#PAGE_PARAMS# #ADS_HEAD_SCRIPTS# #MICRODATA#

Correlation analysis of physical fitness and retinal microvasculature by OCT angiography in healthy adults


Authors: Pieter Nelis aff001;  Boris Schmitz aff002;  Andreas Klose aff003;  Florian Rolfes aff002;  Maged Alnawaiseh aff001;  Michael Krüger aff003;  Nicole Eter aff001;  Stefan-Martin Brand aff002;  Florian Alten aff001
Authors place of work: Department of Ophthalmology, University of Muenster Medical Center, Muenster, Germany aff001;  Institute of Sports Medicine, Molecular Genetics of Cardiovascular Disease, University Hospital Muenster, Muenster, Germany aff002;  Department of Physical Education and Sports History, University of Muenster, Muenster, Germany aff003
Published in the journal: PLoS ONE 14(12)
Category: Research Article
doi: https://doi.org/10.1371/journal.pone.0225769

Summary

Optical coherence tomography angiography (OCT-A) represents the most recent modality in retinal imaging for non-invasive and depth-selective visualization of blood flow in retinal vessels. With regard to quantitative OCTA measurements for early detection of subclinical alterations, it is of great interest, which intra- and extra-ocular factors affect the results of OCTA measurements. Here, we performed OCTA imaging of the central retina in 65 eyes of 65 young healthy female and male participants and evaluated individual physical fitness levels by standard lactate diagnostic using an incremental maximal performance running test. The main finding was that OCTA measurements of the foveal avascular zone (FAZ) area were associated with physical fitness. Using multivariate regression analysis, we found that running speed at the individual lactate threshold, a marker strongly associated with aerobic performance capacity, significantly contributed to differences in FAZ area (β = 0.111, p = 0.032). The data indicates that smaller FAZ areas are likely observed in individuals with higher aerobic exercise capacity. Our findings are also of interest with respect to the potential use of retinal OCTA imaging to detect exercise-induced microvascular adaptations in future studies.

Keywords:

Physical activity – Eyes – Tomography – exercise – Physical fitness – Angiography – Blood flow – Running

Introduction

Within the last few years, optical coherence tomography angiography (OCTA) has contributed insight to various retinal diseases by qualitative visualization of blood flow in the back of the eye.[1] One of the major challenges ahead is the definition of reliable quantitative OCTA measurements in health and disease since information on blood flow in the retinal vasculature is of major interest for early and refined diagnosis of not only ocular but also systemic diseases.[23] In this regard, there are technical issues to address such as OCT hardware, software algorithms and thresholding. Moreover, physiological intra- and extra-ocular parameters affecting the retinal vasculature are currently under (re-) investigation using highly sensitive OCTA.

Since OCTA algorithms detect blood flow based on the OCT signal scattered or reflected by moving red blood cells, one important parameter recently reported by Yang and colleagues is the hematocrit level, which significantly affects the flow signal particularly in narrow capillary vessels localized in the macula or at the optic nerve head (ONH).[4] Intraocular pressure change is an example of an intraocular parameter that influences peripapillary flow density (FD) in OCTA.[5] Other transient systemic factors, such as changes in oxygenation may also have a significant impact on FD measurements.[6] In addition, exogenous vasoactive stimulants such as caffeine have been shown to cause a reduction in macular flow area and FD.[79] Moreover, endogenous vasoactive factors can be anticipated to influence retinal perfusion in OCTA since a decrease of peripapillary and parafoveal blood flow immediately after intense physical activity has been reported.[10]

Recently, our group contributed data on long-term changes in ocular perfusion measured by OCTA in response to a controlled physical training intervention.[11] Thus, we hypothesized that regular physical activity and physical fitness might affect OCTA measures in healthy adults.

Therefore, the aim of this study was to evaluate if and to what extent physical fitness affects OCTA measures of ONH and macular blood perfusion in healthy adults.

Methods

Demographics

Sixty-five young healthy moderately trained female and male students (all Caucasian, mean age 21.52 ± 2.20 years, 43 females) of the University’s Physical Education Department were recruited at the Institute of Sports Medicine of the University Hospital Muenster in May 2017 as reported elsewhere.[11] All participating students had self-assigned to a recurrent seminar of the department in a ‘first-come first-served’ process without further selection.

