Limits in reliability of leg-spring and joint stiffness measures during single-leg hopping within a sled-based system
Authors:
David Diggin aff001; Ross Anderson aff002; Andrew J. Harrison aff002
Authors place of work:
Department of Exercise Science and Athletic Training, Ithaca College, Ithaca, New York, United States of America
aff001; Biomechanics Research Unit, Department of Physical Education and Sport Sciences, University of Limerick, Limerick, Ireland
aff002
Published in the journal:
PLoS ONE 14(12)
Category:
Research Article
doi:
https://doi.org/10.1371/journal.pone.0225664
Summary
Research examining the reliability of stiffness measures during hopping has shown strong consistency in leg-spring stiffness (kleg), but high variability in joint stiffness (kjoint) measures. Sled-based systems (SBS) reduce movement degrees-of-freedom and are used to examine stretch-shortening cycle (SSC) function under controlled conditions. The aim of this study was to examine the reliability of kleg and kjoint during single-leg hopping within an SBSKinematic and kinetic data were collected on four occasions (Day_1, Day_2, Day_3 and Day_3Offset). Participants completed two trials of single-leg hopping at different frequencies (1.5, 2.2 and 3.0 Hz) while attached to an inclined-SBS. Stiffness was determined using models of leg-spring (kleg) and torsional (kjoint) stiffness. Statistical analysis identified absolute and relative measures of reliability. Results showed moderate reliability for kleg at 1.5 Hz between inter-day testing bouts, and weak consistency at 2.2 and 3.0 Hz. Examination of intra-day comparisons showed weak agreement for repeated measures of kleg at 1.5 and 2.2 Hz, but moderate agreement at 3.0 Hz. Limits in kleg reliability were accompanied by weak-to-moderate agreement in kjoint measures across inter- and intra-day testing bouts. Results showed limits in the reliability of stiffness measures relative to previous reports on overground hopping. Lack of consistency in kleg and kjoint may be due to the novelty of hopping within the current inclined-SBS. Constraints imposed on the hopping task resulting from SBS design (e.g. additional chair mass, restricting upper body movement) may have also influenced limits in kleg and kjoint reliability. Researchers should consider these findings when employing inclined-SBS of a similar design to examine SSC function.
Keywords:
musculoskeletal system – Hip – Knee joints – Ankle joints – Stiffness – Research validity – kinematics – Ankles
Introduction
Stretch-shortening cycle (SSC) tasks are characterised by eccentric lengthening immediately followed by concentric shortening [1]. These actions are typical of human movement (e.g. walking, running, jumping and throwing) and serve to enhance concentric force output and movement efficiency [1,2]. Knowledge of mechanisms controlling SSC function are therefore relevant to general health and athletic performance. SSC function has subsequently been examined during walking [3], running [4,5], jumping [4], under fatigued conditions [6–10] and before and after training [11,12].
It is understood that the efficiency of SSC task performance is regulated by a combination of elastic and neural mechanisms [1]. Of importance to elastic mechanisms of SSC performance is the property stiffness (k). Stiffness represents the resistance of a body to deformation and reflects the elastic nature of the body [13,14]. In humans, greater stiffness is found to enhance the operational effectiveness of the SSC [15–17], yet higher levels of stiffness also contribute to musculoskeletal injury [18]. When examining stiffness characteristics during SSC tasks, researchers often model the elastic nature of the entire leg as a linear-spring (i.e. kleg) [9,19–22]. Torsional stiffness models are also used to clarify the contribution of the stiffness of each joint (kjoint) to kleg [7].
The reliability of kleg and kjoint measures has been examined during SSC tasks [22,23]. During double- and single-leg hopping, Joseph et al. [23] and Diggin et al. [22] showed good agreement (ICC > 0.80) for repeated measures of kleg when hopping frequency is controlled. In contrast, measurement consistency declined (ICC = 0.20–0.86) during running and hopping at self-selected frequencies [23]. Furthermore, kjoint measures have consistently demonstrated questionable reliability during natural hopping and running tasks. Joseph et al. [23] showed poor reliability for all kjoint variables measured (ICC = 0.51–0.92; CV > 20%). Diggin and colleagues [22] showed strong consistency for repeated measures of kankle, but weak-to-moderate agreement for kknee and khip (ICC = 0.57–0.93) during single-leg hopping. It must be noted that in efficient SSC tasks (e.g. hopping), participants must coordinate the body’s musculoskeletal structures (e.g. segments, muscles, joints) in an integrated fashion to achieve the movement goal. These requirements produce inherent variability in movement patterns which can impact movement consistency and measurement reliability [24]. It is possible that limits in kleg and kjoint reliability previously reported, were caused by extraneous movements (esp. upper body) that impacted landing consistency.
