Esophageal perforation caused by dislocated cervical plate five years after cervical spine surgery – a rare complication
Authors:
Radek Pohnán 1
; P. Vaněk 2; K. Menclová 1; J. Kalvach 1; D. Netuka 2
Authors place of work:
Chirurgická klinika 2. LF UK a ÚVN, Praha
1; Neurochirurgická a neuroonkologická, klinika 1. LF UK a ÚVN, Praha
2
Published in the journal:
Cesk Slov Neurol N 2019; 82(5): 577-579
Category:
Letter to Editor
doi:
https://doi.org/10.14735/amcsnn2019577
Summary
The authors declare they have no potential conflicts of interest concerning drugs, products, or services used in the study.
The Editorial Board declares that the manuscript met the ICMJE “uniform requirements” for biomedical papers.
Zdroje
1. Sahjpaul RL. Esophageal perforation from anterior cervical screw migration. Surg Neurol 2006; 68(2): 205– 209. doi: 10.1016/ j.surneu.2006.09.032.
2. Orlando ER, Caroli E, Luigi F. Management of the cervical esophagus and hypofarinx perforations complicating anterior cervical spine surgery. Spine 2003; 28(15): E290– E295. doi: 10.1097/ 01.BRS.0000087093.89889.0A.
3. Lowery GL, McDonough RF. The significance of hardware failure in anterior cervical plate fixation. Patients with 2- to 7- year follow-up. Spine (Phila Pa 1976) 1998; 23(2): 181– 187. doi: 10.1097/ 00007632-199801150-00006.
4. Yerneni K, Burke JF, Chunduru P et al. Safety of outpatient anterior cervical discectomy and fusion: a systematic review and meta-analysis. Neurosurgery 2019. in press. doi: org/ 10.1093/ neuros/ nyy636.
5. Findlay C, Ayis S, Demetriades AK. Total disc replacement versus anterior cervical discectomy and fusion. Bone Joint J 2018; 100-B(8): 991– 1001. doi: 10.1302/ 0301-620x.100b8.bjj-2018-0120.r1.
6. Feng YT, Hwang SL, Lin CL et al. Safety and resource utilization of anterior cervical discectomy and fusion. Kaohsiung J Med Sci 2008; 28(9): 495– 499. doi: 10.1016/ j.kjms.2012.04.007.
7. Garringer SM, Sasso RC. Safety of anterior cervical discectomy and fusion performed as outpatient surgery. J Spinal Disord Tech 2010; 23(7): 439– 443. doi: 10.1097/ BSD.0b013e3181bd0419.
8. Leiva-Juarez MM, Greenberg Y, La Punzina C.Migration of spinal pedicle screw with aerodigestive perforation and subsequent device expectoration. Int J Surg Case Rep 2018; 46: 6– 8. doi: 10.1016/ j.ijscr.2018. 03.037.
9. Leitner L, Brückmann CI, Gilg MM. Passage of an anterior odontoid screw through gastrointestinal tract. Case Rep Med 2017: 2923696. doi: 10.1155/ 2017/ 2923696.
10. Hytych V, Horazdovsky P, Stehlik L et al. Our own method of fixation of biodegradable tracheal stent. Bratisl Lek Listy 2015; 116(5): 340– 342. doi: 10.4149/ BLL_ 2015_064.
11. Kapu R, Singh M, Pande A et al. Delayed anterior cervical plate dislodgement with pharyngeal wall perforation and oral extrusion of cervical plate screw after 8 years: a very rare complication. J Craniovertebr Junction Spine 2012; 3(1): 19– 22. doi: 10.4103/ 0974-8237.110121.
12. Hytych V, Horazdovsky P, Pohnan R et al. VATS lobectomy, history, indication, contraindication and general techniques. Bratisl Lek Listy 2015; 116(7): 400– 403. doi: 10.4149/ BLL_2015_076.
Štítky
Paediatric neurology Neurosurgery NeurologyČlánok vyšiel v časopise
Czech and Slovak Neurology and Neurosurgery
2019 Číslo 5
- Advances in the Treatment of Myasthenia Gravis on the Horizon
- Memantine Eases Daily Life for Patients and Caregivers
- Spasmolytic Effect of Metamizole
Najčítanejšie v tomto čísle
- Treatment of insomnia in the context of neuropathic pain
- Compressive neuropathies as an occupational disease
- Changes of paraspinal muscle morphology in patients with chronic non-specific low back pain
- Endoscopic surgery for lumbar disc herniation – the first experience