Ex vivo perfusion-based engraftment of genetically engineered cell sensors into transplantable organs
Authors:
Ling-Yee Chin aff001; Cailah Carroll aff001; Siavash Raigani aff001; Danielle M. Detelich aff001; Shannon N. Tessier aff001; Gregory R. Wojtkiewicz aff004; Stephen P. Schmidt aff004; Ralph Weissleder aff004; Heidi Yeh aff001; Korkut Uygun aff001; Biju Parekkadan aff001
Authors place of work:
Center for Surgery, Innovation, and Bioengineering, Department of Surgery, Massachusetts General Hospital, Boston, Massachusetts, United States of America
aff001; Shriners Hospitals for Children, Boston, Massachusetts, United States of America
aff002; Center for Transplant Sciences, Massachusetts General Hospital, Boston, Massachusetts, United States of America
aff003; Center for Systems Biology, Massachusetts General Hospital, Boston, Massachusetts, United States of America
aff004; Harvard Stem Cell Institute, Cambridge, Massachusetts, United States of America
aff005; Department of Biomedical Engineering, Rutgers University, Piscataway, New Jersey, United States of America
aff006
Published in the journal:
PLoS ONE 14(12)
Category:
Research Article
doi:
https://doi.org/10.1371/journal.pone.0225222
Summary
Cellular rejection of liver transplant allografts remains a concern despite immunosuppressant use. Existing transplant biomarkers are often not sensitive enough to detect acute or chronic rejection at an early enough stage to allow successful clinical intervention. We herein developed a cell-based sensor that can potentially be used for monitoring local events following liver transplantation. Utilizing a machine perfusion system as a platform to engraft the cells into a donor liver, we effectively established the biocompatibility of the biosensor cells and confirmed efficient delivery of cells distributed throughout the organ. This work proves an innovative concept of integrating synthetic reporter cells ex vivo into organs as a transplant-within-a-transplant during functional organ preservation with a vision to use cell biosensors as a broad way to monitor and treat tissue transplants.
Keywords:
Genetic engineering – Fibroblasts – Organ transplantation – Secretion – Transplantation immunology – liver transplantation – liver – Biosensors
Introduction
Liver transplantation remains the definitive surgical cure for end-stage liver disease. The last several decades have seen significant advances in the safety of transplant surgery and outcomes of recipients. Advances in immunosuppression, including the introduction of calcineurin inhibitors and mammalian target of rapamycin (mTOR) inhibitors, have improved rejection rates [1]. Detection of graft rejection, however, has lagged behind these developments. Diagnosis of post-transplant liver dysfunction, including ischemia-reperfusion injury, acute and chronic rejection, and even steatohepatitis, often requires core liver biopsies (percutaneous or endovascular), often in serial fashion. which is not without risk especially in patients with liver failure. Current serum biomarkers of graft dysfunction are also largely limited to nonspecific liver function tests. Therefore, there remains a barrier to the management of liver transplant patients at the point-of-care. Furthermore, the need for continued monitoring after diagnosis of graft dysfunction is critical given the scarcity of an organ transplants and the costs of organ failure.
Cell therapy to modulate organ dysfunction after transplantation is being increasingly explored for treatment of ischemic-reperfusion injury, prevention of chronic allograft dysfunction, minimization of immune suppression, and induction of long-term allograft tolerance. Many cell types have been investigated as potential cell-based immunotherapies for use in solid-organ transplant, including mesenchymal stromal cells, regulatory macrophages, tolerogenic dendritic cells, regulatory T cells, and regulatory B cells [2–11]. Moreover, the use of concomitant kidney and bone marrow transplants to induce mixed chimerism and tolerance [12, 13] has been explored with initial success. These cell therapies are often administered intravenously with limited half-life in the body [14, 15] and non-specific targeting to an organ bed where modulation or tolerance is needed. Thus, a significant barrier to the use of cell therapeutics to modulate organ recovery after transplant may be an inefficient delivery to sites of pathology.
To overcome the limited half-life in vivo and non-specific delivery of cell therapies for transplant modulation applications, we engineered cells to be directly engrafted into an organ prior to transplantation with machine perfusion. A rat fibroblast line was initially chosen for this study. The rationale for selection included the availability and ease of transduction, ability to engraft, and potential use in eventually modulating tissue dysfunction [16]. We did not use mesenchymal stem cells, despite the potential for eventual clinical use, to avoid potential therapeutic effects they may have which would be confounding factors in assessment of the liver function/viability. The scope of this initial work was therefore to establish the integrity of biosensor cells infused into an organ using a constitutive CMV promoter to drive the secretion of Gaussia luciferase (gLuc), a bioluminescent biomarker probe [17]. We have previously investigated the pharmacokinetics of a cell therapy coupled with gLuc monitoring of cellular transplant [18] and used this technique to confirm immune clearance of such biomarker-secreting cells [19]. Furthermore, we tested the ability of a previously established ex vivo liver perfusion system [20] as a novel and enabling platform for engrafting cell biosensors into the organs prior to transplant. Herein, we describe the process development to verify the successful engraftment of biosensor cells in donor livers, with a robust blood-based biomarker signal and minimal impact on the organ.