Researchers have used sled-based systems (SBS) to offset issues associated with extraneous upper body movements [8,19,25,26]. While construction varies between laboratories, these systems often include rails positioned at angles below vertical orientation (e.g. 0°–30° to horizontal) [12,27]. A force plate mounted at the end of the system provides kinetic information of participants’ performance [6,25,28]. Participants perform SSC tasks (e.g. drop / rebound jumps, hopping) while attached to a chair / platform (sled) that slides up and down the inclined rails. SBS regulate levels of mechanical load experienced during SSC tasks by (i) altering rail angle [27]; (ii) employing a winch system to control initial eccentric loading [19,29]; and (iii) reducing movement degrees-of-freedom [10,30]. For lower body SBS, performance of SSC tasks while attached to the chair limits upper body movement and allows researchers to control impact velocities and eccentric loading [8,19]. Furthermore, the restricted path of the sledge chair might reduce task constraints and facilitate consistent landing patterns which can impact measurement reliability.
The reliability of kinematic and kinetic variables measured during SSC task performance within an SBS has been examined. Debenham and colleagues [10] reported strong agreement (ICC = 0.87) for ankle joint range-of-motion recorded during single-leg hopping tasks within an SBS. During drop (DJ) and rebound jump (RBJ) tasks, Flanagan and Harrison [19] reported strong consistency (Cronbach’s α > 0.95) for temporal and kinetic variables tested (e.g. flight time, Fz max, reactive strength index). Similarly, during a simulated hopping task within an SBS, Furlong and Harrison [29] reported strong consistency (Cronbach’s α > 0.90) for temporal (CT, flight time) and kinetic (e.g. Fz max, peak rate of force development) variables. Flanagan and Harrison [19] reported strong reliability (Cronbach’s α > 0.95) for repeated measures of kleg during jumping tasks (Cronbach’s α > 0.95) within an SBS.
Given the purpose of the SBS is to reduce extraneous upper body movement to encourage landing and measurement consistency, it is possible that stiffness measures (esp. kjoint) achieved during hopping within an SBS might demonstrate strong reliability. To date, the consistency of kleg and kjoint measures recorded during hopping within an SBS has not been examined. The aim of this study was to examine the reliability of stiffness measures during hopping within an inclined-SBS. It was hypothesized that restricting extraneous upper body movement would facilitate strong consistency for kleg and kjoint variables during hopping tasks.
Materials and methods
Participant characteristics
Thirty-two students (16 males and 16 females; mean ± SD age 21.3 ± 2.9 years; stature 1.70 ± 0.08 m; mass 69.9 ± 10.0 kg) volunteered to participate. Volunteers were recruited via e-mail circulated to the campus community. All participants were physically active as members of a university sports club, attending bi-weekly practices and represented the university at varsity level. Participants were injury free for at least six months prior to testing as determined via health screening questionnaire. Procedures were approved by the research ethics committee of the Faculty of Education and Health Science at the University of Limerick, and all participants provided written informed consent. To limit the effects of fatigue on stiffness measurement, participants were instructed to abstain from vigorous physical activity 24 hours before testing bouts.
Experimental procedures
Participants completed a familiarization session one week prior to initial testing to acquaint them with procedures (Day_0) [31]. Following this, participants underwent testing on four occasions. The first (Day_1), second (Day_2) and third (Day_3) testing bouts took place at the same time of day, spaced three to seven days apart [23,32]. On the final test day, participants completed procedures twice; at their typically scheduled time (Day_3) and six hours prior to or following their scheduled time (Day_3Offset) [22].
For each test, participants wore dark, tight-fitting clothing. Retro-reflective markers (14 mm) were placed at six anatomical locations on participants’ right side (acromion process, greater trochanter, lateral epicondyle of the femur, lateral malleolus, calcaneus and fifth metatarsal). Marker placement was conducted by the same tester throughout for consistency. During all test bouts (Day_0 –Day_3), participants completed two 10 second trials of single-leg hopping at each of 1.5, 2.2 and 3.0 Hz in time with a digital metronome (TempoPerfect Metronome, NCH Software, Greenwood Village, CO, USA) while secured within an SBS (Fig 1). The design of the SBS was described previously [12,19]. As previous research suggests little effect of leg dominance on kleg or kjoint [23], participants were instructed to land as close as possible to the force plate center (AMTI OR6-5; AMTI, Watertown, MA, USA) in time with the metronome, using their right leg and natural hopping technique. Trials were accepted for analysis if participants hopped within ± 5% of the target frequency [33,34]. The order of hopping trials was randomly assigned, and participants received 60 seconds recovery between each trial to limit fatigue effects. An analogue triggering device was used to initiate 3D kinematic and kinetic data acquisition simultaneously. Kinematic data were recorded using three MAC Eagle cameras (MotionAnalysis Corporation, Santa Rosa CA, USA) operating at 200 Hz. Kinetic data were recorded at 1 kHz over the 10 second duration.