All investigations were performed in accordance with the declaration of Helsinki and after the approval of the ethical committee of the medical association Westfalen-Lippe and the Westphalian Wilhelms-University of Muenster (project-no. 2013-231-f-S, study acronym SPORTIVA). Prior to subjects’ participation in the study, written informed consent was obtained. Inclusion criteria were age > 18 years, a health certificate as mandatory to study at the University’s Physical Education Department and a valid maximal performance exercise test (see below). Participants with diagnosis of any cardiovascular disease, use of cardiovascular medication or diagnosis of arterial hypertension were not eligible to participate. Any ocular pathology in the medical history as well as any pathologic alteration in structural OCT scans led to exclusion. Since axial length affects OCTA measurements of FAZ due to magnification effects particularly in higher aberrations of axial length [12], participants with spherical equivalent values higher than +3 diopters (D) and lower than -3 D were also excluded, since axial length strongly correlates with the refractive error.[13,14]

Exercise test procedures

All participants performed a standardized incremental continuous running test (ICRT, as maximal performance test) to determine their individual fitness level. The test provides information on the individual anaerobic (lactate) threshold (IAT, given as running speed [V] at IAT) and maximal exercise capacity (given as maximal running speed, Vmax). The test was performed indoors at ambient temperature (18–22°C) on a synthetic 200 m running track in groups of 4 individuals as described elsewhere.[1517] Subjects were fitted with heart rate (HR) monitors combined with a wireless receiver module (Acentas, Muenster, Germany). The test started at 8.0 km·h-1, increasing by 2.0 km·h-1 every 3 minutes until total exhaustion of the participant. The pace was indicated by an automated acoustic device. For blood lactate concentration measurements (Biosen S-line, EKF Diagnostics, Magdeburg, Germany), blood was sampled from participants’ earlobes after each interval (3 min). Performance at individual lactate threshold (baseline lactate + 1.5 mmol·L-1) was calculated using Winlactat software version 5.0.0.54 (Mesics, Muenster, Germany).[1820] Hematocrit values (epoc handheld analyzer, Alere, Cologne, Germany) were assessed in twelve randomly selected participants.

Imaging and image analysis

Subjects had been at rest before OCTA images were taken and were instructed to refrain from physical activity on the day of imaging. Additionally, the consumption of neither caffeine nor nicotine was allowed two hours prior to OCTA. Imaging was conducted with a commercial spectral domain OCT system (AngioVue, RTVue XR Avanti SD-OCT, Optovue, Fremont, CA, USA). Images were recorded from the right eye under standardized mesopic lighting conditions by an experienced operator. As there is ongoing debate in the recent literature whether circadian / diurnal changes affect OCTA measurements [21], OCTA imaging was performed in the afternoon between 4 pm and 6 pm. Volumetric scans of 304 × 304 A-scans (70,000 A-scans per second) were recorded using a light source at 840 nm. Two consecutive B-scans covering the central 3 x 3 mm2 field and the 4.5 x 4.5 mm2 ONH field were performed to compute inter-B-scan decorrelation with the split-spectrum amplitude-decorrelation angiography algorithm. The integrated software performs an automated segmentation, and displays the en-face OCTA and the structural en-face OCT image side by side. An eye tracking tool (DualTrac Motion Correction, Optovue) was used combined with an artifact removal function. For quality control, images showing insufficient signal strength (signal strength index [SSI] < 50) or an OCTA motion artifact score of three or four were excluded.[22] Automated segmentation was performed by the device according to defined reference planes as previously described.[2324] The accuracy of segmentation was checked for all reference planes by two raters. Incorrect segmentation led to exclusion.

The foveal avascular zone (FAZ) was defined as the area inside the central border of the capillary network, which was outlined using the integrated semi-automated software tool. Slab thickness for FAZ analysis was defined as the range from the inner limiting membrane (ILM) to 9 μm above the outer plexiform layer. Macular flow density (FDM) was analyzed based on the above mentioned slab definition as well as separately in the superficial plexus (FDsM) and in the deep plexus (FDdM) of the macula.