Methods
Rat fibroblast culture and expansion
Frozen vials of Rat2 fibroblast cell line were purchased from American Type Culture Collection (Manassas, VA, USA). Cells were thawed and cultured in Dulbecco Modified Eagle Medium (DMEM) composed of 10% fetal bovine serum (FBS) and 2% penicillin and streptomycin. Media was changed every 3–4 days and incubated at 37°C, 5% carbon dioxide. Cells were subcultured when they reached 80–90% confluence.
Genetic engineering of rat fibroblasts
Rat fibroblasts were harvested at passage 2 for lentiviral infection. A lentivirus vector expressing gLuc [17, 21] and green fluorescent protein (GFP) under the control of the CMV promoter was obtained from the Massachusetts General Hospital Vector Core (funded by NIH/NINDS P30NS045776). Cells were cultured for 24h in DMEM with increasing concentrations of lentiviral particles per cell and protamine sulfate, a cationic vehicle [22]. Transduced GFP-positive cells were sorted using a BD FACS Aria III (BD Biosciences) cell sorter (Harvard Stem Cell Institute Flow Cytometry Core at Massachusetts General Hospital, Boston, MA, USA). GFP-positive cells were then cultured, expanded and used for subsequent studies. Only passages 3–5 rat fibroblasts were used for experiments.
Animals
Male Lewis rats weighing 200g-250g were housed in standard conditions (Charles River Laboratories, Boston, MA, USA). The animals were kept in accordance with the National Research Council guidelines. The experimental protocol was approved by the Institutional Animal Care and Use Committee, Massachusetts General Hospital.
Liver procurement
All procurements were performed using the technique of Delriviere et al [23]. Animals were anesthetized using inhalation of 3–5% isoflurane (Forane, Deerfield, IL, USA) with 1 L/min 95%/5% oxygen-carbon dioxide gas. The animal’s abdomen was shaved and a transverse laparotomy was made. Intestines were moved to expose the entirety of the liver, portal vein, common bile duct, and inferior vena cava. The common bile duct was cannulated using a ~6cm 28-gauge polyethylene tube (Surflo, Terumo, Somerset, NJ, USA) to collect bile throughout the perfusion. Via the infrahepatic vena cava (IHVC), 300U of heparin was administered and 3 minutes were allowed for circulation. The portal vein was cannulated using a 16-gauge catheter and IHVC was transected for exsanguination. All cannulas were secured with 7–0 silk suture. The liver was immediately flushed in situ via the portal vein cannula with 50mL of 0.9% NaCl at 4°C. The liver was freed from its ligamentous attachments, weighed, and placed in ice-cold saline prior to being connected to the perfusion circuit.
Perfusate composition
Perfusate composition consisted of a base of DMEM supplemented with 200mM L-glutamine (Invitrogen), 10% v/v FBS (Thermo Scientific), 5% with bovine serum albumin (BSA; Sigma-Aldrich), 8mg/L dexamethasone (Sigma-Aldrich), 2000 U/L heparin (APP Pharmaceuticals), and 2 U/L insulin (Humulin, Eli Lily).
A determined concentration of 5 x 106 engineered rat fibroblasts was added to 150mL of perfusate to circulate through the system for the initial three hours. At hour three, the perfusate was switched to media without any rat fibroblasts and perfused for an additional three hours.
Normothermic machine perfusion
Normothermic machine perfusion (NMP) was chosen to maintain the liver at a metabolically active state, similar to in vivo conditions [24, 25]. The NMP circuit used was comprised of an organ reservoir, bubble trap, membrane oxygenator, roller pump, water bath, and series of silicon tubing. Prior to liver procurement, the perfusion system was first flushed with ultrapure water and warmed to 37C before perfusate was circulated.
Immediately after procurement, the liver was transferred to the organ reservoir and perfused through the portal vein cannula. The liver was perfused with partial oxygen pressure (pO2) above 400mmHg. The flow rate of the system was manually altered according to target a portal pressure of 5 mmHg, measured using a water column manometer. Flow rates initiated at 5mL/min and were increased to maintain an absolute pressure of 5 mmHg inside the liver.
Perfusate analysis
Samples of perfusate were taken at time points 0, 30, 60, 120, 180, 210, 240, 300, and 360 minutes and stored at -80ºC. Serum chemistry and blood gas analyses were performed during perfusion using CG4+ and CHEM8+ i-STAT cartridges (Abbott Point of Care Inc., Princeton, NJ, USA). Liver biopsies were taken post-perfusion and either snap-frozen in liquid nitrogen or fixed in 10% formalin. Assays for aspartate aminotransferase (AST; TR70121, Thermo Scientific) were performed following perfusion according to the manufacturer’s instructions.
