18.

Štítky
Surgery Orthopaedics Trauma surgery

Článok vyšiel v časopise

Perspectives in Surgery

Číslo 10

2010 Číslo 10
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#