For evaluation of the peripapillary blood flow, FD in the radial peripapillary layer of the peripapillary region (FDrPP) was determined. FD was defined as the percentage of the sample area occupied by vessel lumina following binary image reconstruction. The software AngioAnalytics (version 2017.1.0.151) measures flow area, non-flow area, and FD, reporting the relative density of flow as a percentage of the total evaluated area. FD is then calculated by first extracting a binary image of the vessels from the grey scale OCTA en-face image, and then computing the percentage of pixels of vessels in the defined sector based on the binary image.[25] Macular thickness was extracted for all participants using the proprietary software tool. Choriocapillaris (CC) blood flow was quantified using the CC decorrelation signal index approach. The setting for CC imaging is a ~ 20 μm-slab between 9 μm and 31 μm below the inner retinal pigment epithelium reference. CC data were exported and further evaluated using ImageJ (Version 1.51n, National Institutes of Health, USA). Images were converted into grey scale attributing each pixel to a value that represents the strength of the decorrelation signal. CC decorrelation signal index was defined as the average decorrelation value of all pixels in the en-face CC angiogram.[26] All data were extracted and analyzed blinded to participants’ characteristics.

Statistical methods

Statistical analyses were performed using Prism 8.1 (GraphPad Software, La Jolla, USA). Data are presented as n (%), mean ± SD or median [interquartile range] in case of non-normal distribution. Data were tested for normal distribution using Kolmogorov-Smirnov test. Correlation analysis was performed using Pearson Product-Moment Correlation. For OCTA parameters showing statistically significant correlations with physical fitness measures, multiple linear regression was performed. P-value was set to 0.05.

Results

Participants anthropometric, OCTA and exercise parameters are presented in Table 1. Six of 65 participants had to be excluded due to incomplete examination records. Participants’ submaximal and maximal performance capacity determined as running speed at the individual anaerobic (lactate) threshold (speed at IAT) and maximal running speed (Vmax, speed immediately before test termination due to fatigue) were comparable to previously reported data in similar age groups (Table 1).[17]

Tab. 1. Participants’ anthropometric, optical coherence tomography angiography (OCTA) and exercise parameters.
Participants’ anthropometric, optical coherence tomography angiography (OCTA) and exercise parameters.

Exemplary performance data including the determination of the IAT and Vmax of two female and two male participants is presented in Fig 1. The exhaustive nature of the maximal performance exercise test is documented by maximal heart rate of up to ~ 200 bpm-1 and blood lactate concentration of up to ~ 18.0 mmol·L-1 (Fig 1). Since performance at IAT is a parameter associated with aerobic performance and Vmax depends on aerobic and anaerobic capacity, both parameters showed a significant but not perfect correlation (r = 0.763; p < 0.0001).

Fig. 1. Exemplary presentation of exercise parameters.
Exemplary presentation of exercise parameters.
[A] Performance of a 20-year-old female participant. Participant’s individual anaerobic threshold (IAT) was 11.2 km·h-1 (upper level compared to sex-specific mean). [B] Performance of a 21-year-old female participant. Participant’s individual IAT was 9.7 km·h-1 (lower level compared to sex-specific mean). [C] Performance of a 21-year-old male participant. Participant’s IAT was 11.1 km·h-1 (upper level compared to sex-specific mean). [D] Performance of a 24-year-old male participant. Participant’s IAT was 9.8 km·h-1 (lower level compared to sex-specific mean). Exercise heart rate (HR, ■) and blood lactate concentration (LA, ●) are shown at the different Incremental Continuous Running Test (ICRT) stages given as km·h-1. IAT is represented as vertical blue line.

No signs of pathologic ocular alteration were observed in structural OCT scans or OCTA images of any analyzed individual and parameters obtained were comparable to published data reporting on healthy individuals of identical age.[25] SSI of all images was ≥ 50. Segmentation was correct for all reference planes in all analyzed participants with 100% agreement between both raters for all eyes analyzed.

Results of the initial correlation analysis of physical performance (IAT and Vmax) with OCTA parameters are presented in Table 2. Significant inverse correlations of the FAZ area and Vmax as well as IAT were detected (Vmax, r = -0.309, p = 0.017; IAT, r = -0.279, p = 0.033). No other OCTA parameters were significantly associated with exercise performance. Scatter plots and linear regressions showing the correlation between FAZ area and performance parameters (i.e. IAT and Vmax) are presented in Fig 2.