Data processing
Analysis of data revealed an inconsistent delay in the initiation of kinematic and kinetic recordings. Whittlesey and Robertson [35] noted that kinematic and kinetic input signals must be temporally aligned to facilitate valid inverse dynamics analysis. Work in our laboratory has shown that maximum rate of change in fifth metatarsal marker acceleration profiles (i.e. peak jerk), coincide with ground contact to within 3.83 (± 1.06) ms of force plate criterion measures during overground hopping. Fifth metatarsal vertical coordinate data were subsequently differentiated to jerk [36]. The time of peak jerk was determined, and kinematic data were subsequently aligned with the time at which the vertical force increased above 5 N.
Marker trajectories were digitized using Cortex motion analysis software (version 2.1; MotionAnalysis Corporation, Santa Rosa, CA, USA). 3D kinematic and kinetic data were subsequently exported and analyzed using customized MS Excel macros. Recorded kinematic and kinetic data were concurrently filtered using a fourth-order Butterworth Low-Pass digital filter with an optimal cut-off of 11 Hz determined via residual analysis [36]. 3D coordinate data were subsequently interpolated to 1 kHz using a cubic spline. Filtered kinematic and kinetic data were used to calculate resultant joint moments occurring about ankle (Mankle), knee (Mknee) and hip (Mhip) joints throughout the ground contact phase of each trial using inverse dynamics [7,23,37]. Segment inertia and mass characteristics were determined using the standards of Dempster [38]. Having calculated resultant moments, average torsional stiffness of the ankle (kankle), knee (kknee) and hip (khip) were calculated as a ratio of changes in joint moment (ΔMjoint) and angle (Δϴjoint) for respective lower limb joints [7,23].
In addition, kleg was recorded throughout the ground contact phase of all hopping trials using the spring-mass model [21]. Thus kleg was calculated as the ratio of Fz max and maximum leg compression (ΔLegL) occurring during ground contact as measured from video records [39], where leg length represented the distance between the greater trochanter and the center-of-force [40]. In all analyzed trials, the temporal occurrence of discrete events of Fz max and ΔLegL coincided to within 10% of the hop period.
Statistical analysis
The mean of 5 consecutive hops occurring within the middle of each 10-second trial was calculated for dependent variables and compared within and between experimental bouts. Differences between the means recorded for each experimental bout were established for each hopping frequency (HopFreq) using repeated measures ANOVA (parametric variables) or Friedman’s test (non-parametric variables). Reliability analysis employed both ‘absolute’ and ‘relative’ measures. A two-way random effects intra-class correlation coefficient (ICC) model examined the relative agreement between parametric and log-transformed dependent variables, while measurement consistency was established from effect size (ES) and ICC 95% confidence interval results [31,41,42]. Variables were considered strong when ICC ≥ 0.90 [43], the lower-bound level of the ICC 95% confidence interval (ICCLower) > 0.80 [31] and Cohen’s ES < 0.50 (moderate effect) [44]. Moderate reliability occurred if ICC ranged from 0.80 to 0.89, ICCLower ≥ 0.70 and ES < 0.50, while ‘weak’ reliability occurred if the previous criteria were not met. Within-participant variation in dependent variables were also examined using typical error (TE) [41], however these statistics were not included in reliability indexing. All statistical analysis was conducted using SPSS (version 23.0, IBM Corporation, Armonk, NY, USA).
Results
Results for control variables of contact time (CT; F (1.3, 3.9) = 2.14; p > 0.05), flight time (FT; F (1.7, 5.0) = 2.84; p > 0.05) and HopFreq (F (1.8, 5.3) = 0.56; p > 0.05; Table 1) revealed no significant difference between means for these variables across inter-day testing bouts. Reliability analysis showed strong agreement for variables of CT and FT (ICC = 0.95–0.97; ICCLower = 0.81–0.92; ES = 0.01–0.09) at 1.5 and 3.0 Hz with moderate reliability evident at 2.2 Hz (ICC = 0.94; ICCLower = 0.79–0.92; ES = 0.10). Across intra-day testing bouts, analysis revealed no significant difference in CT (F (2, 18) = 0.10; p > 0.05), FT (F (2, 18) = 0.29; p > 0.05) and HopFreq (F (1.6, 43.6) = 1.24; p > 0.05) when measured six-hours apart. The high ICC’s (0.92–0.98), moderate-to-high ICCLower coefficients (0.82–0.96) and low ES (0.04–0.13), suggest ‘strong’ intra-day agreement for variables of FT and CT. Despite moderate-to-strong reliability indices for FT and CT variables, HopFreq exhibited weak consistency throughout.