Bioluminescence assays
Bioluminescence assays were performed by pipetting 10 μL of sample into a black-walled 96-well plate (Corning) and adding 1000 μL of coelenterazine native substrate (NanoLight Technology) at 100 μmol/L diluted in phosphate buffered saline. Samples were read immediately using a BioTek Synergy 2 Multi- Mode Reader for 10s at a gain of 100–200 (BioTek).
Ex vivo liver imaging
Prior to perfusion, 5×106 Rat2 fibroblasts were labeled with a near infrared fluorescent membrane dye (Qtracker 705 Cell Labeling Kit, Invitrogen). Ex vivo fluorescence imaging with the 665 excitation and 680 emission filter set was performed using the Olympus OV110 (Olympus Corporation) to visualize engraftment in liver. Image visualizations were performed in ImageJ software.
Cell lysis of gLuc-secreting cells in liver tissue
Tissue biopsied post perfusion and stored in -80°C was lysed for Gaussia Luciferase activity using NanoFuel FLASH Assay for Gaussia Luciferase (NanoLight Technology, 319). Approximately 100mg rat liver tissue was homogenized in 200uL lysis buffer, the samples were vortexed and kept on ice. After 15 minutes, 200uL of Gaussia dilution buffer was added to the samples and they were vortexed once more. Gaussia-expressing cells were used as a positive control and were prepared in the same sequence. Tissue perfused with non-transduced cells was used as a negative control. The sample volume for each well was 20uL with N = 4. Finally, 50uL of Coelenterazine buffer was injected into each well and read for Luminescence with an integration time of 10 seconds.
Histological evaluation
Once perfusion was completed tissue samples were taken from three different lobe locations. The collected samples were formalin-fixed to be paraffin-embedded. The tissue was cut into 4-micrometer sections, mounted on a glass slide, and stained for hematoxylin-eosin and/or anti-GFP antibody (Abcam ab1218).
Results
Optimization and characterization of engineered biosensor cells
We utilized self-inactivating lentiviral vectors as previously described [26] to integrate transgenes into the genome of dividing as well as non-dividing cells and pass them onto daughter cells; hence, cells will be stably expressing all genetic reporters. The lentivirus was engineered to contain a GFP gene for purifying engineered cells by FACS. In addition, a secreted gLuc reporter gene was inserted. gLuc enzyme activity can be specifically and easily quantified in a small aliquot of volume (5 μl) ex vivo by adding its respective substrate and measuring enzymatic conversion. gLuc has been used for high sensitivity detection [17, 21] with a half-life of 5–10 minutes in mouse circulation and from as few ~1000 cells in an entire mouse [26, 27]. Since these probes are secreted, accumulate in the blood, and are specific to their corresponding substrates, the signal intensity is very specific and amplified such that even a few dispersed cells can be detected using a simple bioluminescent blood test. This reporter system could enable the indirect observation, in real-time, of cell fate within an organ transplant in vivo by measuring biomarker levels in circulating fluids.
Conditions with high concentrations of lentiviral particle MOI and the cationic vehicle had the highest transduction efficiency (Fig 1A). Once rat fibroblasts were transduced with lentiviral particles, gLuc secretion was characterized during a 6-hour in vitro experiment modeled on the planned perfusion with a washout period (Fig 1B). As expected, gLuc secretion rose after cell seeding, was reduced after media exchange, and rose again with a similar rate in fresh media. When transitioning from an in vitro to an ex vivo organ perfusion model, the typical organ perfusate solution would be the vehicle that engineered cells would be circulating in. We explored gLuc release in vitro between typical fibroblast growth media (DMEM), perfusate using a DMEM base, and perfusate using a Williams E base (as previously utilized for liver perfusion). Perfusate utilizing a DMEM base resulted in higher gLuc secretion (Fig 1B) and was used for subsequent perfusions. The production of gLuc was stable, independent of cell density, and was more sensitive to the concentration of cells per cm2 (Fig 1C) when plotted on a log scale.
Biosensor cells successfully engraft in ex vivo rat livers by machine perfusion
A six-hour perfusion was previously established as a benchmark for rat liver normothermic perfusion (NMP) to preserve liver metabolic function before successful transplant into recipient rats [24]. Given the eventual aim of these biosensor cells to monitor and regulate transplanted livers, we chose to use the same six-hour perfusion in our experiments. In order to confirm successful engraftment of the biosensor cells into the liver, we infused the cells for the first three hours of the perfusion, then used fresh perfusate to check if the cells washed out. An initial cell mass of 5 x 106 engineered rat fibroblasts was chosen at a concentration of approximately 30 x 103 cells/mL to have a dilute cell suspension well below physiological circulating cell numbers.