Fig. 2.
Scatter plots of individual anaerobic lactate threshold (IAT) [A] and maximal exercise capacity (Vmax) [B] and the foveal avascular zone (FAZ). Individual data points are shown with 95% CI and linear regression.
Tab. 2. Correlation of individual anaerobic lactate threshold (IAT) and maximal exercise capacity (Vmax) and optical coherence tomography angiography (OCTA) parameters.
Correlation of individual anaerobic lactate threshold (IAT) and maximal exercise capacity (V<sub>max</sub>) and optical coherence tomography angiography (OCTA) parameters.

A multivariate regression analysis was performed to analyze the influence of IAT, Vmax, anthropometric data, SE and macular thickness on FAZ area. In the presented model, only IAT and SE contributed significantly to the regression (Table 3) (IAT: β = 0.111, p = 0.032; SE: β = 0.127, p = < 0.0001). Notably, inclusion of further OCTA parameters into the model did not affect the association of IAT with FAZ area.

Tab. 3. Multivariate regression analysis of foveal avascular zone (FAZ) area and exercise parameters, anthropomorphic data and macular parameters.
Multivariate regression analysis of foveal avascular zone (FAZ) area and exercise parameters, anthropomorphic data and macular parameters.

Of note, analysis also revealed an association between choriocapillaris decorrelation signal index (CCDI) and age, an association which has already been reported in previous histologic studies suggesting that histologically normal maculae show a decrease in density and diameter of choriocapillaris vessels with advancing age.[27]

Discussion

The current study evaluated if OCTA measurements of ocular blood flow at the posterior pole are associated with physical performance measures in young healthy adults. We found that physical fitness defined by running speed at individual anaerobic lactate threshold (IAT) was inversely correlated with the foveal avascular zone (FAZ) area.

The more precisely and unaffected from influencing factors quantitative OCTA imaging can be performed, the more effectively and sensitively natural history studies and interventional clinical trials can detect changes in ocular perfusion that may be associated with onset or progression of disease. In this regard, the identification of intra- and extra-ocular factors, which affect blood flow properties and thus OCTA measurements is of central interest.[410] We have recently reported that OCTA measurements can be altered by a physical exercise intervention. After a controlled short term (4-weeks) high-intensity interval training period, FDsM and FDnhPP values were changed and a strong effect on the FAZ area was observed, which was reduced by ~ 14%.[11] The current study provides evidence that FAZ area in OCTA images of participants with higher physical fitness was smaller compared to those with lower fitness. Other OCTA parameters were not significantly associated with exercise performance. Of note, we initially detected correlations of FAZ with both determined exercise parameters, speed at IAT and maximal exercise performance (determined as Vmax). Both exercise parameters are strongly correlated and depend largely on cardiopulmonary fitness attained by regular physical activity and exercise training. While testing methods for maximal exercise performance may (at least in part) be actively or involuntarily influenced by the tested individual and the observer, blood lactate-based measures such as the IAT are considered as reliable and objective parameters for endurance exercise performance. They can neither be influenced by the participant nor by the trainer and are determined after completion of the test. It is important to note that our study group included females and males not matched for physical fitness. However, we did not detect an effect of sex on the FAZ area although, in the multivariate analysis, sex nearly missed statistical significance. In addition, subgroup analysis of females and males did not show significant correlations between IAT/ Vmax and FAZ. With regards to these results and the unbalanced sex-ratio in our cohort, future studies are required to determine the influence of sex and physical fitness on OCTA parameters. This is also of relevance since there is ongoing discussion in the current literature concerning potential sex effects on FAZ area.[12,28]