Friedman’s test revealed no significant change in kleg (χ2 (5) = 0.68–10.23; p > 0.05) across Day_1, Day_2 and Day_3 testing bouts at any HopFreq. Despite exhibiting little change between days, reliability indices showed kleg exhibited weak-to-moderate consistency (ICC = 0.71–0.89; ICCLower = 0.29–0.73; ES = 0.08–0.26) between inter-day bouts across all HopFreq (Table 2). Examination of kinematic and kinetic variables (Table 3) shows limits in kleg measurement agreement originated from limits in Fz max and ΔLegL measurement consistency. Limits in kleg measurement agreement, were accompanied by weak consistency in kknee and khip between Day_1, Day_2 and Day_3 across all HopFreq (ICC = 0.62–0.84; ICCLower = 0.02–0.61; ES = 0.10–0.70). Only kankle exhibited moderate-to-strong consistency at slower HopFreq (ICC = 0.91–0.94; ICCLower = 0.76–0.83; ES = 0.17–0.18). Examination of kinematic and kinetic variables (Table 3) shows that despite limits to kknee and khip at 1.5 Hz, participants exhibited weak-to-strong consistency for joint kinetic and kinematic variables. At 2.2 and 3.0 Hz, limits in kknee and khip resulted from weak-to-moderate agreement for joint kinetics and kinematics. Data show that strong consistency in kankle measures at 1.5 Hz was accompanied by strong consistency in Mankle max and Δϴankle. Limits in kankle measurement agreement at 2.2 and 3.0 Hz were accompanied by varied consistency in ankle kinematic and kinetic measures. Joint kinetics and kinematics showed no change (p > 0.05) between inter-day test bouts at any hopping frequency.
Examination of intra-day testing comparisons (Table 2) showed no change in kleg between Day_3 and Day_3Offset (χ2 (3) = 0.60–3.19; p > 0.05). Despite this, kleg measures exhibited weak consistency at 1.5 and 2.2 Hz HopFreq (ICC = 0.59–0.86; ICCLower = 0.09–0.70; ES = 0.11–0.35) and moderate consistency at 3.0 Hz (ICC = 0.87; ICCLower = 0.71; ES = 0.17). Limits in kleg reliability originated from strong and weak consistency in Fz max and ΔLegL respectively at all HopFreq. Repeated measure ANOVA results showed no change in kjoint variables between Day_3 and Day_3Offset (F (1.1, 22.6) = 0.17–1.07; p > 0.05). Despite this, kknee and khip exhibited weak-to-moderate consistency between Day_3 and Day_3Offset (ICC = 0.29–0.89; ICCLower = 0.00–0.72; ES = 0.02–0.50). In contrast, kankle exhibited strong consistency at 3.0 Hz but weak consistency at other hopping frequencies. Examination of kinematic and kinetic data (Table 4) showed limits in kjoint reliability originated from largely weak-to-moderate consistency in joint kinematic and kinetic inputs between Day_3 and Day_3Offset. Limits in consistency in kinematic and kinetic inputs occurred despite no change in these data between Day_3 and Day_3Offset testing bouts (χ2 (3) = 0.98–3.86; p > 0.05).
Discussion
SBS are used to examine SSC function under controlled conditions. Sled design regulates eccentric loading and limits extraneous movement to improve landing and measurement consistency. During overground hopping and running, kleg has demonstrated good reliability [22,23]. In contrast, kjoint measures have demonstrated limited consistency. The reliability of kleg and kjoint while hopping within an SBS had not been examined. This study provides a comprehensive analysis of the inter- and intra-day reliability of kleg and kjoint achieved during hopping within an SBS.
Similar to the findings of Hobara and colleagues [21] kleg and kjoint increased with increases in HopFreq in the present study. Values of 13.9–28.9 kN.m-1 have been reported for kleg during natural hopping conditions on different surfaces and at different frequencies [22,23,30,45,46]. In addition, values of 6.9–12.0 Nm.deg-1 have been reported for kankle during natural hopping [45]. In the present study, stiffness values are lower than reported during natural hopping [22,23]. This can be explained by the orientation of the frame of the SBS (i.e. 30° to the horizontal) which reduces (half) the effect of gravitational acceleration [12,19]. Therefore, lower ground reaction forces (i.e. Fz max) are expected in the present study relative to published reports on overground hopping. This is supported by the work of Harrison et al. [25] and Flanagan and Harrison [19] who reported lower values for kleg during DJ and RBJ tasks (3.4–8.5 kN.m-1) performed within the current SBS, relative to natural conditions. The stiffness data recorded during the present study are in line with previous data reported for SSC tasks performed within an inclined-SBS.