To confirm the location of the biosensor cells within the liver, they were treated with a near-infrared (NIR) dye prior to perfusion. Cells injected directly through the cannulated liver did not distribute as thoroughly as perfused cells (S1 Fig), justifying the need for a continuous flow-based seeding process for improved biodistribution of engineered cells within the tissue. As the length of perfusion increased from 2 hours (Fig 2A) to 4 hours (Fig 2B) to 6 hours (Fig 2C), we found that longer perfusions corresponded with qualitatively improved distribution of the cells across the organ bed even after a washout period and addition of fresh perfusate. The 6-hour perfusion time qualitatively enabled distribution of cells into the periphery, which was not clearly populated in livers perfused for 2–4 hours.
Histological confirmation of biosensor cell engraftment
NIR tracking of engineered cells helped initially verify cell engraftment, though could not resolve microscopic resolution of cell localization within the tissue. Histological analysis was further performed to assess the presence of the biosensor cells embedded in the tissue by staining GFP+ cells using for anti-GFP antibody 9F9.F9 (Fig 3A and 3B). Engineered cells contained both GFP and gLuc genes and therefore the location of the cells can be tracked via GFP presence as well. The brown staining in tissue samples indicated GFP+ cells present in the tissue. Cell localization was generally near sinusoidal endothelium near portal veins. Hematoxylin-eosin (H&E) staining was used initially to histologically assess preservation injury and endothelial cell damage in liver tissue. Confluence of cells and absence of neutrophils is an indication of little to no damage caused due to the perfusion and/or addition of cells [28]. Biopsies (Fig 3C and 3D) from different liver perfusions were shown to have no major pathological damage based on these criteria.
Engrafted biosensor cells have minimal impact on liver viability functionality
Liver functionality after cell engraftment was further assessed at the organ level by comparing the biochemistries of an experimental group perfused with transduced cells, a group containing un-transduced cells, and a negative control group perfused with no cells. These groups could isolate the effect of cells alone compared to the transgene to identify a root cause of any observed effects.
To assess viability of the perfused grafts, we used the composite viability criterion of Mergental et al which were established to clinically predict primary nonfunction in normothermically perfused human livers [29]. Briefly, one major and two minor criteria must be met in order to deem the liver clinically viable. As shown in Fig 4, perfused livers containing engineered sensor cells produce bile (Fig 4A), a major criterion; show stable flow rates (Fig 4B) and stable perfusate pH (Fig 4C), two minor criteria. Therefore, it can be suggested that the cell infusion and engraftment would not have an impact on the ability of the liver to successfully survive and function after transplant.
To further assess if the cell infusion did affect function, we assessed several additional parameters during perfusion: Metabolic activity of the liver was additionally tested using glucose stability [23] as well as oxygen consumption rate. Hepatocellular damage was further assessed using and aspartate transaminase (AST) release [30] which we have also shown to be correlated to transplant success in similar normothermic rat liver perfusions systems [31]. Finally, we measured liver weight before and after perfusion to evaluate if there was any edema. In all three groups lactate (Fig 5A) and glucose (Fig 5B) values rose initially but began to stabilize after the perfusate switch at T = 3hrs. Oxygen consumption (Fig 5C) was calculated using O2Consumption=portalflow*S*pO2inflow−pO2outflowgliverweight (S, the solubility constant of water at 37°C = 0.031μL/mL/mm Hg) [15]. Oxygen consumption was found to be higher in the control group due to the higher portal flows. AST production, known to correlate with liver damage, followed a similar trend for all three groups throughout perfusion (Fig 5D). Finally, weight change (Fig 5E) pre- and post-perfusion showed that the engineered fibroblasts did not cause any edema to the liver. Overall, these assays show conclusively that the engrafted biosensor cells did not any negative impact on liver function.
Biosensor cells remain viable and secrete detectable gLuc in external circulation fluids
Biosensor cells were added to perfusate to circulate and engraft in liver, and fresh perfusate without cells was swapped in after 180 minutes to test for engraftment. gLuc has been used as a highly sensitive reporter for assessment of cells in vivo, so levels in the perfusate allow us to track its activity within the rat livers [18, 19, 21]. There was a consistent pattern of gLuc secretion: an initial buildup in the first three hours, then a drop at the time of switching to fresh perfusate, and resumption of increase during hours 4–6. (Fig 6A). Given that the rate of production was similar after the washout period, the data suggest that the initial release of gLuc during the engraftment period represented the adherent, engineered cells within the organ itself rather than being derived from circulating cells.
In order to approximate the number of engrafted cells per tissue, we measured intra-tissue gLuc levels from frozen tissue biopsies compared to a known control sample of pure engineered gLuc fibroblasts. Tissue samples were lysed and the transduced cell group, in comparison to the un-transduced cell group (Negative Control), had significantly higher levels of gLuc secretion (Fig 6B). When compared to a positive control of 1 x 106 pure gLuc cells, the signal coming from a 100mg tissue biopsy was ~13% to that of the positive control. This equates to ~1.3 x 103 engineered cells per mg of tissue. When scaled to a 10g liver, the order of magnitude of engineered cells approaches 107 cells which suggests that nearly the entirety of the infused cell population likely engrafted, albeit greater than expected and likely due to the variability of the assay and assumptions herein.