With respect to the interpretation of OCTA-derived inter-individual FAZ data, it is important to note that current commercial OCTA devices do not correct area measurements for changes in image size magnification. Thus, the actual size of the FAZ area imaged depends on the combined magnification of the camera and the analyzed eye. Garway-Heath et al. compared different methods to correct for the magnification of the eye and concluded that using axial length to correct for magnification error was a practicable approach.[29] Consistently, several recent OCTA studies suggested a strong impact of axial length on FAZ area measurement if scan size was not corrected for differences in ocular magnification.[12,28] Sampson and colleagues, reporting on a study population comparable to our group, suggested that axial lengths in the range of 23.29–24.33 mm would correspond to less than 5% variation in FAZ area measurements.[29] Lindeman and co-workers reported an average error in FAZ area determination of 8.29% from analysis of a study population with a mean axial length of 24.04 ± 1.25 mm (range: 21.45–27.45 mm).[12] Our study did not correct OCTA FAZ measurements for optical magnification since an automated correction method is not yet implemented in currently available devices. To overcome this limitation, only participants with a spherical equivalent ± 3 D were eligible for the present study and, since the spherical equivalent strongly correlates with axial length, spherical equivalent was included in the multivariate analysis of FAZ area. Notably, most participants in our study were emmetropic with a spherical equivalent of < 0.5 D and only five participants showed a mean refractive error of -0.8 D.

So far, a number of studies have reported normative data for FAZ area size and vascular densities based on OCTA imaging in healthy individuals of different age ranges. A subgroup analysis of macular OCTA data of subjects between 20–39 years of age reported data very similar to our findings.[25] Multivariate regression in our study showed no effect of age on FAZ area, most likely because the age range of our study was quite narrow. However, study results on the correlation of age and OCTA parameters such as FAZ have been conflicting, which might also be based on the existence of so far unconsidered parameters such as physical fitness.[12,30]

Since OCTA data with information on regular physical activity or training status of the analysed participants is missing from the literature, we can only interpret our data within the findings of our own analysis. Interestingly, both performance parameters, IAT and Vmax, correlated with FAZ area size in the univariate linear regression model. However, only IAT reached statistical significance in the multivariate regression analysis. This observation might indicate that aerobic exercise capacity or regular exercise training performed to improve aerobic performance affects FAZ measurements to a greater extend then maximal exercise performance capacity. Compared to other known effectors, the effect of individual fitness on the FAZ area in OCTA appears rather moderate, particularly in comparison to the known effect of the spherical equivalent. However, also moderate effects may have biological relevance and this finding should also be interpreted with respect to the narrow range of physical fitness in our young and healthy population. The range of physical fitness in the overall population (ranging from sedentary and older individuals to young highly-trained individuals) is considerably large and future studies are needed to investigate the effect of physical fitness and regular physical activity on OCTA measurements including the FAZ area in population-based studies. Of note, no associations were detected for the investigated FD parameters, indicating that FAZ parameters are sensitive to physical activity and training over the entire range of physical performance capacity while significant effects on FD may only be detected in response to physical training in sedentary individuals. Notably, long-term training effects seem to differ from acute physical activity effects in that FDrPP, which has been shown to decrease immediately after exercise, was not associated with physical fitness in the current analysis.[10,11]

The above described observations may be explained by different effectors including local factors causing vasodilation. For instance, retinal vasomotor function is, as part of the cerebral circulation, largely dependent on local nitric oxide (NO) production.[31,32] Asymmetric dimethylarginine (ADMA), an endogenous NO synthase inhibitor, is a known independent cardiovascular risk factor and has been shown to influence arteriolar and venule diameter.[33] A comparison of obese and moderately-trained subjects as well as athletes showed a trend to lower ADMA in individuals with higher physical fitness.[34] This observation may point towards an NO-mediated mechanism for fitness-dependent blood flow measurements in the FAZ area.

Several limitations may exist for the current study. A significant effect of haematocrit on the decorrelation signal using 45%, 40% and 32% haematocrit blood samples has been described in an ex-vivo model.[4] In our study, haematocrit values were determined in twelve randomly selected participants without significant differences in haematocrit values. However, this sample may not allow to fully exclude any effects of the haematocrit in our study. The process of thresholding in OCT technology (each pixel in the OCTA en-face image is attributed a value of 0 if the pixel value in the OCT B-scan is below the threshold level), which aims at suppressing artefacts caused by noise, may have affected the current results.[35]. Furthermore, axial length measurements were not performed. However, with regard to the spherical equivalent values in our study sample, it seems not conceivable that axial length affected our measurements beyond the range of five percent as mentioned above.[28] The current study involved a group of moderately-trained healthy young individuals in a narrow age range. Compared with the age-matched general population, our participants mean performance was slightly elevated and comprised more females than males. Therefore, no direct conclusions should be drawn for patients with ocular pathologies or subjects of other age groups or subjects with inferior physical activity levels. Blood pressure and heart rate during OCTA measurements were not registered. Besides, the appearance of OCTA image data strongly depends on details of the OCT device, scan protocols, signal processing, and algorithms used to generate OCTA information from structural OCT data.[36] Therefore, the results presented must not be directly transferred to other OCTA devices.