Hobara et al. [21] showed increases in kleg with increases in HopFreq. Thus, regulation of HopFreq between testing bouts was important to reliability analysis. In the current study HopFreq displayed weak-to-moderate consistency across all trials despite CT and FT variables showing strong agreement at all HopFreq between Day_3 and Day_3Offset. Inter-day comparisons showed strong consistency for CT throughout. In contrast, FT exhibited strong agreement at 1.5 and 3.0 Hz but moderate consistency at 2.2 Hz. Hopkins and colleagues [41] suggested low ICC’s occur in situations where between participant variation is low for a given variable. In the present study, HopFreq was regulated to within 5% of the target frequency. Thus, low levels of variability may have produced spurious reliability indices in HopFreq and in FT measures during hopping at 2.2 Hz. The low TE (0.01–0.02) and ES (≤ 0.31) for CT, FT and HopFreq support this. Thus, HopFreq was controlled adequately throughout.
Despite regulation of HopFreq in the present study, kleg exhibited moderate reliability at 1.5 Hz and weak reliability at 2.2 and 3.0 Hz (ICC = 0.59–0.89) between inter-day test bouts. These reliability indexes were accompanied by strong consistency for kankle at 1.5 Hz only. Remaining kjoint variables demonstrated weak-to-moderate agreement between Day_1, Day_2 and Day_3 testing bouts. Between Day_3 and Day_3Offset, kleg exhibited moderate reliability at 3.0 Hz but weak consistency at the other frequencies. The moderate index for kleg at 3.0 Hz was accompanied by strong consistency for kankle. Variables of kknee and khip however, exhibited weak-to-moderate consistency throughout. Examination of kinematic and kinetic inputs (Tables 3 and 4) showed that limits in kleg reliability occurred due to limits in ΔLegL reliability, while Fz max exhibited moderate-to-strong consistency. The present data also showed that limits in kjoint measurement agreement resulted from inconsistencies in Mjoint max and Δϴjoint at the highest hopping frequencies (2.2 and 3.0 Hz).
While the present study did not include a control condition, previous work in our lab examined the reliability of kleg and kjoint measures in overground hopping [22]. This study employed the same methodology and used physically active participants consistent with the current work. Our work showed strong agreement (ICC = 0.95–0.98) for kleg and kankle measures at different hopping frequencies [22]. In contrast, kknee and khip exhibited weak-to-moderate agreement. Given our previous findings, that many stiffness variables showed weak-to-moderate agreement in the present study is surprising. Particularly since the primary function of the current inclined-SBS is to limit extraneous upper body movement to enhance landing and measurement consistency during SSC tasks [8,19].
It is understood that in biological measurement, observed scores are composed of a true score and additional error [42]. Weir [42] suggests that errors in measurement data result from instrumentation errors associated with equipment used, in addition to participant / tester error, modelling error and biological variability. In the context of the current work, instrumentation errors arise from equipment (force plate and video) use and protocol adherence between testing bouts. It is important to note that participants were instructed refrain from physical activity prior to data collection. Furthermore, force plate and video equipment were calibrated as per the manufacturer’s guidelines prior to each data collection period. In addition, equipment set-up and protocols used were consistent with published works showing strong reliability for kleg and kankle during overground hopping [22]. Consequently, deteriorations in measurement consistency relative to published reports are not due to differences in testing protocols between studies.
Of additional concern to the reliability of kleg and kjoint scores is error derived from the use of mathematical models. Whittlesey and Hammill [47] noted that models are sensitive to the number of model components. Thus, small errors present early in the modelling process will propagate by the end of the simulation. This suggests that modelling errors will increase as calculations progress from distal to proximal joints. As kjoint is the ratio of changes in Mjoint and ϴjoint, it is clear that errors in Mjoint (and kknee and khip) measures will increase as inverse dynamics analysis progresses from distal to proximal joints. It is important to consider that while these errors will influence kjoint consistency, they are unlikely to influence kleg in the present work. In addition, as modelling procedures employed in the current work are consistent with previous works [22], it is unlikely that differences in measurement consistency between the current and previous works result from modelling errors.
Considering biological variability, our previous work on overground hopping noted the existence of kleg as an attractor state [22] where participants are drawn to the manipulation of leg compression (seen by variable kjoint or ΔLegL) to maintain a consistent kleg under variable landing conditions [9,45]. These works also showed that stiffness variables were accompanied by mostly strong consistency for Fz max and ΔLegL variables. In the present study, it must be considered that while the reliability of Fz max was strong, the reliability of ΔLegL was weak-to-moderate across all testing bouts. As a result, the kleg exhibited weak-to-moderate consistency throughout. It is therefore difficult to establish a consistent outcome variable (i.e. attractor state) that participants are trying to regulate. Furthermore, considering limits in the reliability of kinematic and kinetic variables measured, and the limited pattern to the nature of this reliability, we feel that our data does not support the notion that limits in reliability are due to kinematic variability to achieve consistent outcomes.