Discussion
Cell therapy is now an established class of medical therapy with approved products such as chimeric antigen receptor (CAR)-T cells and mesenchymal stromal cells (MSCs) being approved in several jurisdictions around the world. We herein describe the foundation of a strategy to robustly distribute a cell therapy into an organ prior to theoretic transplantation using ex vivo machine perfusion. Our approach using machine perfusion has the advantage of efficiently delivering engineered cells into a designated organ. Simple injection of cells distributed poorly (S1 Fig) and therefore may not be able to represent or cover the entirety of the organ with local diffusion being the major form of molecular transport within a tissue bed. At the clinical level, the introduction of machine perfusion into the transplant surgeons’ workflow has already decreased organ discard rates [32] and is quickly being widely adopted throughout the world. Therefore, machine perfusion is a unique platform for applying therapeutic adjuncts, including cell therapy, to modulate organ function. In this study, we utilized our previously established ex vivo liver perfusion system [20] as a novel platform for engrafting cell biosensors in a pre-transplant model. In confirming the biocompatibility of these cells through liver functionality assays and confirming the efficient delivery of these cells via a normothermic perfusion system, we have developed an efficient platform to further the applications in a transplant dysfunction context. Moreover, since the engraftment of cells does not appear to damage the organ, local cell sensors can also provide a way of monitoring organ quality as a release criteria prior to transplant for the resuscitation of marginal donor organs.
The perfusion system allows for the engraftment of engineered cells into an organ under stable operating conditions for machine perfusion. The time of perfusion for optimal engraftment and minimal ex vivo storage is an area of process development worth improving. Extended perfusion time seems to improve cell distribution to peripheral areas of the organ which can be important to provide comprehensive coverage in the tissue bed to detect local microenvironmental signaling that may only diffuse on the order of 0.1–1 mm in interstitial distance. Varying cell numbers is also worth exploration to evaluate the minimal number of cells necessary to provide local microenvironmental coverage across an organ to impact physiological outcomes. For this purpose, it will be useful to have a diseased organ to use as a testbed in order to find these functional limits. Our initial estimates suggest that 5 x 106 engineered rat fibroblasts provided a good coverage of cell distribution with near total engraftment. An engrafted population of ~103 cells per mg tissue would ensure good sampling of the organ. More detailed analysis of counting engrafted cells can give further precision to this number and can be a quantitative metric to compare against tissue functional outcome data.
Fibroblasts were tested as a first model cell type due to their ease of isolation from allogeneic sources, efficient transduction, and the opportunity to create well-characterized frozen banks for “off-the-shelf” use given the unpredictable timing of transplant surgery. Fibroblasts durably engrafted into the liver and showed robust, engineered protein secretion. Notably, bone marrow derived fibroblastic MSCs are already in widespread use clinically [33], and genetically engineered MSCs as a therapeutic are already in clinical trials [34] easing the regulatory pathway for future purposes. MSCs have also been demonstrated as a therapeutic adjuvant in perfused human kidneys to induce a regeneration response [35]; it is therefore possible to envision future approaches where such innate therapeutic capabilities are combined with sensor functions engineered into the cells. For this initial study, we did not choose MSCs because such existing therapeutic effects would be possible confounding factors when analyzing the viability and function of livers during perfusion.
This study develops the protocols to introduce the engineered fibroblasts into perfused grafts, and demonstrates the cells cause no immediate injury or functional impairment to the livers, and their engineered functions remain stable during 6 hours of perfusion. However long-term transplant studies are necessary to develop optimized protocols to ensure safety and function of biosensor cells in vivo. Such studies would also test the long-term fate of cells, and compare other cell types with engraftment potential into a liver, such as endothelial cells, immune cells, or even hepatocytes themselves as natural considerations. We expect that the in vivo durability and fate of engineered cells could vary significantly between different cell types, and it is also possible that different applications will require different cell types. Other considerations could include additional layers of safety, such as suicide switches that our team and others have developed which can also be incorporated into biosensors for simple elimination after transplantation.
Rejection of liver allografts has decreased with the use of immunosuppressive drugs, but still affects 15 to 25% of liver transplant recipients [36, 37]. Evaluation of the immunosuppression state and early diagnosis of acute or chronic organ rejection remains a crucial task, but such monitoring relies largely on clinical judgment [38]. In the case of liver, current biomarkers of transplant such as ALT and AST have poor sensitivity to detect chronic rejection; it is similarly difficult to easily assess development of graft acceptance [38]. Innate immune cytokines such as interleukins, TNF, and IFN-γ are likely first expressed in tissue before hepatic injury and may be valid detection points for biomarkers [38, 39], especially if they can be sensed locally and in tandem. We envision that this initial work can serve as a foundation for the use of engineered (synthetic) cells meant to be engrafted into an organ prior to transplant to act as an in-situ cell-based biosensor for potentially reporting and responding to the inflammatory state of a graft. Customizing the genetic constructs within this biosensor may also find use in dysfunctional organ donations, like fatty or cirrhotic organs, as a way to expand the donor pool itself.