In conclusion, we provide evidence that OCTA measurements of FAZ are associated with physical fitness. In detail, smaller FAZ areas were observed in individuals with higher aerobic exercise capacity determined by IAT.

At this point, future OCTA studies are not required to be corrected for physical activity patterns. The detected effect was moderate and based on a young and healthy group of moderately trained individuals. Follow-up studies must confirm the presented results and aim to include larger groups with wider age ranges and greater diversity in physical fitness.

The better we understand which intra- and extra-ocular variables affect OCTA measurements, the more reliable and more exact findings will be provided, also with regard to the association of retinal perfusion and pathology and the determination of potential surrogate markers at early asymptomatic disease stages.


Zdroje

1. Spaide RF, Fujimoto JG, Waheed NK, Sadda SR, Staurenghi G. Optical coherence tomography angiography. Prog Retin Eye Res. 2018;64:1–55. doi: 10.1016/j.preteyeres.2017.11.003 29229445

2. Jia Y, Bailey ST, Hwang TS, Mcclintic SM, Gao SS, Pennesi ME, et al. Quantitative optical coherence tomography angiography of vascular abnormalities in the living human eye. Proc Natl Acad Sci. 2015;112(18):E2395–402. doi: 10.1073/pnas.1500185112 25897021

3. Nelis P, Kleffner I, Burg MC, Clemens CR, Alnawaiseh M, Motte J, et al. OCT-Angiography reveals reduced vessel density in the deep retinal plexus of CADASIL patients. Sci Rep. 2018;8(1):8148. doi: 10.1038/s41598-018-26475-5 29802397

4. Yang J, Su J, Wang J, Men S, Jia Y, Huang D, et al. Hematocrit dependence of flow signal in optical coherence tomography angiography. Biomed Opt Express. 2017;8(2):776–789. doi: 10.1364/BOE.8.000776 28270984

5. Holló G. Influence of Large Intraocular Pressure Reduction on Peripapillary OCT Vessel Density in Ocular Hypertensive and Glaucoma Eyes. J Glaucoma. 2017;26(1):e7–e10. doi: 10.1097/IJG.0000000000000527 27571444

6. Pechauer AD, Jia Y, Liu L, Gao SS, Jiang C, Huang D. Optical Coherence Tomography Angiography of Peripapillary Retinal Blood Flow Response to Hyperoxia. Invest Ophthalmol Vis Sci. 2015;56(5):3287–91. doi: 10.1167/iovs.15-16655 26024111

7. Casiglia E, Bongiovì S, Paleari CD, Petucco S, Boni M, Colangeli G, et al. Haemodynamic effects of coffee and caffeine in normal volunteers: a placebo-controlled clinical study. J Intern Med. 1991;229(6):501–4. doi: 10.1111/j.1365-2796.1991.tb00385.x 2045756

8. Okuno T. Effect of Caffeine on Microcirculation of Human Ocular Fundus. Jpn J Ophthalmol. 2001;45(6):677–8.

9. Karti O, Zengin MO, Kerci SG, Ayhan Z, Kusbeci T. Acute Effect Of Caffeine On Macular Microcirculation In Healthy Subjects. Retina. 2019;39(5):964–971. doi: 10.1097/IAE.0000000000002058 29401177

10. Alnawaiseh M, Lahme L, Treder M, Rosentreter A, Eter N. Short-Term Effects Of Exercise On Optic Nerve And Macular Perfusion Measured By Optical Coherence Tomography Angiography. Retina. 2017;37(9):1642–6. doi: 10.1097/IAE.0000000000001419 27941530