It is important to consider the novelty of the hopping task and its impact on the present data. Our previous work showed that familiarizing participants with testing procedures prior to data collection enhanced measurement reliability relative to earlier reports [23]. In the present study however, participants completed a familiarization session prior to data collection. Thus, acquainting participants with procedures did not benefit the consistency of hopping dynamics within the current SBS. One reason for this is likely the design of the current SBS. The design of the current SBS requires participants to adopt a flexed torso position while secured to it. This novel hopping position would alter the functional length of lower limb musculature compared to upright hopping, which will have impacted participants’ ability to achieve consistent hopping dynamics. In addition, the mass of the chair of the current SBS was 19.6 kg. The added mass may have made it difficult for participants to achieve consistency in their hopping patterns. This is partly supported by the work of Kramer et al. [48]. The authors demonstrated that participants achieved almost natural reactive jumps following this four-week period (i.e. 12 sessions). While the instructions regarding landing dynamics differed from the current study, the design of the lightweight sled (5 kg) allowed participants to adopt natural movement patterns [27,48]. Although the authors did not report reliability indices for variables measured, the changes seen (38% increase) following four weeks of training (i.e. familiarizing) suggest the performance of SSC tasks within an SBS to be a novel task requiring extensive participant familiarization. The practicalities of including multiple familiarization sessions prior to data collection must also be considered.
Considering the lack of reliability evident in kinematics, kinetics and stiffness variables measured, it is appropriate to accept the null hypothesis. Limiting extraneous upper body movement by using an SBS during single-leg hopping did not improve the reliability of kleg and kjoint measures relative to previous reports on overground hopping. In fact, use of the current SBS reduced consistency of stiffness measures relative to previous reports on natural conditions.
Conclusions
To summarize, the present data showed weak-to-moderate reliability for all stiffness measures during hopping using the current SBS. This was due largely to inconsistencies in leg compression (ΔLegL). Thus, reducing extraneous upper body movement using the current SBS did not encourage consistent stiffness regulation. In fact, hopping within the current inclined-SBS had adverse effects on measurement consistency relative to published reports on overground hopping. Limits in the consistency of stiffness measures may be due to constraints imposed by restricting upper body movement, which introduced novelty to the single-leg hopping task. A single familiarization session was therefore inadequate to achieve consistent landing mechanics. The influence of sled design on the current findings must also be considered, with chair mass and orientation likely making it difficult for participants to achieve consistent hopping patterns. Researchers should consider these findings and endeavour to construct a light-weight system with a chair orientation that replicates the functional length of the muscle-tendon units driving the SSC task being analysed.
Zdroje
1. Komi PV, Nicol C. Stretch-shortening cycle of muscle function. In: Neuromuscular Aspects of Sport Performance. 2011. p. 15–31.
2. Kopper B, Csende Z, Sáfár S, Hortobágyi T, Tihanyi J. Muscle activation history at different vertical jumps and its influence on vertical velocity. J Electromyogr Kinesiol. 2013;23(1):132–9. doi: 10.1016/j.jelekin.2012.09.005 23107911
3. Komi PV, Gollhofer A. Stretch reflexes can have an important role in force enhancement during SSC exercise. J Appl Biomech. 1997 Nov;13(4):451–60.
4. Bosco C, Ito A, Komi P, Luhtanen P, Rahkila P, Rusko H, et al. Neuromuscular function and mechanical efficiency of human leg extensor muscles during jumping exercises. Acta Physiol Scand. 1982;114:543–50. doi: 10.1111/j.1748-1716.1982.tb07022.x 7136782