In summary, a proof-of-concept study was performed to verify the engraftment and function of engineered cells perfused into an ex vivo organ. A feasible process of preparing an engineered cells suspension into an organ preservation solution during machine perfusion was established. This study represents the first ever demonstration of embedding engineered cells within an organ prior to transplant and can serve as the basis for new designer engineered cells for specific in vivo functionality along with improved perfusion and monitoring techniques to control and correlate the bioprocess to surgical outcomes post-transplantation.
Supporting information
S1 Fig [tif]
Bolus injection of cells fails to distribute biosensors throughout organ.
Zdroje
1. Jadlowiec CC, Taner T. Liver transplantation: Current status and challenges. World J Gastroenterol. 2016;22(18):4438–45. Epub 2016/05/18. doi: 10.3748/wjg.v22.i18.4438 27182155; PubMed Central PMCID: PMC4858627.
2. Ten Brinke A, Martinez-Llordella M, Cools N, Hilkens CMU, van Ham SM, Sawitzki B, et al. Ways Forward for Tolerance-Inducing Cellular Therapies- an AFACTT Perspective. Front Immunol. 2019;10:181. Epub 2019/03/12. doi: 10.3389/fimmu.2019.00181 30853957; PubMed Central PMCID: PMC6395407.
3. Cai S, Chandraker A. Cell Therapy in Solid Organ Transplantation. Curr Gene Ther. 2019. Epub 2019/06/05. doi: 10.2174/1566523219666190603103840 31161989.
4. Garakani R, Saidi RF. Recent Progress in Cell Therapy in Solid Organ Transplantation. Int J Organ Transplant Med. 2017;8(3):125–31. Epub 2017/09/20. 28924460; PubMed Central PMCID: PMC5592099.
5. Reinders MEJ, van Kooten C, Rabelink TJ, de Fijter JW. Mesenchymal Stromal Cell Therapy for Solid Organ Transplantation. Transplantation. 2018;102(1):35–43. Epub 2017/07/14. doi: 10.1097/TP.0000000000001879 28704335.
6. Roemhild A, Reinke P. Virus-specific T-cell therapy in solid organ transplantation. Transpl Int. 2016;29(5):515–26. Epub 2015/08/19. doi: 10.1111/tri.12659 26284570.
7. Haarer J, Johnson CL, Soeder Y, Dahlke MH. Caveats of mesenchymal stem cell therapy in solid organ transplantation. Transpl Int. 2015;28(1):1–9. Epub 2014/08/02. doi: 10.1111/tri.12415 25082213.
8. Govender L, Pascual M, Golshayan D. Potential and limitations of regulatory T-cell therapy in solid organ transplantation. Expert Rev Clin Immunol. 2014;10(9):1197–212. Epub 2014/07/31. doi: 10.1586/1744666X.2014.943191 25073810.
9. Dahlke MH. Immunomodulative cell therapy after solid organ transplantation: which cell type when? Curr Opin Organ Transplant. 2012;17(1):33. Epub 2012/01/10. doi: 10.1097/MOT.0b013e32834f02de 22227720.
10. Fandrich F. Cell therapy approaches aiming at minimization of immunosuppression in solid organ transplantation. Curr Opin Organ Transplant. 2010;15(6):703–8. Epub 2010/10/12. doi: 10.1097/MOT.0b013e328340669a 20930635.
11. Hoogduijn MJ, Popp FC, Grohnert A, Crop MJ, van Rhijn M, Rowshani AT, et al. Advancement of mesenchymal stem cell therapy in solid organ transplantation (MISOT). Transplantation. 2010;90(2):124–6. Epub 2010/07/08. doi: 10.1097/TP.0b013e3181ea4240 20606604.
12. Sprangers B, DeWolf S, Savage TM, Morokata T, Obradovic A, LoCascio SA, et al. Origin of Enriched Regulatory T Cells in Patients Receiving Combined Kidney-Bone Marrow Transplantation to Induce Transplantation Tolerance. Am J Transplant. 2017;17(8):2020–32. Epub 2017/03/03. doi: 10.1111/ajt.14251 28251801; PubMed Central PMCID: PMC5519438.
13. Sasaki H, Oura T, Spitzer TR, Chen YB, Madsen JC, Allan J, et al. Preclinical and clinical studies for transplant tolerance via the mixed chimerism approach. Hum Immunol. 2018;79(5):258–65. Epub 2017/11/28. doi: 10.1016/j.humimm.2017.11.008 29175110; PubMed Central PMCID: PMC5963722.