11. Schmitz B, Nelis P, Rolfes F, Alnawaiseh M, Klose A, Krüger M, et al. Effects of high-intensity interval training on optic nerve head and macular perfusion using optical coherence tomography angiography in healthy adults. Atherosclerosis. 2018;274:8–15. doi: 10.1016/j.atherosclerosis.2018.04.028 29747089

12. Linderman R, Salmon AE, Strampe M, Russillo M, Khan J, Carroll J. Assessing the Accuracy of Foveal Avascular Zone Measurements Using Optical Coherence Tomography Angiography: Segmentation and Scaling. Transl Vis Sci Technol. 2017;6(3):16. doi: 10.1167/tvst.6.3.16 28616362

13. Touzeau O, Costantini E, Gaujoux T, Borderie V, Laroche L. [Correlation between refraction and ocular biometry]. J Fr Ophtalmol. 2010;33(9):659–69. doi: 10.1016/j.jfo.2010.09.007 21067845

14. Logan NS, Davies LN, Mallen EAH, Gilmartin B. Ametropia and Ocular Biometry in a U.K. University Student Population. Optom Vis Sci. 2005;82(4):261–6. doi: 10.1097/01.opx.0000159358.71125.95 15829853

15. Schmitz B, Rolfes F, Schelleckes K, Mewes M, Thorwesten L, Krüger M, Klose A, Brand SM. Longer Work/Rest Intervals During High-Intensity Interval Training (HIIT) Lead to Elevated Levels of miR-222 and miR-29c. Front Physiol. 2018;9:395. doi: 10.3389/fphys.2018.00395 29719514

16. Léger L & Boucher R. An indirect continuous running multistage field test: the Université de Montréal track test. Can J Appl Sport Sci. 1980;5:77–84. 7389053

17. Schmitz B, Klose A, Schelleckes K, et al. Yo-Yo IR1 vs incremental continuous running test for prediction of 3000m performance. J Phys Fit Sports Med. 2017;57:1391–1398.

18. Dickhuth H-H, Yin L, Niess A, Röcker K, Mayer F, Heitkamp H-C, et al. Ventilatory, Lactate-Derived and Catecholamine Thresholds During Incremental Treadmill Running: Relationship and Reproducibility. Int J Sports Med. 1999;20(02):122–7.

19. Roecker K, Schotte O, Niess AM, Horstmann T, Dickhuth H-H. Predicting competition performance in long-distance running by means of a treadmill test. Med Sci Sports Exerc. 1998;30(10):1552–7. doi: 10.1097/00005768-199810000-00014 9789858

20. Schmitz B, Schelleckes K, Nedele J, Thorwesten L, Klose A, Lenders M, et al. Dose-Response of High-Intensity Training (HIT) on Atheroprotective miRNA-126 Levels. Front Physiol. 2017;8.349. doi: 10.3389/fphys.2017.00349 28611681

21. Baek SU, Kim YK, Ha A et al. Diurnal change of retinal vessel density and mean ocular perfusion pressure in patients with open-angle glaucoma. PLoS One. 2019;14(4):e0215684. doi: 10.1371/journal.pone.0215684 31026291

22. Lauermann JL, Treder M, Heiduschka P, Clemens CR, Eter N, Alten F. Impact of eye-tracking technology on OCT-angiography imaging quality in age-related macular degeneration. Graefes Arch Clin Exp Ophthalmol. 2017;255(8):1535–42. doi: 10.1007/s00417-017-3684-z 28474129

23. Lumbroso B, Rispoli M, Savastano M. Chapter-05 Clinical Applications of OCT SSADA Angiography in Everyday Clinical Practice. Clinical OCT Angiography Atlas. 2015;20–31.