5. Komi PV. Relevance of in vivo force measurements to human biomechanics. J Biomech. 1990;23(SUPPL. 1):23–34.
6. Gollhofer A, Komi PV, Fujitsuka N, Miyashita M. Fatigue during stretch-shortening cycle exercises. Int J Sports Med. 1987;8:38–47. 3583519
7. Kuitunen S, Komi P V, Kyröläinen H. Knee and ankle joint stiffness in sprint running. Med Sci Sports Exerc. 2002;34(1):166–73. doi: 10.1097/00005768-200201000-00025 11782663
8. Harrison AJ, Gaffney SD. Effects of muscle damage on stretch-shortening cycle function and muscle stiffness control. J Strength Cond Res. 2004;18:771–6. 15574081
9. Hobara H, Inoue K, Gomi K, Sakamoto M, Muraoka T, I S. Continuous change in spring-mass characteristics during a 400 m sprint. J Sci Med Sport. 2010;13(2):256–61. doi: 10.1016/j.jsams.2009.02.002 19342299
10. Debenham JR, Gibson WI, Travers MJ, Campbell AC, Allison GT. Modulation of stretch-shortening-cycle behavior with eccentric loading of triceps surae: A possible therapeutic mechanism. J Sport Rehabil. 2017 Mar;26(2):151–8. doi: 10.1123/jsr.2015-0129 27632850
11. Paavolainen LM, Nummela AT, Rusko HK. Neuromuscular characteristics and muscle power as determinants of 5-km running performance. Med Sci Sports Exerc. 1999;31(1):124–30. doi: 10.1097/00005768-199901000-00020 9927020
12. Comyns T.M., Harrison AJ, Hennessy L, Jensen RL. Identifying the optimal resistive load for complex training in male rugby players. Sport Biomech. 2007;6:59–70.
13. Hannah J, Hillier MJ. Applied Mechanics. England: Longman; 1995.
14. Zatsiorsky V, Prilutsky B. Biomechanics of Skeletal Muscles. Champaign, IL.: Human Kinetics; 2012.
15. Arampatzis A, De Monte G, Karamanidis K, Morey-Klapsing G, Stafilidis S, Brüggemann G-P. Influence of the muscle-tendon unit’s mechanical and morphological properties on running economy. J Exp Biol. 2006;209(17):3345–57.
16. Dumke CL, Pfaffenroth CM, McBride JM, McCauley GO. Relationship between muscle strength, power and stiffness and running economy in trained male runners. Int J Sports Physiol Perform. 2010;5(2):249–61. doi: 10.1123/ijspp.5.2.249 20625197
17. Pruyn EC, Watsford M, Murphy A. The relationship between lower-body stiffness and dynamic performance. Appl Physiol Nutr Metab. 2014;39(10):1144–50. doi: 10.1139/apnm-2014-0063 25007238
18. Hamill J, Moses M, Seay J. Lower extremity joint stiffness in runners with low back pain. Res Sport Med. 2009;17(4):260–73.
19. Flanagan EP, Harrison AJ. Muscle dynamics differences between legs in healthy adults. J Strength Cond Res. 2007;21:67–72. doi: 10.1519/00124278-200702000-00013 17313262
20. Hobara H, Kanosue K, Suzuki S. Changes in muscle activity with increase in leg stiffness during hopping. Neurosci Lett. 2007;418(1):55–9. doi: 10.1016/j.neulet.2007.02.064 17367931
21. Hobara H, Inoue K, Muraoka T, Omuro K, Sakamoto M, Kanosue K. Leg stiffness adjustment for a range of hopping frequencies in humans. J Biomech. 2010;43(3):506–11. doi: 10.1016/j.jbiomech.2009.09.040 19879582
22. Diggin D, Anderson R, Harrison AJ. An examination of the true reliability of lower limb stiffness measures during overground hopping. J Appl Biomech. 2016;32(3):278–86. doi: 10.1123/jab.2015-0210 26745354
23. Joseph CW, Bradshaw EJ, Kemp J, Clark RA. The interday reliability of ankle, knee, leg, and vertical musculoskeletal stiffness during hopping and overground running. J Appl Biomech. 2013 Aug;29(4):386–94. doi: 10.1123/jab.29.4.386 22923423
24. Van Emmerik REA, Miller R & Hammill J. Dynamical systems analysis of coordination. In: Research Methods in Biomechanics. 2014. p. 291–316.
25. Harrison AJ, Keane SP, Coglan J. Force-velocity relationship and stretch-shortening cycle function in sprint and endurance athletes. J Strength Cond Res. 2004;18(3):473–9. 15320647
26. Kyröläinen H, Komi PV. Mechanical efficiency of stretch-shorten cycle exercise. In: Komi PV, editor. Neuromuscular Aspects of Sports Performance. West Sussex, UK: Wiley-Blackwell; 2011. p. 103–14.
27. Kramer A, Ritzmann R, Gollhofer A, Gehring D, Gruber M. A new sledge jump system that allows almost natural reactive jumps. J Biomech. 2010;43(14):2672–7. doi: 10.1016/j.jbiomech.2010.06.027 20643409
28. Komi PV, Kaneko M, Aura O. EMG activity of the leg extensor muscles with special reference to mechanical efficiency in concentric and eccentric exercise. Int J Sports Med. 1987 Mar 14;8(S1):S22–9.
29. Furlong L-AM, Harrison AJ. Reliability and consistency of plantarflexor stretch-shortening cycle function using an adapted force sledge apparatus. Physiol Meas. 2013 Apr 1;34(4):437–48. doi: 10.1088/0967-3334/34/4/437 23524578
30. Maloney SJ, Fletcher IM. Lower limb stiffness testing in athletic performance: A critical review. Sport Biomech. 2018 May 16;1–22.
31. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sport Med. 1998;26(4):217–38.
32. McLachlan KA, Murphy AJ, Watsford ML, Rees S. The interday reliability of leg and ankle musculotendinous stiffness measures. J Appl Biomech. 2006;22(4):296–304. doi: 10.1123/jab.22.4.296 17293626
33. Granata KP, Wilson SE, Padua DA. Gender differences in active musculoskeletal stiffness. Part II. Quantification of leg stiffness during functional hopping tasks. J Electromyogr Kinesiol. 2002;12(2):127–35. doi: 10.1016/s1050-6411(02)00003-2 11955985
34. Padua DA, Arnold BL, Perrin DH, Gansneder BM, Carcia CR, Granata KP. Fatigue, vertical leg stiffness, and stiffness control strategies in males and females. J Athl Train. 2006;41(3):294–304. 17043698
35. Whittlesey SN & Robertson G. Two-dimensional inverse dynamics. In: Robertson G, Caldwell GE, Hammill J, Kamen G, Whittlesey SN, editors. Research Methods in Biomechanics. 2nd ed. Champaign, IL.: (Human Kinetics); 2014.
36. Winter D. Biomechanics and motor control of human movement. John Wiley & Sons, Toronto, Canada.; 2009.
37. Stefanyshyn D, Nigg B. Contribution of the lower extremity joints to mechanical energy in running vertical jumps and running long jumps. J Sport Sci. 1998;16:177–86.
38. Dempster W. Space requirements of the seated operator, geometrical, kinematic, and mechanical aspects of the body with special reference to the limbs. Wright-Patterson Air Force Base, Ohio; 1955.
39. Arampatzis A, Brüggemann G-P, Metzler V. The effect of speed on leg stiffness and joint kinematics in human racing. J Biomech. 1999;32:1349–53. doi: 10.1016/s0021-9290(99)00133-5 10569714
40. Coleman DR, Cannavan D, Horne S, Blazevich AJ. Leg stiffness in human running: Comparison of estimates derived from previously published models to direct kinematic-kinetic measures. J Biomech. 2012;45(11):1987–91. doi: 10.1016/j.jbiomech.2012.05.010 22682258
41. Hopkins WG. Measures of reliability in sports medicine and science. Sport Med. 2000;30:1–15.
42. Weir JP. Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res. 2005;19:231–40. 15705040
43. Vincent W, Weir JP. Statistics in kinesiology. Fourth. Champaign, IL.: Human Kinetics; 1994.
44. Cohen J. A power primer. Psychol Bull. 1992;112:155–9. doi: 10.1037//0033-2909.112.1.155 19565683
45. Farley CT, Houdijk HH, Van Strien C, Louie M. Mechanism of leg stiffness adjustment for hopping on surfaces of different stiffnesses. J Appl Physiol. 1998;85(3):1044–55. doi: 10.1152/jappl.1998.85.3.1044 9729582
46. Farley CT, Morgenroth DC. Leg stiffness primarily depends on ankle stiffness during human hopping. J Biomech. 1999;32(3):267–73. doi: 10.1016/s0021-9290(98)00170-5 10093026
47. Whittlesey SN, Hamill J. Computer simulation of human movement. In: Robertson G, Caldwell GE, Hammill J, Kamen G, Whittlesey SN, editors. Research Methods in Biomechanics. 2nd ed. Champaign, IL.: (Human Kinetics); 2014. p. 233–46.
48. Kramer A, Ritzmann R, Gruber M, Gollhofer A. Four weeks of training in a sledge jump system improved the jump pattern to almost natural reactive jumps. Eur J Appl Physiol. 2012;112(1):285–93. doi: 10.1007/s00421-011-1981-5 21544569
Článok vyšiel v časopise
PLOS One
2019 Číslo 12
- Metamizol jako analgetikum první volby: kdy, pro koho, jak a proč?
- Nejasný stín na plicích – kazuistika
- Masturbační chování žen v ČR − dotazníková studie
- Úspěšná resuscitativní thorakotomie v přednemocniční neodkladné péči
- Fixní kombinace paracetamol/kodein nabízí synergické analgetické účinky
Najčítanejšie v tomto čísle
- Methylsulfonylmethane increases osteogenesis and regulates the mineralization of the matrix by transglutaminase 2 in SHED cells
- Oregano powder reduces Streptococcus and increases SCFA concentration in a mixed bacterial culture assay
- The characteristic of patulous eustachian tube patients diagnosed by the JOS diagnostic criteria
- Parametric CAD modeling for open source scientific hardware: Comparing OpenSCAD and FreeCAD Python scripts