14. Slomovic S, Pardee K, Collins JJ. Synthetic biology devices for in vitro and in vivo diagnostics. Proc Natl Acad Sci U S A. 2015;112(47):14429–35. Epub 2015/11/26. doi: 10.1073/pnas.1508521112 26598662; PubMed Central PMCID: PMC4664311.
15. Reinders ME, Hoogduijn MJ. NK Cells and MSCs: Possible Implications for MSC Therapy in Renal Transplantation. J Stem Cell Res Ther. 2014;4(2):1000166. Epub 2014/06/06. doi: 10.4172/2157-7633.1000166 24900946; PubMed Central PMCID: PMC4040539.
16. Ichim TE, O'Heeron P, Kesari S. Fibroblasts as a practical alternative to mesenchymal stem cells. J Transl Med. 2018;16(1):212. Epub 2018/07/29. doi: 10.1186/s12967-018-1536-1 30053821; PubMed Central PMCID: PMC6064181.
17. Tannous BA, Kim DE, Fernandez JL, Weissleder R, Breakefield XO. Codon-optimized Gaussia luciferase cDNA for mammalian gene expression in culture and in vivo. Mol Ther. 2005;11(3):435–43. doi: 10.1016/j.ymthe.2004.10.016 15727940.
18. Elman JS, Murray RC, Wang F, Shen K, Gao S, Conway KE, et al. Pharmacokinetics of natural and engineered secreted factors delivered by mesenchymal stromal cells. PLoS One. 2014;9(2):e89882. Epub 2014/03/04. doi: 10.1371/journal.pone.0089882 24587097; PubMed Central PMCID: PMC3931832.
19. Singleton A, Khong D, Chin LY, Mukundan S, Li M, Parekkadan B. An engineered biomarker system to monitor and modulate immune clearance of cell therapies. Cytotherapy. 2017;19(12):1537–45. Epub 2017/09/18. doi: 10.1016/j.jcyt.2017.08.003 28917628; PubMed Central PMCID: PMC5723229.
20. Karimian N, Yeh H. Opportunities for Therapeutic Intervention During Machine Perfusion. Curr Transplant Rep. 2017;4(2):141–8. Epub 2017/11/08. doi: 10.1007/s40472-017-0144-y 29109929; PubMed Central PMCID: PMC5669266.
21. Tannous BA. Gaussia luciferase reporter assay for monitoring biological processes in culture and in vivo. Nat Protoc. 2009;4(4):582–91. doi: 10.1038/nprot.2009.28 19373229; PubMed Central PMCID: PMC2692611.
22. Lin P, Lin Y, Lennon DP, Correa D, Schluchter M, Caplan AI. Efficient lentiviral transduction of human mesenchymal stem cells that preserves proliferation and differentiation capabilities. Stem Cells Transl Med. 2012;1(12):886–97. Epub 2013/01/04. doi: 10.5966/sctm.2012-0086 23283550; PubMed Central PMCID: PMC3659678.
23. Delriviere L, Gibbs P, Kobayashi E, Goto S, Kamada N, Gianello P. Detailed modified technique for safer harvesting and preparation of liver graft in the rat. Microsurgery. 1996;17(12):690–6. Epub 1996/01/01. doi: 10.1002/(SICI)1098-2752(1996)17:12<690::AID-MICR6>3.0.CO;2-R 9588714.
24. Tolboom H, Pouw R, Uygun K, Tanimura Y, Izamis ML, Berthiaume F, et al. A model for normothermic preservation of the rat liver. Tissue Eng. 2007;13(8):2143–51. Epub 2007/06/29. doi: 10.1089/ten.2007.0101 17596120.
25. Berendsen TA, Bruinsma BG, Lee J, D'Andrea V, Liu Q, Izamis ML, et al. A simplified subnormothermic machine perfusion system restores ischemically damaged liver grafts in a rat model of orthotopic liver transplantation. Transplant Res. 2012;1(1):6. Epub 2013/02/02. doi: 10.1186/2047-1440-1-6 23369351; PubMed Central PMCID: PMC3552573.
26. Wurdinger T, Badr C, Pike L, de Kleine R, Weissleder R, Breakefield XO, et al. A secreted luciferase for ex vivo monitoring of in vivo processes. Nat Methods. 2008;5(2):171–3. Epub 2008/01/22. doi: 10.1038/nmeth.1177 18204457; PubMed Central PMCID: PMC2699561.
27. Teng J, Hejazi S, Badr CE, Tannous BA. Systemic anticancer neural stem cells in combination with a cardiac glycoside for glioblastoma therapy. Stem Cells. 2014;32(8):2021–32. Epub 2014/05/08. doi: 10.1002/stem.1727 24801379.
28. Schofield ZV, Woodruff TM, Halai R, Wu MC, Cooper MA. Neutrophils—a key component of ischemia-reperfusion injury. Shock. 2013;40(6):463–70. Epub 2013/10/04. doi: 10.1097/SHK.0000000000000044 24088997.