24. Enders C, Lang GE, Dreyhaupt J, Loidl M, Lang GK, Werner JU. Quantity and quality of image artifacts in optical coherence tomography angiography. Plos One. 2019;14(1):e0210505. doi: 10.1371/journal.pone.0210505 30682050

25. Coscas F, Sellam A, Glacet-Bernard A, Jung C, Goudot M, Miere A, et al. Normative Data for Vascular Density in Superficial and Deep Capillary Plexuses of Healthy Adults Assessed by Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2016;57(9):OCT211–23 doi: 10.1167/iovs.15-18793 27409475

26. Alten F, Heiduschka P, Clemens CR, Eter N. Exploring choriocapillaris under reticular pseudodrusen using OCT-Angiography. Graefes Arch Clin Exp Ophthalmol. 2016;254(11):2165–73. doi: 10.1007/s00417-016-3375-1 27193430

27. Ramrattan RS, van der Schaft TL, Mooy CM, et al. Morphometric analysis of Bruch's membrane, the choriocapillaris, and the choroid in aging. Invest Ophthalmol Vis Sci 1994;35:2857–2864. 8188481

28. Sampson DM, Gong P, An D, Menghini M, Hansen A, Mackey DA, et al. Axial Length Variation Impacts on Superficial Retinal Vessel Density and Foveal Avascular Zone Area Measurements Using Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2017;58(7):3065–3072. doi: 10.1167/iovs.17-21551 28622398

29. Garway-Heath DF, Rudnicka AR, Lowe T, Foster PJ, Fitzke FW, Hitchings RA. Measurement of optic disc size: equivalence of methods to correct for ocular magnification. Br J Ophthalmol. 1998;82(6):643–9. doi: 10.1136/bjo.82.6.643 9797665

30. Iafe NA, Phasukkijwatana N, Chen X, Sarraf D. Retinal Capillary Density and Foveal Avascular Zone Area Are Age-Dependent: Quantitative Analysis Using Optical Coherence Tomography Angiography. Invest Ophthalmol Vis Sci. 2016;57(13):5780–5787. doi: 10.1167/iovs.16-20045 27792812

31. Dorner GT, Garhofer G, Kiss B, Polska E, Polak K, Riva CE, et al. Nitric oxide regulates retinal vascular tone in humans. Am J Physiol Heart Circ Physiol. 2003;285(2):H631–6. doi: 10.1152/ajpheart.00111.2003 12750062

32. Haefliger IO, Meyer P, Flammer J, Lüscher TF. The vascular endothelium as a regulator of the ocular circulation: A new concept in ophthalmology? Surv Ophthalmol. 1994;39(2):123–32. doi: 10.1016/0039-6257(94)90157-0 7801220

33. Hemminki V, Laakso J, Kähönen M, Turjanmaa V, Uusitalo H, Lehtimäki T, et al. Plasma asymmetric dimethylarginine and retinal vessel diameters in middle-aged men. Metabolism. 2007;56(10):1305–10. doi: 10.1016/j.metabol.2007.05.012 17884437

34. Hanssen H, Nickel T, Drexel V, Hertel G, Emslander I, Sisic Z, et al. Exercise-induced alterations of retinal vessel diameters and cardiovascular risk reduction in obesity. Atherosclerosis. 2011;216(2):433–9. doi: 10.1016/j.atherosclerosis.2011.02.009 21392768

35. Cole ED, Moult EM, Dang S, Choi W, Ploner SB, Lee B, et al. The Definition, Rationale, and Effects of Thresholding in OCT Angiography. Ophthalmology Retina. 2017;1(5):435–47. doi: 10.1016/j.oret.2017.01.019 29034359

36. Trachsler S, Baston AE, Menke M. Intra- and Interdevice Deviation of Optical Coherence Tomography Angiography. Klin Monbl Augenheilkd. 2019 Mar 27. doi: 10.1055/a-0747-5333 [Epub ahead of print] 30919402


Článok vyšiel v časopise

PLOS One


2019 Číslo 12
Najčítanejšie tento týždeň
Najčítanejšie v tomto čísle
Kurzy

Zvýšte si kvalifikáciu online z pohodlia domova

Aktuální možnosti diagnostiky a léčby litiáz
nový kurz
Autori: MUDr. Tomáš Ürge, PhD.

Všetky kurzy
Prihlásenie
Zabudnuté heslo

Zadajte e-mailovú adresu, s ktorou ste vytvárali účet. Budú Vám na ňu zasielané informácie k nastaveniu nového hesla.

Prihlásenie

Nemáte účet?  Registrujte sa

#ADS_BOTTOM_SCRIPTS#