29. Mergental H, Stephenson BTF, Laing RW, Kirkham AJ, Neil DAH, Wallace LL, et al. Development of Clinical Criteria for Functional Assessment to Predict Primary Nonfunction of High-Risk Livers Using Normothermic Machine Perfusion. Liver Transpl. 2018;24(10):1453–69. Epub 2018/10/26. doi: 10.1002/lt.25291 30359490; PubMed Central PMCID: PMC6659387.
30. Imber CJ, St Peter SD, Lopez de Cenarruzabeitia I, Pigott D, James T, Taylor R, et al. Advantages of normothermic perfusion over cold storage in liver preservation. Transplantation. 2002;73(5):701–9. Epub 2002/03/22. doi: 10.1097/00007890-200203150-00008 11907414.
31. Uygun K, Tolboom H, Izamis ML, Uygun B, Sharma N, Yagi H, et al. Diluted blood reperfusion as a model for transplantation of ischemic rat livers: alanine aminotransferase is a direct indicator of viability. Transplant Proc. 2010;42(7):2463–7. Epub 2010/09/14. doi: 10.1016/j.transproceed.2010.04.037 20832525; PubMed Central PMCID: PMC3020900.
32. Nasralla D, Coussios CC, Mergental H, Akhtar MZ, Butler AJ, Ceresa CDL, et al. A randomized trial of normothermic preservation in liver transplantation. Nature. 2018;557(7703):50–6. Epub 2018/04/20. doi: 10.1038/s41586-018-0047-9 29670285
33. Trounson A, McDonald C. Stem Cell Therapies in Clinical Trials: Progress and Challenges. Cell Stem Cell. 2015;17(1):11–22. Epub 2015/07/04. doi: 10.1016/j.stem.2015.06.007 26140604.
34. Petrou P, Gothelf Y, Argov Z, Gotkine M, Levy YS, Kassis I, et al. Safety and Clinical Effects of Mesenchymal Stem Cells Secreting Neurotrophic Factor Transplantation in Patients With Amyotrophic Lateral Sclerosis: Results of Phase 1/2 and 2a Clinical Trials. JAMA Neurol. 2016;73(3):337–44. Epub 2016/01/12. doi: 10.1001/jamaneurol.2015.4321 26751635.
35. Brasile L, Henry N, Orlando G, Stubenitsky B. Potentiating Renal Regeneration Using Mesenchymal Stem Cells. Transplantation. 2019;103(2):307–13. Epub 2018/09/21. doi: 10.1097/TP.0000000000002455 30234788; PubMed Central PMCID: PMC6347512.
36. Gruttadauria S, Vasta F, Mandala L, Cintorino D, Piazza T, Spada M, et al. Basiliximab in a triple-drug regimen with tacrolimus and steroids in liver transplantation. Transplant Proc. 2005;37(6):2611–3. Epub 2005/09/27. doi: 10.1016/j.transproceed.2005.06.063 16182762.
37. Maluf DG, Stravitz RT, Cotterell AH, Posner MP, Nakatsuka M, Sterling RK, et al. Adult living donor versus deceased donor liver transplantation: a 6-year single center experience. Am J Transplant. 2005;5(1):149–56. Epub 2005/01/08. doi: 10.1111/j.1600-6143.2004.00654.x 15636624.
38. Germani G, Rodriguez-Castro K, Russo FP, Senzolo M, Zanetto A, Ferrarese A, et al. Markers of acute rejection and graft acceptance in liver transplantation. World J Gastroenterol. 2015;21(4):1061–8. Epub 2015/01/30. doi: 10.3748/wjg.v21.i4.1061 25632178; PubMed Central PMCID: PMC4306149.
39. Verhelst XP, Troisi RI, Colle I, Geerts A, van Vlierberghe H. Biomarkers for the diagnosis of acute cellular rejection in liver transplant recipients: A review. Hepatol Res. 2013;43(2):165–78. Epub 2012/11/29. doi: 10.1111/hepr.12012 23186289
Článok vyšiel v časopise
PLOS One
2019 Číslo 12
- Metamizol jako analgetikum první volby: kdy, pro koho, jak a proč?
- Nejasný stín na plicích – kazuistika
- Masturbační chování žen v ČR − dotazníková studie
- Těžké menstruační krvácení může značit poruchu krevní srážlivosti. Jaký management vyšetření a léčby je v takovém případě vhodný?
- Fixní kombinace paracetamol/kodein nabízí synergické analgetické účinky
Najčítanejšie v tomto čísle
- Methylsulfonylmethane increases osteogenesis and regulates the mineralization of the matrix by transglutaminase 2 in SHED cells
- Oregano powder reduces Streptococcus and increases SCFA concentration in a mixed bacterial culture assay
- The characteristic of patulous eustachian tube patients diagnosed by the JOS diagnostic criteria
- Parametric CAD modeling for open source scientific hardware: Comparing OpenSCAD and FreeCAD Python scripts